Omada L3 Campus Stackable Managed Switch User Manual

Omada L3 Campus Stackable Managed Switch

L3 Campus Stackable Managed Switch

Specificații

  • Model: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • Indicație LED:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      corect)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Instrucțiuni de utilizare a produsului

Capitolul 2: Instalare

Înainte de a începe procesul de instalare, asigurați-vă că aveți toate
the necessary tools and follow safety precautions.

  • Continutul pachetului: Check all items mentioned in
    pachetul.
  • Măsuri de siguranță: Follow the guidelines to
    asigura o instalare sigura.
  • Instrumente de instalare: Gather all tools required
    pentru instalare.
  • Instalarea produsului: Urmați pas cu pas
    instructions provided in the manual for successful
    instalare.

Capitolul 3: Conexiune

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Capitolul 4: Configurare

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
nevoi.

FAQ

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
secțiunea din manual pentru asistență suplimentară.

Loading PDF…
Download PDF

Soluție Business Networking
Ghid de instalare
Omada C.ampus Stackable L3 Managed Switch

Despre acest Ghid de instalare
Acest Ghid de instalare descrie caracteristicile hardware, metodele de instalare și punctele care trebuie luate în considerare în timpul instalării. Acest Ghid de instalare este structurat după cum urmează: Capitolul 1 Introducere Acest capitol descrie componentele externe ale switch-ului. Capitolul 2 Instalare Acest capitol ilustrează modul de instalare a switch-ului. Capitolul 3 Conexiune Acest capitol ilustrează modul de conectare fizică a switch-ului. Capitolul 4 Configurare Acest capitol ilustrează modul de configurare a switch-ului. Anexa A Depanare Anexa B Specificații

Public

Acest Ghid de instalare este destinat:

Inginer de rețea

Administrator de rețea

Convenții
· Este posibil ca unele modele prezentate în acest ghid să nu fie disponibile în țara sau regiunea dvs. Pentru informații despre vânzările locale, vizitați https://www.omadanetworks.com/.
· Cifrele din Capitolul 2, Capitolul 3 și Capitolul 4 sunt doar în scop demonstrativ. Comutatorul dvs. poate diferi ca aspect față de cel descris.
· Calculele bugetului PoE se bazează pe teste de laborator. Bugetul real de putere PoE nu este garantat și va varia ca urmare a limitărilor clientului și a factorilor de mediu.
· Acest ghid folosește formatele specifice pentru a evidenția mesajele speciale. Următorul tabel listează pictogramele de notificare care sunt utilizate în acest ghid.

Amintește-ți să fii atent. O atenție indică un potențial care poate duce la deteriorarea dispozitivului.
Amintiți-vă să luați cunoștință. Nota conține informații utile pentru o mai bună utilizare a produsului.

Document asociat
Ghidul utilizatorului și Ghidul de referință CLI al produsului sunt furnizate în Centrul de descărcare. Pentru a obține cele mai recente informații despre produs, vizitați oficialul website: https://support.omadanetworks.com/document/.

Cuprins
Capitolul 1 Introducere ———————- 01
1.1 Produs terminatview ……………………………………………………..01 1.2 Aspect………………………………………………………………..01
Capitolul 2 Instalare ————————- 12
2.1 Conținutul pachetului …………………………………………………….12 2.2 Măsuri de siguranță ………………………………………………12 2.3 Unelte de instalare……………………………………………………..14 2.4 Instalarea produsului ………………………………………………..14
Capitolul 3 Conexiune ————————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Capitolul 4 Configurare ——————– 27
4.1 Configurare terminatăview………………………………………………27 4.2 Mod independent……………………………………………………27 4.3 Mod controler……………………………………………………28
Anexa A Depanare —————- 32
Anexa B Specificații —————— 33

Omada C.ampus Stackable L3 Managed Switch

Capitolul 1 Introducere

1.1 Produs terminatview
Conceput pentru întreprinderi și companiiampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampfișierele includ alimentarea camerelor de rețea, puncte de acces LAN fără fir, telefoane IP, hub-uri de rețea, computere încorporate etc.
1.2 Aspect
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Buton de selectare a modului
Port de management

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Buton de selectare a modului
Port de management

