1. Introducere
This manual provides detailed instructions for the KAIWEETS HT206D Digital Clamp Meter and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light. These instruments are designed for accurate electrical measurements and automotive circuit testing, suitable for professional and household use. Please read this manual thoroughly before operation to ensure safe and correct usage.

Image 1.1: KAIWEETS HT206D Digital Clamp Meter and KAIWEETS 0.8V-100V DC Smart Automotive Test Light.
This image displays both the KAIWEETS HT206D Digital Clamp Meter (left) and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light (right). The clamp meter is red and black with a digital display and rotary dial. The test light is black with a digital display, probe, and alligator clip.
2. Informații de siguranță
Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, or personal injury. Keep this manual for future reference.
- Nu depășiți valorile maxime de intrare specificate pentru fiecare funcție.
- Fiți extrem de precauți când lucrați cu voltagpeste 30V AC RMS, 42V peak sau 60V DC. Aceste voltajetagreprezintă un pericol de șoc.
- Before measuring current, ensure the instrument is properly set up and the test leads are correctly connected.
- Deconectați întotdeauna sondele de testare de la circuit înainte de a schimba funcțiile sau intervalele.
- Inspect the test leads for damaged insulation or exposed metal before use. Replace if damaged.
- Do not operate the instrument if it appears damaged or if it is not functioning properly.
- Asigurați-vă că capacul bateriei este închis corect înainte de utilizare.
- Use caution when working in wet environments.
- For current measurement with the clamp meter, clamp around only one wire, not the entire power cord, to obtain an accurate reading.
3. Componentele produsului
3.1 KAIWEETS HT206D Digital Clamp Metru

Image 3.1: KAIWEETS HT206D Digital Clamp Contor și accesorii incluse.
This image shows the KAIWEETS HT206D Digital Clamp Meter along with its accessories: two 1.5V AA batteries, red and black test leads, a K-type thermocouple, and a carrying case.
KAIWEETS HT206D Digital Clamp Contorul include:
- Digital Clamp Unitate de contor
- Cabluri de testare (roșu și negru)
- Termocuplu de tip K
- Husă de transport
- Manual de utilizare (acest document)
- Batteries (typically 2x AA or AAA, check packaging for exact type)
3.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
The KAIWEETS 0.8V-100V DC Smart Automotive Test Light includes:
- Smart Automotive Test Light unit with coiled cable and alligator clip
- Manual de utilizare (acest document)
4. Configurare
4.1 KAIWEETS HT206D Digital Clamp Meter Battery Installation
- Localizați compartimentul bateriei pe spatele cl-ului.amp metru.
- Folosiți o șurubelniță pentru a deschide capacul bateriei.
- Insert the specified batteries (e.g., 2x AA 1.5V) according to the polarity markings inside the compartment.
- Puneți la loc capacul bateriei și fixați-l cu șurubul.
4.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
This device is typically powered by the circuit it is testing. No separate battery installation is required for the test light itself.
- Connect the alligator clip to a suitable ground point (e.g., vehicle chassis for automotive applications).
- Asigurați-vă că vârful sondei este curat și fără resturi.
5. Instrucțiuni de utilizare
5.1 KAIWEETS HT206D Digital Clamp Metru
Rotiți butonul rotativ pentru a selecta funcția de măsurare dorită.
5.1.1 Măsurarea curentului AC/DC (Clamp)
- Turn the rotary dial to the "600A" or "60A" AC/DC current range.
- Deschide clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws.
- Citiți valoarea curentă de pe afișaj.
- Important: To measure current, the clamp must enclose only one conductor. Clamping around an entire power cord (which contains both live and neutral wires) will result in a zero reading.

Image 5.1.1: KAIWEETS HT206D Digital Clamp Meter measuring current.
This image shows the KAIWEETS HT206D Digital Clamp Meter in use, clamping around a single electrical wire to measure current. The display shows a reading of "270.1 AC".
5.1.2 AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature Measurement
- Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack.
- Turn the rotary dial to the desired function (e.g., V~ for AC Voltage, V- pentru Vol DCtage, Ω for Resistance, etc.).
- For temperature measurement, connect the K-type thermocouple to the appropriate input jacks (usually marked with temperature symbols) and select the temperature function.
- Apply the test leads or thermocouple to the circuit or component under test.
- Citiți măsurarea pe afișaj.

Image 5.1.2: KAIWEETS HT206D Digital Clamp Meter performing temperature measurement.
This image illustrates the KAIWEETS HT206D Digital Clamp Meter measuring temperature using the included K-type thermocouple. Examples show measurements in liquid, gas, and solid states, with a temperature range of -4°F to 1832°F.
5.1.3 NCV (Volum fără contact)tage) Detectarea
- Press the NCV button (located on the right side of the meter).
- Mută partea de sus a cl-uluiamp contor în apropierea unui conductor sub tensiune.
- Contorul va indica prezența vol. ACtage through an audible beep and/or visual indicator.

