1. Introducere
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your RunTru 60K BTU 80% AFUE 4 Ton Natural Gas Furnace, Model A801X. Please read this manual thoroughly before attempting any procedures. Retain this manual for future reference.
This furnace is designed to provide reliable heating for residential applications, featuring an 80% AFUE efficiency rating and a multi-speed blower for consistent comfort.
2. Informații de siguranță
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Consult a qualified installer, service agency, or the gas supplier before making any adjustments or modifications.
- Always turn off electrical power and gas supply to the unit before performing any service or maintenance.
- Ensure proper ventilation and combustion air supply as per local codes and manufacturer instructions.
- Do not store flammable materials, gasoline, or other combustible vapors and liquids near the furnace.
- Never operate the furnace without the access panels securely in place.
- Carbon Monoxide (CO) is a colorless, odorless, and poisonous gas. Install and maintain CO detectors in your home.
- Acest aparat trebuie instalat de către un profesionist calificat.
3. Produs terminatview
The RunTru A801X Series furnace is a high-efficiency heating system designed for versatile installation and reliable performance.

Figura 3.1: Față view of the RunTru 60K BTU Natural Gas Furnace, Model A801X.
Caracteristici cheie:
- Sistem de incalzire: Equipped with a versatile natural or propane gas option and a single-stage, multi-speed blower design for consistent, comfortable heating.
- Eficienţă: Converts 80% of its fuel into home heating, with 20% used in normal operation and vented out. Designed with durable metal flue venting.
- Flexibilitate de instalare: Offers multi-positional configurations (Upflow, Downflow, Horizontal) to suit various installation requirements.
4. Specificații
Detailed technical specifications for the RunTru A801X Series furnace.

Figure 4.1: Dimensions of the RunTru A801X Series Furnace. The unit measures 34.00 inches in height, 17.50 inches in width, and 28.75 inches in depth.

Figure 4.2: Detailed specifications including AHRI number, heating capacity, stage type, and electrical requirements.
| Atribut | Valoare |
|---|---|
| Marca | RunTru |
| Model | A801X |
| Dimensiuni produs (D x L x H) | 28.75 cm x 17.5 cm x 34 cm |
| Tip de montare | Montare pe podea |
| UPC | 721750058232 |
| Numărul AHRI | 204606302 |
| Capacitatea de incalzire | 60,000 BTU/h |
| Stage Tastați | singur Stage |
| CFM maxim | 1075 (4 tone) |
| Tip de aerisire | Metal Flue |
| Tip de suflantă | Multi-viteză |
| Ignitor Type | 120 V SiNi |
| Greutatea navei | 102 lbs (46.27 kg) |
| Electric | 120 V 1-Phase 60 Hz |
| Orientare | Multi-pozițional |
| Propane LP Kit | BAYLPSS400C (Unit is ready for Natural Gas) |
| Schimbător de căldură | 20 Gauge (Fired) Aluminized Steel |
| Efficiency Rating (AFUE) | 80.0% |

Figure 4.3: Energy Guide and AHRI Certificate of Product Ratings for the RunTru A801X Series Furnace, showing an 80.0% AFUE rating.
The efficiency of this furnace can vary depending on the type of air handler or blower installed by your contractor. High-quality components enhance heating performance and overall energy efficiency.
5. Instalare și configurare
IMPORTANT: Installation must be performed by a qualified HVAC technician in accordance with all local and national codes and manufacturer instructions.
5.1 Multi-Positional Installation
The RunTru A801X furnace is designed for flexible installation in Upflow, Downflow, or Horizontal configurations.

Figure 5.1: Diagram illustrating Upflow and Downflow vertical furnace orientations.
- Flux ascendent: The heat exchanger is positioned on top of the unit. Cool air is pulled from the side or bottom, heated, and released from the top. Commonly used in basements.
- Flux în jos: The heating coil or heat exchanger is located beneath the main furnace unit. Air enters from the top and exits from the bottom. Commonly used in closets or utility rooms.