LED

Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

Introducere 01

Omada C.ampus Stackable L3 Managed Switch

Indicație LED

PWR1*

PWR2

Verde aprins

Oprit

Verde aprins

Galben aprins**

Oprit

Verde aprins

Oprit

Oprit

Indicaţie
Comutatorul este alimentat de PWR1. PWR2 este deconectat sau funcționează incorect.
Comutatorul este alimentat de PWR1. PWR1 și PWR2 sunt conectate.*
Comutatorul este alimentat de PWR2. PWR1 este deconectat sau funcționează incorect.
Comutatorul este oprit sau ambele PWR1 și PWR2 funcționează necorespunzător.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Când LED-ul STK este aprins)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Indicaţie
Clipește: Comutatorul funcționează corect. Pornit sau oprit: Comutatorul funcționează incorect.
Verde Pornit: Toate ventilatoarele funcționează corect. Galben aprins: Nu toate ventilatoarele funcționează corect.
Aprins: Un dispozitiv este conectat la port. Clipește: Transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la port.
Pornit: Dispozitivul funcționează ca comutator principal în topologia stivă sau funcționează individual. Oprit: Dispozitivul funcționează ca comutator membru în topologia stivă.
Verde pornit: rulează la 1000 Mbps, dar fără activitate. Verde intermitent: rulează la 1000 Mbps și transmite sau primește date. Galben aprins: rulează la 10 Mbps/100 Mbps, dar fără activitate. Galben intermitent: rulează la 10 Mbps/100 Mbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.
Activat: numărul portului indică ID-ul unității în topologia stivei.
Verde pornit: rulează la 10 Gbps, dar fără activitate. Verde intermitent: rulează la 10 Gbps și transmite sau primește date. Galben aprins: rulează la 1 Gbps, dar fără activitate. Galben intermitent: rulează la 1 Gbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Când ambele PWR1 și PWR2 funcționează corect și comutatorul este alimentat de PWR1, este nevoie de 10-20 de secunde pentru ca LED-ul PWR2 (galben) să se stingă după ce PWR2 este deconectat.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Introducere

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Buton de selectare a modului
Port de management
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

Panoul frontal al S6500-48GP6XF este prezentat în figura următoare.

Buton de selectare a modului
Port de management
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 1G RJ45

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Buton de selectare a modului
Port de management
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Buton de selectare a modului
Port de management
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

Introducere 03

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Buton de selectare a modului
Port de management

LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Buton de selectare a modului
Port de management
LED Console Port USB2.0 Port (Type-C/RJ45)

Port 2.5G RJ45

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Indicaţie
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Clipește: Comutatorul funcționează corect. Pornit sau oprit: Comutatorul funcționează incorect.
Verde Pornit: Toate ventilatoarele funcționează corect. Galben aprins: Nu toate ventilatoarele funcționează corect.
Pornit: puterea PoE rămasă este de 7 W. Clipește: puterea PoE rămasă păstrează 7 W după ce acest LED este aprins timp de 2 minute. Oprit: puterea PoE rămasă este > 7 W.
Aprins: Un dispozitiv este conectat la port. Clipește: Transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la port.
Pornit: Dispozitivul funcționează ca comutator principal în topologia stivă sau funcționează individual. Oprit: Dispozitivul funcționează ca comutator membru în topologia stivă.

04 Introducere

Omada C.ampus Stackable L3 Managed Switch

LED

Indicaţie

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Verde pornit: rulează la 1000 Mbps, dar fără activitate. Verde intermitent: rulează la 1000 Mbps și transmite sau primește date. Galben aprins: rulează la 10 Mbps/100 Mbps, dar fără activitate. Galben intermitent: rulează la 10 Mbps/100 Mbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Când LED-ul STK este aprins)

Activat: numărul portului indică ID-ul unității în topologia stivei.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Când LED-ul PoE este aprins)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Verde pornit: rulează la 10 Gbps, dar fără activitate. Verde intermitent: rulează la 10 Gbps și transmite sau primește date. Galben aprins: rulează la 1 Gbps, dar fără activitate. Galben intermitent: rulează la 1 Gbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Verde Aprins: Funcționează la 25 Gbps, dar fără activitate. Verde Intermitent: Funcționează la 25 Gbps și transmite sau primește date. Galben Aprins: Funcționează la 1 Gbps/10 Gbps, dar fără activitate. Galben Intermitent: Funcționează la 1 Gbps/10 Gbps și transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la portul corespunzător.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Introducere 05

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Port de management

LED

Console Port USB3.0 Port

(RJ45/Tip C)

Selectarea modului

Buton

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Buton de selectare a modului
Port de management
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Port de management

LED

Port USB3.0

Port de consolă

(RJ45/Tip C)

Buton de selectare a modului

Slot SFP25 28G

LED

(Port 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

Slot 100G QSFP28 (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Introducere

Slot 100G QSFP28 (Port 49-56)

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Buton de selectare a modului
LED portul de management
Port USB3.0

Console Port (Type-C/RJ45)

Slot QSFP100 28G

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
VENTILATOR SYS
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Când LED-ul SPD este aprins)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Indicaţie
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Clipește: Comutatorul funcționează corect. Pornit sau oprit: Comutatorul funcționează incorect.
Verde: Toate ventilatoarele funcționează corect. Galben: Nu toate ventilatoarele funcționează corect.
Aprins: Un dispozitiv este conectat la port. Clipește: Transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la port.
Nota:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Pornit: Dispozitivul funcționează ca comutator principal în topologia stivă sau funcționează individual. Oprit: Dispozitivul funcționează ca comutator membru în topologia stivă.
Verde pornit: rulează la 10 Gbps, dar fără activitate. Verde intermitent: rulează la 10 Gbps și transmite sau primește date. Galben aprins: rulează la 1 Gbps, dar fără activitate. Galben intermitent: rulează la 1 Gbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.
Verde Aprins: Funcționează la 25 Gbps, dar fără activitate. Verde Intermitent: Funcționează la 25 Gbps și transmite sau primește date. Galben Aprins: Funcționează la 1 Gbps/10 Gbps, dar fără activitate. Galben Intermitent: Funcționează la 1 Gbps/10 Gbps și transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la portul corespunzător.

