ED-PAC3020 EDATEC Automatizare și control industrial

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-PRODUCT

Specificații

  • Nume produs: ED-PAC3020
  • Producător: EDA Technology Co., Ltd
  • Data de lansare: 1 august 2025
  • Software de programare: CODESYS V3.5 SP19
  • Configurații de memorie: 2GB DDR + 128GB SSD or 8GB DDR + 256GB SSD
  • Interfețe: HDMI, USB, Ethernet, RS232, RS485

Instrucțiuni de utilizare a produsului

  1. Pesteview:
    1. The ED-PAC3020 is a real-time CODESYS programmable automation controller suitable for industrial control and IoT fields. It comes pre-installed with a multi-core CODESYS runtime and offers different memory configurations based on user requirements.
  2. Hardware:
    1. The device features commonly used interfaces such as HDMI, USB, Ethernet, RS232, and RS485. It integrates an RTC and supports connection to remote EtherCAT-based I/O modules.
  3. Introduction to CODESYS Software:
    1. The product supports CODESYS V3.5 SP19 and later versions for programming and control.
  4. Aplicație de rețea:
    1. The device offers EtherCAT, Ethernet, RS485, and RS232 interfaces for multi-layer network communication to meet diverse application requirements.

Panoul frontal:

  1. Port RS232: Folosit pentru conectarea echipamentelor de control de la terți.
  2. Green UART indicators: Check the communication status of UART port.
  3. Indicator roșu de alimentare: Indică starea de alimentare a dispozitivului.
  4. Green system status indicator: Shows system read/write operations status.
  5. Ieșire audio (HPO): Ieșire audio stereo.
  6. Intrare audio (LINE IN): Acceptă intrare audio stereo.
  7. RS-485 port: Used to connect third-party control equipment.
  8. Porturi USB 2.0: Acceptă o rată de transmisie de până la 480 Mbps.

Manual hardware

  • Acest capitol prezintă produsul pesteview, software CODESYS, aplicație de rețea, listă de pachete, aspect, butoane, indicatori și interfețe.

Pesteview

  • The ED-PAC3020 is a real-time CODESYS programmable automation controller, pre-installed by default with a multi-core CODESYS runtime. Depending on the application scenario and user requirements, it offers programmable logic system configurations with either 2GB DDR + 128GB SSD or 8GB DDR + 256GB SSD.

AVERTIZARE

  • The ED-PAC3020 device comes pre-installed with a valid CODESYS license by default. Reinstalling the operating system will invalidate the CODESYS license. Do not attempt to install the OS on your own.
  • ED-PAC3020 oferă interfețe utilizate în mod obișnuit, cum ar fi HDMI, USB, Ethernet, RS232 și RS485, integrează RTC și este utilizat în principal în domeniile controlului industrial și IoT.
  • The ED-PAC3020 supports connection to remote EtherCAT-based I/O modules (e.g., couplers, DI, DO, AI, AO) via an EtherCAT network.
  • The device integrates the CODESYS Control Runtime System, supporting IEC 61131-3 programming standards and industrial communication protocols like EtherCAT and Modbus TCP.

Users can optionally enable additional functionalities by licensing features such as:

  • TargetVisu
  • WebVisu Softmotion
  • CNC + Robotics
  • Maestru EtherCAT
  • Modbus TCP Master
  • Server OPC UAED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-1

Configurații personalizate sunt disponibile pentru a îndeplini cerințele specifice ale aplicației.

Introduction to CODESYS Software

  • CODESYS (Controller Development System) is an open industrial automation software development platform that provides a full-stack solution for programming, debugging, and maintaining programmable logic controllers (PLCs), industrial PCs (IPCs), and embedded control systems.
  • Compliant with the IEC 61131-3 international standard, it supports complex logic control, multi-axis motion control, industrial communication protocol integration, and real-time data processing.
  • It is widely used in smart manufacturing, energy management, logistics automation, and other industrial fields.