Image 5.1.3: KAIWEETS HT206D Digital Clamp Meter NCV and HOLD functions.
This image demonstrates two functions of the clamp meter. On the left, the NCV (Non-Contact Voltage) function is shown detecting voltage near an outlet. On the right, the HOLD function is activated by a short press of the 'H' button, freezing the display reading.
5.1.4 LowZ & LPF Functions
- LowZ (Low Input Impedance): Helps prevent false readings caused by "ghost voltages" in circuits. Select this mode when ghost voltagsunt suspectați.
- LPF (filtru trece jos): Used for accurate measurement of variable frequency drive (VFD) signals, common in motor and transformer applications.
5.1.5 Data Hold (MAX/MIN)
- Press the "HOLD" button to freeze the current display reading. Press again to release.
- Press the "MAX/MIN" button to record the maximum or minimum values during a measurement session.
5.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
5.2.1 Smart Mode Operation
The test light defaults to Smart Mode, automatically detecting and measuring DC voltage, continuity, and resistance without manual range selection.
- Ensure the alligator clip is securely connected to a ground point.
- Touch the probe tip to the circuit or component to be tested.
- The display will automatically show the detected measurement type (DC Voltage, Continuity, or Resistance) and its value.

Image 5.2.1: KAIWEETS 0.8V-100V DC Smart Automotive Test Light in Smart Mode.
This image highlights the "Smart Mode" feature of the automotive test light, which automatically recognizes and measures DC Voltage, Resistance, and Continuity. The test light is shown in an automotive fuse box, demonstrating its application.
5.2.2 Wide Testing Range (0.8V-100V DC)
The test light can accurately measure DC voltages from 0.8V to 100V. If the voltage exceeds 100V, the display will show "OL" (Overload) as a warning.

Image 5.2.2: KAIWEETS 0.8V-100V DC Smart Automotive Test Light wide testing range.
This image demonstrates the test light's 0.8V-100V wide testing range, showing it connected to a car battery terminal. The display shows a voltage reading, and an inset illustrates the "OL" (Over-range warning) display for values exceeding 100V.
5.2.3 Lanternă și iluminare de fundal
- Press the flashlight button to activate the built-in flashlight for illuminating the work area.
- The green backlight display enhances readability in low-light conditions.

Image 5.2.3: KAIWEETS 0.8V-100V DC Smart Automotive Test Light with flashlight and backlight.
This image shows the automotive test light being used in a dark environment, highlighting its green backlight display and bright flashlight feature, which aids visibility during operation.
5.2.4 Buzzer Alarm for Continuity
When testing for continuity (typically less than 50Ω), the test light will emit an audible buzzer alarm to indicate a continuous circuit.

Image 5.2.4: KAIWEETS 0.8V-100V DC Smart Automotive Test Light buzzer alarm.
This image illustrates the buzzer alarm feature of the test light, which activates when testing for continuity (less than 50Ω). The test light is shown connected to a circuit, with visual cues indicating the sound waves from the buzzer.
6. Întreținere
- curatenie: Ștergeți instrumentul cu reclamăamp cârpă și detergent blând. Nu folosiți abrazivi sau solvenți.
- Battery Replacement (HT206D Clamp Meter): Când indicatorul de baterie descărcată apare pe afișaj, înlocuiți bateriile așa cum este descris în Secțiunea 4.1.
- Depozitare: Store the instruments in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove batteries from the clamp metru.
- Probe and Lead Inspection: Regularly inspect test leads and probes for any signs of damage, such as cuts, cracks, or exposed wiring. Replace damaged components immediately.
7. Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Clamp Contorul nu pornește. | Baterii descărcate sau instalate incorect. | Verificați polaritatea bateriilor; înlocuiți bateriile. |
| Clamp Meter shows "OL" (Overload). | Measurement exceeds selected range or instrument's maximum capacity. | Select a higher range if available, or ensure the measurement is within the instrument's specifications. |
| Clamp Meter current reading is zero. | Clamping around multiple conductors (e.g., a power cord). | Asigurați clamp jaws enclose only a single conductor. |
| Test Light shows "OL". | DC voltage depășește 100V. | Voltage is outside the test light's measurement range. Use a different instrument for higher voltages. |
| Citiri inexacte. | Poor contact, damaged leads, or incorrect function selection. | Ensure good contact, inspect and replace leads if damaged, verify correct function is selected. |
8. Specificații
8.1 KAIWEETS HT206D Digital Clamp Metru
- Functii de masurare: Curent AC/DC, Volum AC/DCtage, Resistance, Capacitance, Frequency/Duty Cycle, Diode, Continuity, Temperature
- Caracteristici speciale: True-RMS, LowZ, LPF, NCV Detection, Data Hold (MAX/MIN)
- Evaluare de siguranță: CAT III 600V (refer to device for exact rating)
- Sursa de alimentare: Battery Powered (e.g., 2x AA 1.5V)
8.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
- Functii de masurare: DC Voltage, Continuity, Resistance (Smart Mode auto-detection)
- Gama de testare: 0.8V - 100V CC
- Caracteristici speciale: Smart Mode, Flashlight, Green Backlight Display, Buzzer Alarm
- Min. Vol. operativtage: 0.8 volți (DC)
- Evaluare de siguranță: 300V CAT III (refer to device for exact rating)
9. Garanție și asistență
KAIWEETS products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official KAIWEETS website-ul web sau contactați direct serviciul lor de asistență pentru clienți. Păstrați bonul fiscal ca dovadă a achiziției.
KAIWEETS Official Website: www.kaiweets.com