Introducere 07

Omada C.ampus Stackable L3 Managed Switch

LED

Indicaţie

Port 27-32 of S7500-26XF6Y ***
(Când LED-ul SPD este aprins)

Verde Aprins: Funcționează la 25 Gbps, dar fără activitate. Verde Intermitent: Funcționează la 25 Gbps și transmite sau primește date. Galben Aprins: Funcționează la 1 Gbps/10 Gbps, dar fără activitate. Galben Intermitent: Funcționează la 1 Gbps/10 Gbps și transmite sau primește date. Stins: Niciun dispozitiv nu este conectat la portul corespunzător.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Verde pornit: rulează la 100 Gbps, dar fără activitate. Verde intermitent: rulează la 100 Gbps și transmite sau primește date. Galben aprins: rulează la 40 Gbps, dar fără activitate. Galben intermitent: rulează la 40 Gbps și transmite sau primește date. Oprit: Niciun dispozitiv nu este conectat la portul corespunzător.
Nota:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Când LED-ul STK este aprins)

Activat: numărul portului indică ID-ul unității în topologia stivei.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port de administrare Conceput pentru a conecta dispozitivul pentru administrare prin web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Introducere

Omada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Model

1000 M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Slot

Slot

Port

Port Port

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Notă: PWR1 este sursa de alimentare primară și are prioritate față de PWR2.

Introducere 09

Omada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Slot de securitate Kensington

LED

Terminalul de împământare

Modul de alimentare

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Terminalul de împământare

LED

Power Supply Module Locking Strap Slot

LED

Slot de securitate Kensington

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

Panoul din spate al S7500-48Y8C este prezentat în figura următoare. Figura este doar cu titlu demonstrativ. Comutatorul dumneavoastră poate diferi ca aspect față de cel ilustrat.

Terminalul de împământare

LED

LED

Curea de blocare

Slot

Modul de alimentare

10 Introducere

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED LED
Locking Strap Slot
Modul de alimentare Slot de securitate Kensington

Terminalul de împământare

LED
Locking Strap Slot

Modul de alimentare

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Introducere 11

Omada C.ampus Stackable L3 Managed Switch

Capitolul 2 Instalare

2.1 Conținutul pachetului

Asigurați-vă că pachetul conține următoarele articole. Vă rugăm să contactați distribuitorul dumneavoastră, dacă vreunul dintre articolele enumerate este deteriorat sau lipsește. Cifrele sunt doar pentru demonstrație. Articolele reale pot diferi ca aspect și cantitate de cele prezentate.

Comutator

Cablu de alimentare și cablu de consolă

Ghid de instalare
Soluție Business Networking
Ghid de instalare
Omada C.ampus Stackable L3 Managed Switch

Suporturi de montare, șuruburi și picioare din cauciuc

2.2 Măsuri de siguranță
Pentru a evita orice deteriorare a dispozitivului și vătămare corporală cauzată de o utilizare necorespunzătoare, trebuie să respectați următoarele reguli.
Măsuri de siguranță Întrerupeți alimentarea în timpul instalării. Purtați o curea de mână anti-descărcare electrostatică și asigurați-vă că aceasta are un contact bun cu pielea și este
bine împământat. Folosiți doar cablul de alimentare furnizat împreună cu întrerupătorul. Asigurați-vă că tensiunea de alimentaretage se potrivește cu specificațiile indicate pe panoul din spate al
comutator. Asigurați-vă că întrerupătorul este instalat într-un mediu bine ventilat și că orificiul său de ventilație nu este
blocat. Nu deschideți și nu îndepărtați capacul comutatorului. Înainte de a curăța dispozitivul, întrerupeți alimentarea cu energie electrică. Nu-l curățați cu cârpa apoasă și niciodată
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Cerințele site-ului
Temperatura/Umiditatea