Caracteristici cheie ale CODESYS:

  • Standardized Programming Language Support
    • Full compatibility with the IEC 61131-3 programming languages:
      • Diagrama cu scară (LD)
      • Diagrama blocului funcțional (FBD)
      • Text structurat (ST)
      • Lista de instrucțiuni (IL)
      • Diagramă de funcții secvențiale (SFC)
    • Supports Object-Oriented Programming (OOP) extensions for large-scale complex projects.
  • Cross-Platform Development & Deployment
    • Development Environment: Compatible with Windows and Linux operating systems, offering a unified engineering interface.
    • Target Systems: Deployable on 2,000+ industrial controller hardware platforms, including ARM/X86 architectures.
  • Modular Engineering Libraries
    • Prebuilt Libraries: Include industrial protocol stacks (Modbus/TCP, OPC UA, EtherCAT) and advanced control modules (PID control, CNC interpolation algorithms).
    • Custom Libraries: Support encapsulation and reuse of Function Blocks and POUs (Program Organization Units).
  • Visual Debugging & Diagnostic Tools
    •  Real-time monitoring of variables, I/O mapping, and task execution status with waveform analysis.
    • Advanced debugging tools: breakpoints, step-by-step execution, and cross-referencing for rapid fault diagnosis.
    • Integrated HMI development tools for seamless SCADA system integration.
  • ED-PAC3020 este compatibil cu CODESYS V3.5 SP19 și versiunile ulterioare.

Aplicație de rețea

  • The ED-PAC3020 features EtherCAT, Ethernet, RS-485 and RS-232 interfaces, enabling multi-layer network communication to meet diverse application requirements across various scenarios. A typical application topology is illustrated in the figure below:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-2

Lista de ambalare

  • 1 x ED-PAC3020 Unit
  • 4 x Pads

Aspect

  • Introducing the functions and definitions of the interfaces on each panel.

Panoul frontal

Introducerea tipurilor de interfețe ale panoului frontal și a definițiilor acestora.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-3

NU. Funcţie Definiţie
  1 x RS232 port, 3-Pin 3.5mm pitch phoenix terminal, which is used to connect the third-party control

echipamente.

2 2 indicatori UART verzi, utilizați pentru a verifica starea comunicării portului UART.
3 1 x indicator roșu de alimentare, care este utilizat pentru a verifica starea dispozitivului pornit și oprit.
4 1 x indicator verde de stare a sistemului, care este utilizat pentru view starea operațiunilor de citire/scriere ale sistemului.
5 1 x Ieșire audio (HPO), conector jack audio de 3.5 mm (verde), ieșire audio stereo.
6 1 x Intrare audio (LINE IN), conector jack audio de 3.5 mm (roșu), acceptă intrare audio stereo.
 

7

1 x port RS485, terminal Phoenix cu 3 pini, pas de 3.5 mm, utilizat pentru conectarea echipamentelor de control terțe.
8 2 porturi USB 2.0, conector tip A, fiecare canal suportă o rată de transmisie de până la 480 Mbps.
9 2 porturi USB 3.0, conector tip A, fiecare canal suportă o rată de transmisie de până la 5 Gbps.
 

10

1 x Ethernet interface (10/100/1000M auto-negotiation), RJ45 connector, EtherCAT communication interface for connecting to EtherCAT networks, with PoE (Power over Ethernet) support.

Panoul din spate

  • Introducerea tipurilor și definițiilor de interfețe pentru panoul din spate.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-4
NU. Funcţie Definiţie
1 1 x buton de pornire, care este folosit pentru a porni și opri dispozitivul.
 

 

2

1 x slot pentru card Micro SD, rezervat pentru utilizare ulterioară.

Notă: Dispozitivul pornește implicit de pe SSD. Acest slot pentru card Micro SD este rezervat pentru potențiale expansiune.

Panoul lateral

  • Introducerea tipurilor de interfețe și definițiilor panoului lateral.