Figure 5.2: Diagram illustrating Horizontal (Right/Left) furnace orientation.
Orizontală: When installing horizontally, ensure unobstructed airflow. This configuration is common in attic installations and allows for adaptability to airflow in either right or left directions. Proper duct placement and condensate drainage are crucial for efficiency.
5.2 Conexiunea la alimentarea cu gaz
The furnace is factory-configured for natural gas. If converting to propane (LP) gas, an LP conversion kit is required.

Figure 5.3: Components of an LP Conversion Kit. This kit allows the furnace to operate on propane gas.
NOTE: This furnace does NOT comply with California Low NOx or Ultra-Low NOx regulations.
5.3 Conexiune electrică
Connect the furnace to a dedicated 120 V, 1-Phase, 60 Hz electrical supply as per local electrical codes. Ensure proper grounding.
5.4 Conectarea la conducte
Connect the supply and return air ducts to the furnace. Ensure all connections are sealed to prevent air leaks and optimize system efficiency.
6. Instrucțiuni de utilizare
Once installed by a qualified technician, operating your RunTru furnace is straightforward.
6.1 Pornirea inițială
- Ensure all access panels are securely in place.
- Open the gas supply valve to the furnace.
- Porniți alimentarea cu energie electrică a cuptorului.
- Setați termostatul pe modul „Încălzire” și ajustați temperatura peste temperatura curentă a camerei.
- The furnace will initiate its startup sequence, which typically includes a pre-purge cycle, ignitor activation, and main burner ignition.
- Observe the furnace for proper operation during the first heating cycle. If any unusual noises or odors are detected, turn off the furnace and contact a qualified technician.
6.2 Funcționare normală
The furnace will cycle on and off as needed to maintain the temperature set on your thermostat. The multi-speed blower will distribute heated air throughout your home.
For optimal performance, keep your thermostat set to a comfortable temperature and avoid frequent, drastic temperature changes.
7. Întreținere
Regular maintenance ensures the longevity and efficient operation of your furnace. Always turn off power and gas before performing maintenance.
7.1 Înlocuirea filtrului de aer
Inspect and replace the air filter monthly, or more frequently if you have pets or allergies. A dirty filter restricts airflow, reduces efficiency, and can damage the furnace.
- Locate the filter slot, typically near the return air duct.
- Remove the old filter and note its size and airflow direction.
- Insert a new, clean filter, ensuring the airflow arrow points towards the furnace.
7.2 Inspecția profesională anuală
It is highly recommended to have a qualified HVAC technician inspect and service your furnace annually, preferably before the heating season begins. This includes:
- Checking and cleaning the burners.
- Inspecting the heat exchanger for cracks or damage.
- Verificarea presiunii corecte a gazului și a arderii.
- Lubrifierea pieselor mobile (dacă este cazul).
- Testing safety controls and electrical connections.
- Cleaning the blower assembly.
8. Depanare
Înainte de a apela la service, review the following common issues and solutions. Always turn off power and gas before inspecting the unit.
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Fără căldură | Termostatul setat incorect | Set thermostat to "Heat" and desired temperature. |
| Opriți alimentarea | Ensure furnace power switch is on. Check circuit breaker. | |
| Alimentarea cu gaz oprită | Ensure gas valve to furnace is open. | |
| Filtru de aer murdar | Înlocuiți sau curățați filtrul de aer. | |
| Flux de aer slab | Filtru de aer murdar | Înlocuiți sau curățați filtrul de aer. |
| Blocked return/supply vents | Ensure all vents are open and unobstructed. | |
| Zgomote neobișnuite | Loose panel or component | Inspect for loose parts. Tighten if safe to do so. |
| Blower motor issue | Contactați un tehnician calificat. |
If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.
9. Informații despre garanție
The RunTru A801X Series furnace comes with the following warranty conditions:
- Schimbător de căldură: 20 ani
- Piese: 10 ani
These warranty durations are applicable when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please refer to the official RunTru warranty documentation for complete terms and conditions.
10. Asistență pentru clienți
For technical assistance, service inquiries, or to locate a qualified RunTru service provider, please refer to the contact information provided with your product packaging or visit the official RunTru website-ul.