12 Instalare

Omada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Praful acumulat pe comutator poate fi absorbit de electricitatea statică și poate duce la un contact slab al punctelor de contact metalice. Au fost luate unele măsuri pentru ca dispozitivul să prevină electricitatea statică, dar electricitatea statică prea puternică poate provoca daune mortale elementelor electronice de pe placa de circuite internă. Pentru a evita efectul electricității statice asupra funcționării comutatorului, acordați o mare importanță următoarelor elemente: Eliminați praful dispozitivului în mod regulat și păstrați aerul din interior curat. Păstrați dispozitivul bine împământat și asigurați-vă că electricitatea statică a fost transferată. Interferențe electromagnetice
Elementele electronice, inclusiv capacitatea și inductanța de pe dispozitiv, pot fi afectate de interferențe externe, cum ar fi emisia condusă prin cuplarea capacității, cuplarea inductanței și cuplarea impedanței. Pentru a reduce interferențele, asigurați-vă că luați următoarele măsuri: Utilizați sursa de alimentare care poate filtra eficient interferențele din rețeaua de alimentare. Țineți dispozitivul departe de dispozitivele de înaltă frecvență și curent puternic, cum ar fi transmisia radio
statie. Folosiți ecranare electromagnetică atunci când este necesar. Protecție împotriva trăsnetului
Instalare 13

Omada C.ampus Stackable L3 Managed Switch
Vol. extrem de maretagCurenții pot fi produși instantaneu atunci când apar fulgere, iar aerul din calea de descărcare electrică poate fi încălzit instantaneu până la 20,000 °C. Deoarece acest curent instantaneu este suficient de puternic pentru a deteriora dispozitivele electronice, ar trebui luate măsuri mai eficiente de protecție împotriva trăsnetului. Asigurați-vă că rack-ul și dispozitivul sunt bine împământate. Asigurați-vă că priza are un contact bun cu pământul. Păstrați un sistem de cablare rezonabil și evitați fulgerele induse. Utilizați semnalul SPD (Dispozitiv de protecție la supratensiune) când faceți cablarea în exterior.
Notă: Pentru măsuri detaliate de protecție împotriva trăsnetworks, consultați Ghidul de protecție împotriva trăsnetworks de la adresa: https://support.omadanetworks.com/r/1004/. Locul de instalare
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Instrumente de instalare
Șurubelniță Phillips Cabluri pentru împachetarea ESD
Notă: Aceste instrumente nu sunt incluse cu produsul nostru. Dacă este necesar, le puteți achiziționa separat.
2.4 Instalarea produsului
Comutatorul este proiectat cu funcția de disipare a căldurii din față în spate. Când funcționează, aerul circulă așa cum se arată mai jos. Pentru o mai bună disipare a căldurii, instalați dispozitivul într-un mediu bine ventilat și lăsați spații de 5 până la 10 cm în jurul dispozitivului.
14 Instalare

Figura 2-1

Circulația aerului

Omada C.ampus Stackable L3 Managed Switch

Instalare desktop

Pentru a instala dispozitivul pe desktop, urmați pașii:
1. Setați dispozitivul pe o suprafață plană suficient de puternică pentru a susține întreaga greutate a dispozitivului cu toate accesoriile.

2. Îndepărtați hârtiile adezive de pe picioarele de cauciuc.

3. Atașați picioarele de cauciuc la partea inferioară a dispozitivului pentru a preveni alunecarea când este plasat pe un desktop.

Figura 2-2

Instalare desktop

Picioare Partea inferioară a crestăturii dispozitivului

Instalare rack

Pachetul include 6 perechi de suporturi diferite de montare în rack, imaginile acestora sunt prezentate mai jos și pot diferi de produsele reale.

Figura 2-3

Suporturi de montare

Grupa 2 de găuri pentru șuruburi

Bracket D Bracket C Bracket B Bracket A

Grupa 1 de găuri pentru șuruburi
Grupa 3 de găuri pentru șuruburi

Paranteza F

Screw Hole Group 4-2 (for device with 420mm depth)

Grupa 5 de găuri pentru șuruburi

Șurub gaură

Grupa 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Paranteza E

Instalare 15

Omada C.ampus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Metodă

Demonstraţie

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Distanța dintre rafturi
(For device with a depth of 380mm)

Distanța dintre rafturi
(For device with a depth of 420mm)

Distanța dintre rafturi
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Instalare

Omada C.ampus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Pentru a instala dispozitivul, urmați instrucțiunile descrise mai jos:

1. Attach the M6 nuts to the racks.

Figura 2-4

Fixarea piulițelor M6

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Figura 2-5

Instalarea suporturilor pe rack-uri

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Instalare 17

Omada C.ampus Stackable L3 Managed Switch

Figura 2-6

Instalarea suporturilor pe comutator

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Figura 2-7

Instalarea switch-urilor pe rack-uri

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Instalare

Omada C.ampus Stackable L3 Managed Switch

Instalarea modulului de alimentare

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Figura 2-8

Aspectul modulului de alimentare

Conector cablu de alimentare CA
FAN

Clipuri de reținere

Mâner de extracție

LED

Locking Strap Slot Release Handle

Dacă trebuie să adăugați încă un modul de alimentare, urmați pașii:

1. Purtați o brățară cu protecție împotriva descărcărilor electrostatice și asigurați-vă că aceasta are un contact bun cu pielea și este bine împământată.