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-5

NU. Funcţie Definiţie
1 1 x intrare CC, conector USB tip C, care acceptă o alimentare de intrare de 5V 5A.
2 2 porturi HDMI, conector Micro HDMI, care poate conecta un ecran și acceptă 4K 60Hz

Buton

  • The ED-PAC3020 includes a ON/OFF button, and the silkscreen is “ON/OFF”. If you run Raspberry Pi Desktop, you can initiate a clean shutdown by briefly pressing the power button. A menu will appear asking whether you want to shutdown, reboot, or logout.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-6

SFAT

  • Dacă rulați Raspberry Pi Desktop, puteți apăsa butonul de pornire de două ori consecutiv pentru a opri.

Indicator

  • Această secțiune explică starea și semnificațiile indicatorilor integrați în dispozitivul ED-PAC3020.
​Indicator Stare Descriere
 

 

 

PWR

On Dispozitivul a fost pornit.
 

Clipi

Alimentarea cu energie a dispozitivului este anormală, vă rugăm să opriți imediat alimentarea cu energie.
Oprit Dispozitivul nu este pornit.
 

ACT

 

Clipi

The system started successfully and is reading and writing data.
​Indicator Stare Descriere
   

Oprit

The device is not powered on or does not read and write data.
COM1~COM2 Pornit/ Clipește Datele sunt transmise
 

Oprit

The device is not powered on or there is no data transmission.
Yellow indicator of Ethernet port On Conexiunea Ethernet este în stare normală.
Clipi The Ethernet connection is abnormal.
Oprit Conexiunea Ethernet nu este configurată.
Green indicator of Ethernet port On Conexiunea Ethernet este în stare normală.
Clipi Datele sunt transmise prin portul Ethernet.
Oprit Conexiunea Ethernet nu este configurată.

SFAT

  • Funcția indicatorului PWR/ACT de pe Raspberry Pi 5 a fost transferată în mod implicit la indicatorii separați PWR și ACT, astfel încât indicatorul PWR/ACT rămâne aprins după pornirea dispozitivului.

Interfață

  • Introducerea definiției și funcției fiecărei interfețe din produs.

Interfață de alimentare

  • Dispozitivul ED-PAC3020 include o interfață de intrare a alimentării, care utilizează un conector USB de tip C etichetat „PWR IN” și acceptă o intrare de alimentare de 5V 5A.

SFAT

  • Pentru ca Raspberry Pi 5 să obțină performanțe mai bune, se recomandă utilizarea unui adaptor de alimentare de 5V 5A.
  • 1.8.2 Interfață Ethernet 1000M (EtherCAT)
  • The ED-PAC3020 device includes one auto-negotiating 10/100/1000M Ethernet interface with an RJ45 connector featuring status LEDs, labeled as ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-7“. This interface serves as an EtherCAT communication port for connecting to EtherCAT networks and supports PoE (Power over Ethernet) power delivery.

Interfața HDMI

  • Dispozitivul ED-PAC3020 include 2 interfețe HDMI care utilizează conectori Micro HDMI, etichetați „HDMI”, pentru conectarea afișajelor HDMI. Aceste interfețe acceptă ieșire video de până la 4Kp60.

SFAT

  • Some third-party Micro HDMI cables may have shorter Micro HDMI connectors, which could cause connection issues. It is recommended to use the official Raspberry Pi Micro HDMI to Standard HDMI cable for optimal compatibility.

Interfață USB 2.0

  • The ED-PAC3020 device includes 2 USB 2.0 interfaces with standard Type-A connectors, labeled as “ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-8“. These interfaces support connecting standard USB 2.0 peripherals and offer a maximum transfer rate of 480Mbps.

Interfață USB 3.0

  • The ED-PAC3020 device includes 2 USB 3.0 interfaces with standard Type-A connectors, labeled as “ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-9 “. These interfaces support connecting standard USB 3.0 peripherals and offer a maximum transfer rate of 5Gbps.

Interfață RS232

  • The ED-PAC3020 device includes 1 RS232 interface with a 3-Pin 3.5mm pitch Phoenix terminal, labeled “TX/RX/GND”.

