This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ACiQ 1.5 Ton 16 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before attempting any procedures. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

Imaginea 1.1: Pesteview of the ACiQ 1.5 Ton Central Air Conditioner System and included installation kit.
2. Informații de siguranță
WARNING: Installation and servicing of this equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only qualified, trained, and licensed HVAC technicians should install, repair, or service this equipment. Failure to follow this warning could result in property damage, personal injury, or death.
- Deconectați întotdeauna alimentarea unității înainte de a efectua orice operațiune de întreținere sau service.
- Purtați echipament individual de protecție (EIP) adecvat, inclusiv mănuși și ochelari de protecție.
- Asigurați o împământare corespunzătoare a tuturor componentelor electrice.
- Nu utilizați unitatea cu cabluri sau componente electrice deteriorate.
- Țineți copiii și animalele de companie departe de unitate în timpul funcționării și întreținerii.
3. Conținutul pachetului
Verificați dacă toate componentele enumerate mai jos sunt prezente în pachet:
- Unitate de condensare exterioară
- Indoor Evaporator Cased Coil (Multi-Positional)
- Termostat WiFi inteligent
- 30' Insulated Line Set (3/8" LL x 3/4" SL x 3/8")
- 1/2" x 6' 10 Gauge Electrical Whip
- 60A Non-fused Disconnect Switch
- Controls Surge Protector
- CPS Charging Adapter
- Manșon de perete
- Suport de montare pe perete
- Manual de utilizare (acest document)

Image 3.1: Components included in the ACiQ Split System Installation Kit.
4. Produs terminatview și Caracteristici
4.1. Inverter AC Technology
The ACiQ system utilizes inverter technology, which allows the compressor to adjust its speed continuously. This precise control maintains a consistent indoor temperature, reduces energy consumption, and results in quieter operation compared to traditional single-stagsisteme e.
4.2. Multi-Positional Evaporator Cased Coil
The included cased coil is designed for multi-positional installation, offering flexibility for various HVAC system configurations. It features a factory-integrated TXV (Thermostatic Expansion Valve) for optimized refrigerant flow and enhanced system efficiency.
4.3. Smart Thermostat
The system comes with a Smart WiFi Thermostat, enabling remote control and advanced scheduling features. It integrates with popular smart home platforms for convenient management of your home's climate.

Image 4.1: Key features of the ACiQ Air Conditioner, including inverter technology, gold fin coil, and quiet operation.

Image 4.2: Detailed features and interface of the included Smart Thermostat.
5. Specificații
| Caietul de sarcini | Valoare |
|---|---|
| Nume de marcă | ACiQ |
| Informații despre model | ACiQ-18-AC / ACIQ-24-ACL / IKIC31 |
| Capacitate | 1.5 tone (18000 BTU/h) |
| Evaluare SEER2 | Până la 16.8 |
| Voltage | 230 volți |
| Wattage | 1538 wați |
| Tip de instalare | Sistem Split |
| Factor de formă | Central Split System |
| Caracteristici speciale | Inverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance |
| Acoperirea suprafeței podelei | Până la 900 de metri pătrați |
| Dimensiuni condensator exterior (A x L x Î) | 13.46 x 35.04 x 26.5 inci |
| Evaporator Coil Dimensions (W x D x H) | 17.52 x 20.98 x 17.99 inci |
| Evaporator Coil Air Flow | 720.04 CFM |
| Evaporator Coil Dehumidification | 3.02 |

Image 5.1: Dimensional measurements for the ACiQ outdoor condenser and evaporator coil.