2. Apăsați mânerul de extragere al modulului cu o mână și țineți partea de jos a modulului cu cealaltă mână. Împingeți ușor modulul de-a lungul șinei de ghidare a slotului.

3. Eliberați mânerul de extracție pentru a fixa modulul de alimentare la locul său.

Figura 2-9

Instalarea modulului de alimentare

Eliberați mânerul

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Purtați o brățară cu protecție împotriva descărcărilor electrostatice și asigurați-vă că aceasta are un contact bun cu pielea și este bine împământată.
Instalare 19

Omada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Dacă trebuie să scoateți modulul de alimentare, urmați pașii:
1. Purtați o brățară cu protecție împotriva descărcărilor electrostatice și asigurați-vă că aceasta are un contact bun cu pielea și este bine împământată.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Instalarea modulului ventilatorului
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Figura 2-11 Aspectul modulului ventilator
LED

20 Instalare

Extraction Handle Retainer Clips Release Handle

Omada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
împământat. 2. Apăsați mânerul de extracție al modulului cu o mână și trageți de mâner până când
Modulul iese complet din șasiu.
Figura 2-12 Scoaterea unui modul de ventilator deteriorat
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instalare 21

Omada C.ampus Stackable L3 Managed Switch

Capitolul 3 Conexiune

3.1 Port Ethernet

Conectați un port Ethernet al comutatorului la computer prin cablu RJ45 așa cum se arată în figura următoare.

Figura 3-1

Conectarea portului RJ45

Portul RJ45

RJ45 prin cablu

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Figura 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Port de consolă
CLI (Command Line Interface) vă permite să gestionați switch-ul, astfel încât puteți încărca CLI după conectarea PC-urilor sau a terminalelor la portul consolei de pe switch printr-un cablu (este furnizat un cablu consolei RJ45, în timp ce cablul Type-C nu este furnizat).
Conectați portul de consolă RJ45 al dispozitivului la computer prin cablul consolei, așa cum se arată în figura următoare.

22 Conexiune

Figura 3-3

Conectarea portului de consolă (RJ45).

Omada C.ampus Stackable L3 Managed Switch

Conectați portul de consolă de tip C al dispozitivului la computer prin cablul de tip C (nu este furnizat), așa cum se arată în figura următoare.

Figura 3-4

Conectarea portului de consolă (USB).

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verificați instalarea
După finalizarea instalării, verificați următoarele elemente: Ar trebui să existe un spațiu liber de 5 până la 10 cm în jurul dispozitivului pentru ventilație și asigurați-vă că fluxul de aer
este adecvat. Voltage a sursei de alimentare îndeplinește cerința volumului de intraretage a dispozitivului. Priza de alimentare, dispozitivul și rack-ul sunt bine împământate. Dispozitivul este conectat corect la alte dispozitive din rețea.
Conexiunea 23

Omada C.ampus Stackable L3 Managed Switch

3.5 Pornire

Conectați conectorul mamă al cablului de alimentare furnizat în priza de alimentare a dispozitivului și conectați conectorul pozitiv la o priză, așa cum se arată în figura următoare. Asigurați-vă că voltage a sursei de alimentare îndeplinește cerința volumului de intraretage (100-240 V~ 50/60 Hz).

Figura 3-5

Conectarea la sursa de alimentare

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Inițializare
După ce dispozitivul este pornit, acesta începe autotestul la pornire. O serie de teste rulează automat pentru a asigura funcționarea corectă a dispozitivului. În acest timp, indicatorii LED vor răspunde în următoarea ordine:
1. Indicatorul LED PWR se aprinde tot timpul. LED-ul SYS și indicatoarele LED ale tuturor porturilor se sting.
2. După aproximativ un minut, LED-urile SYS și indicatoarele LED ale tuturor porturilor vor clipi momentan și apoi se vor stinge.
3. Câteva secunde mai târziu, indicatorul LED SYS va clipi, ceea ce reprezintă o inițializare reușită.
3.7 Topologia stivei
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Comutator

Model(e) compatibil(e)

Cantitate

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Conexiune

Omada C.ampus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Există trei structuri de topologie de stivă pentru diferite scenarii, vă rugăm să construiți topologia potrivită în funcție de nevoile dvs.:

1. Topologia în lanț: Topologia în lanț este relativ simplă și nu necesită conexiune prin cablu între prima și ultima unitate. Este potrivit pentru stivuirea pe distanțe lungi, dar fiabilitatea sa este relativ scăzută.