Definiția pinului

  • Pinii terminali sunt definiți după cum urmează:
ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-10

 

Pin ​ID Nume PIN
1 TX
2 RX
3 GND

Interfața RS232 corespunde următoarelor nume de pini de pe Pi5:

Semnal Pi5 GP​IO Name Pi5 Pin Afară
TX GPIO4 UART3_TXD
RX GPIO5 UART3_RXD

Schema de cablare a portului RS232 este următoarea:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-11

Interfață RS485

  • The ED-PAC3020 device includes 1 RS485 interface with a 3-Pin 3.5mm pitch Phoenix terminal, labeled “A/B/GND”.

Definiția pinului

  • Pinii terminali sunt definiți după cum urmează:
ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-12

 

Pin ​ID Nume PIN
1 A
2 B
3 GND

Interfața RS485 corespunde următoarelor nume de pini de pe Pi5:

Semnal Pi5 GP​IO Name Pi5 Pin Afară
A GPIO12 UART5_TXD
B GPIO13 UART5_RXD

Cabluri de conectare

  • Schema de cablare a portului RS485 este următoarea:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-13

Configurația rezistenței terminale RS485

  • The ED-PAC3020 device includes 1 RS485 interface.
  • A 120Ω termination resistor is reserved between the A and B lines of the RS485 circuit. Inserting a jumper cap enables this termination resistor.
  • By default, no jumper is installed, rendering the 120Ω termination resistor inactive. The termination resistor is located at J7 on the PCBA (printed circuit board assembly).

SFAT

  • The device case must be opened to inspect the 120Ω termination resistor.

Intrare audio

  • Dispozitivul ED-PAC3020 include 1 interfață de intrare audio (LINE IN), o mufă audio roșie de 3.5 mm, etichetată cu „ ”, care acceptă intrare stereo.

Ieșire audio

  • The ED-PAC3020 device includes 1 audio output interface (HPO), a green 3.5mm audio jack, labeled as ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-14“, which supports stereo output.

Instalarea dispozitivului

  • Dispozitivul ED-PAC3020 este conceput implicit pentru amplasarea pe birou și permite montarea pe perete cu suportul de perete opțional ED-ACCBKT-L3020 de la compania noastră.

SFAT

  • The ED-PAC3020 packaging box does not include the ED-ACCBKT-L3020 by default. Users must purchase it separately.

Preparare:

  • Prepared a Phillips-head screwdriver.
  • Obtained the ED-ACCBKT-L3020 wall-mount bracket.

Pas:

  1. Use a Phillips screwdriver to unscrew the four M2.5 screws on the side of the ED-IPC3020 counterclockwise.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-15
  2. Align the left and right brackets of the ED-ACCBKT-L3020 with the screw holes on both sides of the ED-PAC3020, insert the four M2.5*6 screws, and tighten them clockwise with a Phillips screwdriver to secure the ED-ACCBKT-L3020 to the sides of the ED-PAC3020.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-16
  3. Based on the spacing and diameter of the wall-mounting screw holes of the ED-ACCBKT-L3020 left and right brackets (refer to the diagram below), drill holes in the wall accordingly, then proceed with wall-mounted installation of the device.
    Unitate: mm
  4. Tolerance: 0.5-6±0.05, 6-30±0.1, 30-120±0.15

Dimensiune

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-17

Pornirea Dispozitivului

  • Acest capitol detaliază procedurile specifice pentru conectarea cablurilor și pornirea dispozitivului.

Cabluri de conectare

  • This section describes the procedures for connecting cables to the device.

Preparare:

  • Obtained fully functional accessories such as a switch, monitor, mouse, keyboard, I/O expansion module, and power adapter.
  • Available functional network connection.
  • Available functional cables: HDMI cable and Ethernet cable.

Schema schematică a cablurilor de conectare:

  • Please refer to 1.8 Interface for the pin definition of each interface and the specific method of wiring.