Image 5.2: Detailed specifications for the ACiQ evaporator coil.
6. Configurare și instalare
IMPORTANT: This ACiQ Central Air Conditioner System requires professional installation by a qualified and licensed HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, voided warranty, and improper operation.
6.1. Verificări înainte de instalare
- Ensure the installation site meets local building codes and regulations.
- Verify that the electrical supply matches the unit's requirements (230 Volts).
- Confirm adequate space for both the outdoor condenser and indoor evaporator coil, allowing for proper airflow and service access.
6.2. Pași de instalare (peste)view pentru Tehnician)
- Mounting the Outdoor Condenser: Securely mount the outdoor unit using the provided wall mount bracket or a suitable ground-level pad, ensuring proper drainage and vibration isolation.
- Installing the Indoor Evaporator Coil: Integrate the multi-positional cased coil with your existing furnace or air handler, ensuring proper sealing and airflow.
- Conectarea conductelor de agent frigorific: Connect the insulated line set between the outdoor and indoor units. This involves brazing and vacuuming the lines to remove moisture and non-condensable gases, followed by charging with R410A refrigerant.
- Cablaj electric: Connect the electrical whip, disconnect switch, and controls surge protector according to wiring diagrams provided with the unit and local electrical codes. Connect the smart thermostat.
- Pornirea și testarea sistemului: Perform a leak check, verify proper refrigerant charge, test all operational modes, and calibrate the thermostat.
7. Instrucțiuni de utilizare
Once professionally installed, your ACiQ system is designed for user-friendly operation primarily through the Smart WiFi Thermostat.
7.1. Smart Thermostat Operation
Refer to the separate Smart WiFi Thermostat manual for detailed instructions on its features, including:
- Setting desired temperature (cooling/heating set points).
- Selecting operating modes (Cool, Heat, Auto, Fan Only).
- Programming schedules and presets.
- Connecting to your home's WiFi network for remote access via a mobile application.
- Integration with voice assistants (e.g., Alexa, Google Assistant) and smart home platforms (e.g., SmartThings, IFTTT).
7.2. Inverter Technology Benefits
The inverter system automatically adjusts its output to match the cooling demand, providing consistent comfort and energy savings. You may notice the compressor running at varying speeds, which is normal operation for an inverter unit.
8. Întreținere
Regular maintenance ensures the efficiency and longevity of your ACiQ system. Some tasks can be performed by the homeowner, while others require a professional technician.
8.1. Întreținere utilizator
- Clean or Replace Air Filters: Check your furnace/air handler's air filter monthly and clean or replace it as needed. A dirty filter restricts airflow and reduces efficiency. The system uses a washable, reusable mesh filter.
- Unitate exterioară curată: Mențineți zona din jurul unității condensatorului exterioare liberă de resturi, frunze și vegetație pentru a asigura un flux de aer adecvat.
- Clean Evaporator Coil Drain Pan: Periodically check and clean the condensate drain pan to prevent clogs and water overflow.
8.2. Întreținere profesională
Schedule annual maintenance with a qualified HVAC technician. This typically includes:
- Verificarea nivelurilor și presiunii agentului frigorific.
- Cleaning condenser and evaporator coils.
- Inspectarea conexiunilor și componentelor electrice.
- Lubrifierea pieselor mobile (dacă este cazul).
- Checking thermostat calibration.
- Inspecting ductwork for leaks.
9. Depanare
Înainte de a apela la service, review aceste probleme și soluții comune:
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Sistemul nu răcește/încălzește | Thermostat setting incorrect, dirty air filter, power supply issue, tripped breaker. | Check thermostat settings, replace/clean filter, check circuit breaker, ensure power is on. |
| Flux de aer slab | Dirty air filter, blocked vents, obstructed outdoor unit. | Clean/replace filter, ensure vents are open, clear debris from outdoor unit. |
| Zgomote neobișnuite | Loose parts, debris in fan, refrigerant issues. | Inspect for loose panels or debris. If persistent, contact a technician. |
| Scurgeri de apă | Clogged condensate drain line, frozen evaporator coil. | Clear drain line. If coil is frozen, turn off unit and contact a technician. |
If these steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.
10. Garanție și asistență
10.1. Condiții de garanție
Your ACiQ Central Air Conditioner System comes with a warranty of 7 ani la piese şi 12 ani la compresor. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please retain your proof of purchase and installation records.
10.2. Asistență pentru clienți
For technical assistance, warranty claims, or to locate a certified service provider, please visit the official ACiQ website or contact their customer support line. (Specific contact details are typically provided on the manufacturer's website or warranty card.)
11. AHRI Rating Conditions
AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification is essential for HVAC units as it assures performance, energy efficiency, quality, regulatory compliance, and provides benefits like market differentiation, financial incentives, and consumer protection.

Image 11.1: AHRI Certification and EnergyGuide label details for the ACiQ system, showing SEER2 rating and cooling capacity.
The manufacturer of this ACiQ product is responsible for the rating of this system combination. The unit is rated as follows in accordance with the latest edition of AHRI 210/240-2024, Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment:
- AHRI Certified Number: 214731227
- Data: 08-26-2024
- Model Status: Activ
- AHRI Type: RCU-A-C (Split System: Air-Cooled Condensing Unit, Coil Alone)
- Nume de marcă: ACiQ
- Unitate exterioară: ACiQ-18-AC
- Unitate interioară: ACiQ-24-ACL
- Cooling Capacity BTU/h: 18000
- SEER2: 16.00
- EER2 Single or High Stage: 11.70