Figura 3-6

Topologie în lanț

Grupul de porturi de stivuire 2
Grupul de porturi de stivuire 1

2. Topologia inel: Topologia inel are o fiabilitate mai mare în comparație cu topologia în lanț. Când unul dintre lanțurile din topologia inel este deconectat, topologia inel devine o topologie în lanț, dar întregul sistem de stivă poate funcționa în continuare normal. Topologia inelă necesită conexiune prin cablu între prima și ultima unitate, deci nu este potrivită pentru stivuirea pe distanțe lungi.

Figura 3-7

Topologie inel

Grupul de porturi de stivuire 2

Grupul de porturi de stivuire 1

Conexiunea 25

Omada C.ampus Stackable L3 Managed Switch

3. Topologie stea: Topologia stea conectează comutatoarele la un comutator principal central, prin urmare, poate crește semnificativ rata de redirecționare a datelor între comutatoarele membre, oferind în același timp un management unificat.

Figura 3-8

Star Topologie

Grupul de porturi de stivuire 2

Grupul de porturi de stivuire 3

Grupul de porturi de stivuire 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Conexiune

Omada C.ampus Stackable L3 Managed Switch

Capitolul 4 Configurare

4.1 Configurare terminatăview
Comutatorul acceptă două opțiuni de configurare:
Modul autonom: Configurați și gestionați comutatorul individual. Modul controler: Configurați și gestionați centralizat dispozitivele de rețea. Este recomandat în
rețea la scară largă, care constă din dispozitive de masă, cum ar fi puncte de acces, switch-uri și gateway-uri.
Notă: Când comutatorul este schimbat din modul autonom în modul controler, configurațiile comutatorului se vor pierde. Pentru detalii, consultați documentele aferente din centrul de descărcare al oficialului nostru website: https://support.omadanetworks.com/product/.

4.2 Mod autonom

În modul Standalone, utilizați un computer pentru a configura și gestiona comutatorul folosind GUI (Graphical User Interface) sau CLI (interfață de linie de comandă).

Figura 4-1

Topologie pentru modul Standalone

Comutator

PC

Folosind GUI
1. Pentru a accesa pagina de gestionare a comutatorului, asigurați-vă că comutatorul și computerul se află în aceeași subrețea. Deschideți un browser și tastați adresa IP a comutatorului în câmpul de adresă, apoi apăsați tasta Enter.
Dacă switch-ul obține adresa IP de la serverul DHCP (de obicei un gateway), găsiți adresa IP a switch-ului pe serverul DHCP.
Dacă nu, utilizați adresa IP implicită 192.168.0.1 pentru a lansa pagina de gestionare a comutatorului.

2. Prima dată când vă conectați, setați numele de utilizator și parola pentru a vă proteja mai bine rețeaua și dispozitivele. După aceea, sistemul vă va redirecționa automat înapoi la interfața de conectare pentru a vă autentifica cu datele de autentificare nou create.

3. După o autentificare reușită, va apărea pagina principală. Puteți face clic pe meniurile din partea de sus și din partea stângă pentru a configura funcțiile corespunzătoare.
Pentru configurațiile detaliate, consultați Ghidul utilizatorului și Ghidul CLI. Ghidurile pot fi găsite în centrul de descărcare al oficialului nostru website: https://support.omadanetworks.com/product/.
Utilizarea CLI Configurați o conexiune Telnet sau SSH pentru a accesa comutatorul prin CLI.

Configurare 27

Omada C.ampus Stackable L3 Managed Switch

Utilizați portul de consolă pentru a accesa comutatorul. Când utilizați portul de consolă, porniți programul de emulare a terminalului (cum ar fi Hyper Terminal) pe computer și configurați programul de emulare a terminalului după cum urmează:

Rata baud 38400 bps

Biți de date 8

Paritate Niciuna

Biți de oprire 1

Controlul fluxului Nici unul

Pentru configurațiile detaliate, consultați Ghidul utilizatorului și Ghidul CLI. Ghidurile pot fi găsite în centrul de descărcare al oficialului nostru website: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Modul controler
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Figura 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Comutator Gateway

Omada Pro Hardware Controller (C5300) EAP
28 Configurare

EAP

EAP

Clienții

Omada C.ampus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Găsiți adresa IP a gateway-ului. Deschideți linia de comandă pe PC și introduceți ipconfig. În lista de rezultate, găsiți Gateway-ul implicit, care este și adresa IP a gateway-ului.
2. Lansați a web browser și introduceți adresa IP a gateway-ului. Conectați-vă la contul gateway-ului web pagină. Apoi accesați Network > LAN > DHCP Client List pentru a găsi adresa IP a controlerului dvs. în funcție de adresa MAC.
3. Introduceți adresa IP a controlerului dumneavoastră în bara de adrese pentru a o deschide web pagină.
4. Pe controlerul Omada Pro web pagina, urmați expertul pentru a finaliza configurarea rapidă.
5. După configurarea rapidă, apare pagina de conectare. Introduceți numele de utilizator și parola pe care le-ați creat și faceți clic pe Conectare. Apoi puteți configura în continuare controlerul.
6. Dacă doriți să gestionați dispozitivele de la distanță, urmați pașii următori:
o. Asigurați-vă că Accesul la cloud este activat pe controlerul dvs. În mod implicit, Accesul în cloud este activat. Asigurați-vă că LED-ul Cloud clipește încet.

b. Lansați a web browser și introduceți https://omada.tplinkcloud.com în bara de adrese. Introduceți ID-ul și parola TP-Link pentru a vă conecta. Faceți clic pe + Adăugați controler și alegeți Controler hardware pentru a adăuga controlerul. Apoi puteți configura în continuare controlerul.