SFAT

  • Some third-party Micro HDMI cables may have shorter Micro HDMI connectors, which could cause connection issues. It is recommended to use the official Raspberry Pi Micro HDMI to Standard HDMI cable for optimal compatibility.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-18

Booting The System For The First Time

  • Once the ED-PAC3020 is connected to power, the system will begin to boot up.
  • Red PWR indicator: Lights up to indicate the device is receiving power.
  • Green ACT indicator: Blinks to signal normal system startup. The Raspberry Pi logo will then appear in the upper-left corner of the screen.

SFAT

  • The default username is pi, the default password is raspberry.

Sistem de operare Raspberry Pi (desktop)

  • Dacă dispozitivul este instalat din fabrică cu sistemul de operare Desktop, acesta va porni direct în interfața desktop la pornire, așa cum se arată în figura de mai jos.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-20

Sistemul de operare Raspberry Pi (Lite)

  • Dacă dispozitivul este instalat din fabrică cu sistemul de operare Lite, acesta se va conecta automat folosind datele de autentificare implicite după pornire. Figura de mai jos indică faptul că sistemul a pornit cu succes.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-21.

CODESYS Programming

  • Acest capitol detaliază operațiunile specifice implicate în utilizarea CODESYS.

AVERTIZARE

  • The ED-PAC3020 device comes pre-installed with a valid CODESYS license by default. Reinstalling the operating system will invalidate the CODESYS license. Do not attempt to install the OS on your own.
  • CODESYS Software Download and Installation

SFAT

  • The installed CODESYS IDE version must be 3.5.19 or higher, and the PC operating system must be Windows 10 or Windows 11 (64-bit recommended).
  • Download the installation package from the official CODESYS website. Descărcarea URL is https://store.codesys.com/de/ (https://store.codesys.com/de/).
  • SFAT
  • When downloading from the CODESYS official website pentru prima dată, trebuie mai întâi să vă înregistrați și să vă conectați la contul dvs.
  • Right-click the downloaded installer and select “Run as administrator” from the context menu. Click “Install” in the opened installation interface, and keep the default configuration during the installation process.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-22
  • After the installation is complete, click “Finish” to close the installation interface.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-23

Obtaining and Installing Device Description File

  • Înainte de a vă conecta la dispozitiv prin CODESYS, trebuie să descărcați și să instalați descrierea dispozitivului file primul.

Obtaining Device Description File

SFAT

  • The device’s default Ethernet port IP address is 192.168.0.100. To modify it, refer to Configuring Ethernet IP.

Preparare:

  • A CODESYS-authorized ED-PAC3020 is available.
  • A functional Ethernet cable is available.
  • A Windows PC is prepared, with its IP address configured to the same subnet as the device. For exampDe exemplu, dacă adresa IP a dispozitivului (port Ethernet 1000M) este 192.168.0.100, setați adresa IP a PC-ului la 192.168.0.99.

Pași:

  1. Connect the device’s Ethernet port to the PC via an Ethernet cable, then power on the device.
  2. Enter http://192.168.0.100:8100 in the PC’s web browser pentru a accesa interfața „Setări PLC”.
  3. In the “Device Info” section, click the “[Download] Device Description File” button to download the corresponding “.xml” format device description file.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-24

SFAT

  • Also available directly in the document ED-PAC3020 Device File (https://vip.123pan.cn/ 1826505135/17964309) .

Installing Device Description File

Preparare:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
  • An ED-PAC3020 device with a valid CODESYS license and its corresponding device description file.
  • Connect both the PC and ED-PAC3020 to the network, ensuring their IP addresses are within the same subnet.

Pași:

  • Double-click the CODESYS icon on the PC desktop to open the CODESYS software. From the menu bar, select “Tools” → “Device Repository”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-25
  • In the opened “Device Repository” pane, click “Install”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-26
  • In the pop-up “Install Device Description” pane, select the device description file care urmează să fie instalat și faceți clic pe „Deschidere” pentru a continua instalarea.
  • After successful installation, you can verify in the “Device Repository” that the device description file au fost adăugate cu succes.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-27

Installing Remote I/O Device Description File

Preparare:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
  • An ED-PAC3020 device with a valid CODESYS license.
  • The remote I/O device description files au fost descărcate de la: Descrierea I/O la distanță Files (https://vip.123pan.cn/1826505135/16632390).
  • Connect the PC, ED-PAC3020, and remote I/O devices to the same switch. Ensure that the IP addresses of the PC, ED-PAC3020, and remote I/O devices are within the same subnet.

Pași:

  1. Double-click the CODESYS icon on the PC desktop to open the CODESYS software. From the menu bar, select “Tools” → “Device Repository”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-28
  2. In the opened “Device Repository” pane, click “Install”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-29
  3. In the pop-up “Install Device Description” pane, select the I/O device decirption file care urmează să fie instalat și faceți clic pe „Deschidere” pentru a continua instalarea.
  4. After successful installation, you can verify in the “Device Repository” that the I/O device description file au fost adăugate cu succes.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-30

Configurare hardware

Preparare:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
    • Descrierea dispozitivului fileși descrierea dispozitivului I/O la distanță files have been installed. Connect the PC, ED-PAC3020, and remote I/O devices to the same switch. Ensure that the IP addresses of the PC, ED-PAC3020, and remote I/O devices are within the same subnet.

Create a New Project and Connect to the Device

Pași:

  • Power on the ED-PAC3020 and the remote I/O modules. Open the CODESYS software on the PC, select “File” → “New Project” in the menu bar to open the “New Project” pane, and create a standard project.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-31
  • Select the installed device description file și faceți clic pe „OK”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-32
  • Double-click the device, select “Scan Network” on the right, then choose the detected device from the scan results, and click “OK” to confirm.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-33

SFAT

  • If the device cannot be detected during scanning, manually enter the IP address in the target device settings to connect.
  • If a device login prompt appears, log in with your credentials (username and password) or follow the instructions to register a new account.\

As shown in the figure below, this indicates the device is successfully connected.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-34

Adding Remote I/O Modules

Pași:

  1. Right-click “Device” and select “Add Device” in the menu to add the EtherCAT Master.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-35
  2. Double-click on the EtherCAT Master device to set the source address (Select the EtherCAT port, which corresponds to the device’s eth0 port).ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-36
  3. Faceți clic pe ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-38 button to log in to the device. A successful login is shown in the figure below.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-37
  4. Click on the EtherCAT Master device, select “Scan for Devices” in the right-click menu, and copy all devices to the project after scanning is completed.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-39
  5. Faceți clic pe ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-40button to log out of the device.
  6. Double-click the slave device, configure the relevant parameters in the right-hand interface, enable “Expert settings”, select “Enable” under Select DC section, and select “Enable Sync0”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-41
  7. Faceți clic pe ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-38 button to download the program to the device, then click the  button to run it. As ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-60shown in the figure below, this indicates a successful operation.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-42

Programare

  • Următorul exampdemonstrează programare practică folosind un scenariu de codare specific.

Procesul de programare

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-43

Programare Example

  • Complete the development and debugging of a program for a timed blinking LED using a PNP-type 8-channel digital output (DO) module.

Preparare:

  • A standard project has been created.
  • Hardware configuration has been completed.
  • A 24V compact LED lamp has been connected to the first output port of the remote DO (Digital Output) module.

Pași

  • Double-click the DO module, select “Module I/O Mapping” → “Output” in the right-hand interface, and view adresele tuturor porturilor de ieșire. După cum este ilustrat mai jos, adresa primului port de ieșire este %QX18.0.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-44
  • Write the program code as follows:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-46 ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-47 ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-48
  • After completing the program, click ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-61” to compile it and ensure there are no errors.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-49
  • Click Login to download the program to the device, then click Run to observe the LED blinking every 0.5 seconds.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-50

Operare și întreținere

  • După descărcarea programului pe dispozitiv, puteți efectua operațiunile Executare și Oprire.
Stare Operațiuni
Rulați programul In the main menu of the software interface, click the Login  button.
Opriți programul In the main menu of the software interface, click the stop  button.