For more details, refer to the Installation Guide of C5300.

Prin Omada Pro Software Controller

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Figura 4-3

Gestionați rețeaua prin Omada Pro Software Controller

Poarta de acces

Comutator

Controlor

Controler software Omada Pro AP

AP

AP

rulează pe PC-ul gazdă

Clienții

Configurare 29

Omada C.ampus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web pagină. Dacă nu, faceți clic pe Lansați un browser pentru a gestiona rețeaua.
2. Pe controlerul Omada Pro web pagina, urmați expertul pentru a finaliza configurarea rapidă.
3. După configurarea rapidă, apare pagina de conectare. Introduceți numele de utilizator și parola pe care le-ați creat și faceți clic pe Conectare. Apoi puteți configura în continuare controlerul.
4. Dacă doriți să gestionați dispozitivele de la distanță, urmați pașii următori:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web pagina, accesați Setări > Acces la cloud pentru a activa Accesul la cloud și legați-vă ID-ul TP-Link. Dacă l-ați configurat în configurarea rapidă, săriți peste acest pas.
b. Lansați a web browser și introduceți https://omada.tplinkcloud.com în bara de adrese. Introduceți ID-ul dvs. TP-Link și parola pentru a vă conecta. Va apărea o listă de controlere care au fost legate cu ID-ul dvs. TP-Link. Apoi puteți face clic pe Lansare pentru a configura în continuare controlerul.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Prin controlerul bazat pe cloud Omada Pro

Controlerul bazat pe cloud Omada Pro este o alternativă bună fără a fi nevoie să instalați controlerul software pe un computer.

Licențele trebuie achiziționate suplimentar.

Figura 4-4

Gestionați rețeaua prin Omada Pro Cloud-Based Controller

Norul Omada

Poarta de acces

Comutator

AP

AP

AP

AP

Clienții
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser și introduceți https://omada.tplinkcloud.com în bara de adrese. Conectați-vă cu
your TP-Link ID.
30 Configurare

Omada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Puteți lansa controlerul pentru a adopta și gestiona dispozitive. * Aplicația Omada Cu aplicația Omada, puteți gestiona controlerul și la o locație locală sau la distanță prin intermediul dispozitivului mobil. Pentru configurațiile detaliate, consultați Ghidul utilizatorului al controlerului. Ghidul poate fi găsit în centrul de descărcare al site-ului nostru oficial. website: https://support.omadanetworks.com/product/.
Configurare 31

Omada C.ampus Stackable L3 Managed Switch
Anexa A Depanarea
Q1. Ce aș putea face dacă am uitat numele de utilizator și parola comutatorului?
1. Conectați portul de consolă al computerului la portul de consolă al comutatorului și deschideți un program de emulare a terminalului.
2. Opriți și reporniți comutatorul. Efectuați acțiunea indicată de programul de emulare a terminalului pentru a ajunge în meniul bootUtil. Acțiunea diferă de la produs la produs. Acțiunile posibile sunt enumerate mai jos: · Apăsați orice tastă pentru a opri pornirea automată. · Apăsați CTRL-B pentru a ajunge la meniul bootUtil.
3. Va fi afișat meniul bootUtil. Introduceți numărul 6 pentru a selecta opțiunea „Recuperare parolă” și introduceți Y pentru a șterge toți utilizatorii și parolele. Apoi puteți reseta numele de utilizator și parola.
Î2. De ce funcționează anormal LED-ul PWR? LED-ul PWR/Power ar trebui să fie aprins atunci când sistemul de alimentare funcționează normal. Dacă LED-ul PWR/Power a funcționat anormal, urmați pașii următori:
1. Asigurați-vă că este conectat corect cablul de alimentare și că contactul de alimentare este normal. 2. Asigurați-vă că tensiuneatage a sursei de alimentare îndeplinește cerința volumului de intraretage din
comutator.
Î3. Ce ar trebui să fac dacă nu pot accesa web pagina de administrare? Încercați următoarele:
1. Verificați fiecare LED de port de pe comutator și asigurați-vă că cablul Ethernet este conectat corect. 2. Încercați un alt port pe comutator și asigurați-vă că cablul Ethernet este adecvat și funcționează normal. 3. Opriți întrerupătorul și, după un timp, porniți-l din nou. 4. Asigurați-vă că adresa IP a computerului dvs. este setată în subrețeaua comutatorului. 5. Dacă tot nu puteți accesa pagina de configurare, resetați comutatorul la valorile implicite din fabrică. Apoi
adresa IP a computerului dvs. ar trebui să fie setată ca 192.168.0.x („x” este orice număr de la 2 la 254) și masca de subrețea ca 255.255.255.0.
Î4. De ce nu se afișează corect programul de emulare a terminalului? Încercați următoarele:
1. Asigurați-vă că sursa de alimentare este normală și că cablul consolei este conectat corect. 2. Verificați dacă cablul consolei este de tipul potrivit. 3. Asigurați-vă că parametrii programului de emulare a terminalului sunt corecti: configurați Biți pe secundă
ca 38400, Biții de date ca 8, Paritate ca Nici unul, Biții de oprire ca 1 și Controlul fluxului ca Nici unul.
32 Anexa A Depanare

Omada C.ampus Stackable L3 Managed Switch

Anexa B Specificații

Specifications for S6500 Series Switches

Articol

Conţinut

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Standarde

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Anexa B Specificații 33

Omada C.ampus Stackable L3 Managed Switch

Bugetul PoE

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Temperatura și altitudinea de funcționare

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Temperatura de depozitare -40 °C la 70 °C (-40 °F la 158 °F)

Umiditate de funcționare 10% până la 90% RH Fără condensare

Umiditatea de depozitare

5% până la 90% RH Fără condensare

34 Anexa B Specificații

Omada C.ampus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Articol

Conţinut

Standarde

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Temperatura și altitudinea de funcționare

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Temperatura de depozitare -40 °C la 70 °C (-40 °F la 158 °F)

Umiditate de funcționare 10% până la 90% RH Fără condensare

Umiditatea de depozitare

5% până la 90% RH Fără condensare

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Altitudinea acceptată este de la nivelul mării până la 5000 m. Trebuie reținut că atunci când altitudinea este peste 2000 m, pentru fiecare creștere a altitudinii de 220 de metri, temperatura maximă de funcționare va scădea cu 1°C (1.8°F).

Anexa B Specificații 35

Omada C.ampus Stackable L3 Managed Switch

Specificații pentru modulele de alimentare

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Intrare de putere

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Ieșire Voltage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Curent de ieșire

9.35 A (maxim)

16.5 A (maxim)

45 A (maxim)

Putere de ieșire

500 W (maxim)

900 W (maxim)

550 W (maxim)

Altitudine de operare

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Anexa B Specificații

Avertisment marcaj CE
Acesta este un produs de clasa A. Într-un mediu casnic, acest produs poate provoca interferențe radio, caz în care utilizatorului i se poate cere să ia măsurile adecvate.
Declarație de conformitate UE
TP-Link declară prin prezenta că switch-ul este în conformitate cu cerințele esențiale și alte prevederi relevante ale directivelor 2014/30/UE, 2014/35/UE, 2011/65/UE și (UE) 2015/863. ​​Declarația de conformitate UE originală poate fi găsită la https://www.tp-link.com/en/support/ce/
Declarația de conformitate din Marea Britanie
TP-Link declară prin prezenta că switch-ul este în conformitate cu cerințele esențiale și alte prevederi relevante ale Regulamentului privind compatibilitatea electromagnetică din 2016 și ale Regulamentului privind echipamentele electrice (siguranța) din 2016. Declarația de conformitate originală din Regatul Unit poate fi găsită la https://www.tp-link.com/support/ukca/
, .
ATENŢIE:
Dublu poli, fuziune neutră. Deconectați rețeaua înainte de întreținere.
Informații de siguranță
· Țineți aparatul departe de apă, foc, umiditate sau medii fierbinți. · Nu încercați să dezasamblați, să reparați sau să modificați dispozitivul. Dacă aveți nevoie de service, vă rugăm să ne contactați. · Așezați dispozitivul cu suprafața inferioară în jos. · Ștecherul de pe cablul de alimentare este folosit ca dispozitiv de deconectare, priza va fi
ușor accesibil. · Conectați produsul la prizele de perete cu împământare prin cablul de alimentare
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
baterii.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Vă rugăm să citiți și să urmați informațiile de siguranță de mai sus atunci când utilizați dispozitivul. Nu putem garanta că nu vor avea loc accidente sau daune din cauza utilizării necorespunzătoare a dispozitivului. Vă rugăm să utilizați acest produs cu grijă și să utilizați pe propriul risc.

Pentru asistență tehnică, ghiduri de utilizare și alte informații, vă rugăm să vizitați https://support.omadanetworks.com/ sau pur și simplu scanați codul QR.
© 2026 TP-Link 7100002759 REV2.0.1

Documente/Resurse

PDF thumbnailL3 Campus Stackable Managed Switch
User Manual · L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Pune o întrebare

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Pune o întrebare

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.