Configurarea sistemului

  • Acest capitol prezintă modul de configurare a sistemului.

AVERTIZARE

Installing Picocom Tool

  • In the Linux environment, you can use the picocom tool to debug the serial ports RS232 and RS485.
  • Execute the following command to install the picocom tool.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-52
  • 5.8.2 Configurarea RS232
    ED-PAC3020 conține o interfață RS232, portul COM și dispozitivul corespunzător. filesunt enumerate în tabelul de mai jos:
Număr of RS485 Porturi Corespunzător COM Port Corespunzător Dispozitiv File
1 COM2 /dev/com2
  • Input commands as needed to control external device.

Configuring RS485

  • The ED-PAC3020 contains 1 RS-485 interface, and its corresponding COM port and device filesunt enumerate în tabelul de mai jos:
Număr of RS485 Porturi Corespunzător COM Port Corespunzător Dispozitiv File
1 COM2 /dev/com2

Preparare:

The RS485 ports of ED-PAC3020 has been connected with external device. Steps:

  1. Execute the following command to open the serial port com2, and configure the serial port baud rate to 115200.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-53
  2. Input commands as needed to control external device.

Configurarea audio

  • Configurarea audio
  • CODESYS License Management
  • Dispozitivul ED-PAC3020 este preinstalat în mod implicit cu o licență CODESYS. Puteți crea copii de rezervă și restaura licența accesând interfața „Setări PLC”.

License Backup
Preparare:

  • A Windows PC has been set up with an IP address in the same subnet as the device. For exampDe exemplu, dacă adresa IP a dispozitivului (port Ethernet 1000M) este 192.168.0.100, setați adresa IP a PC-ului la 192.168.0.99.
  • A functioning Ethernet cable has been prepared.

Pași:

  • Connect the device’s 1000M Ethernet port to the PC via an Ethernet cable, then power on the device.
  • Enter http://192.168.0.100:8100 in the PC’s web browser pentru a accesa interfața „Setări PLC”.
  • In the “Codesys License Management” interface, click “Backup License” to download the license file și salvați-l local.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-56

SFAT

  • The backed-up license file poate fi restaurat doar pe același dispozitiv.

License Restore

Preparare:

  • A Windows PC has been set up with an IP address in the same subnet as the device. For exampDe exemplu, dacă adresa IP a dispozitivului (port Ethernet 1000M) este 192.168.0.100, setați adresa IP a PC-ului la 192.168.0.99.
  • A functioning Ethernet cable has been prepared.
  • The backed-up license file a fost obținută.

Pași

  1. Connect the device’s 1000M Ethernet port to the PC via an Ethernet cable, then power on the device.
  2. Enter http://192.168.0.100:8100 in the PC’s web browser pentru a accesa interfața „Setări PLC”.
  3. In the “Codesys License Management” interface, click “Restore License”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-57
  4. As prompted, select the obtained license file under a custom path.
  5. After a successful License Restore, a 100% progress bar will be displayed in the right-hand panel.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-58
  6. Open the device’s terminal command pane, execute the following command, and restart the device.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-59

Întrebări frecvente

Î: Pot reinstala sistemul de operare pe ED-PAC3020?

A: Reinstalling the operating system will invalidate the CODESYS license that comes pre-installed by default. It is advised not to attempt installing the OS on your own.

Î: Ce standarde de programare sunt acceptate de ED-PAC3020?

A: The device supports IEC 61131-3 programming standards and industrial communication protocols like EtherCAT and Modbus TCP.

Documente/Resurse

EDA ED-PAC3020 EDATEC Automatizare și control industrial [pdfManual de utilizare
ED-PAC3020 EDATEC Automatizări și control industrial, ED-PAC3020, EDATEC Automatizări și control industrial, Automatizări și control industrial, Automatizări și control

Referințe

Lasă un comentariu

Adresa ta de e-mail nu va fi publicată. Câmpurile obligatorii sunt marcate *