Introducere
This manual provides comprehensive instructions for the safe and efficient operation, maintenance, and troubleshooting of your Pulsar GD240N portable inverter generator. Please read this manual thoroughly before operating the generator to ensure proper usage and longevity of the product.
Caracteristici cheie:
- 2400W starting watts, 1800W running watts
- Type A & Type C USB ports
- Funcționare super silențioasă
- Three-in-one switch for simplified control
- Parallel capability to combine with another unit for increased power output
- Enhanced fuel efficiency
Informații de siguranță
PERICOL: Pericol de monoxid de carbon
Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH. Operate in well-ventilated, outdoor areas away from open windows or doors. Point exhaust away from occupied areas. Do not run generator in enclosed areas (e.g., not in house or garage). Move to fresh air and get medical help if sick, dizzy, or weak.
Always ensure the generator is placed on a level surface and away from any flammable materials. Keep children and pets away from the operating unit.
Conținutul pachetului
Your Pulsar GD240N generator package includes the following items:
- Pulsar GD240N Portable Inverter Generator
- Manual de utilizare
- Pâlnie de petrol
- Basic Tool Kit (screwdriver)
Înființat
Adăugarea uleiului de motor
Before starting the generator for the first time, you must add engine oil. The generator is shipped without oil.
- Locate the oil fill cap on the side of the generator.
- Remove the side panel by unscrewing the two screws.
- Scoateți capacul de umplere/joja de ulei.
- Using the provided funnel, carefully add 5W-30 engine oil until it reaches the upper mark on the dipstick. The oil capacity is approximately 0.33 - 0.35 US Quarts (11.2 oz).
- Replace the oil fill cap and secure the side panel.

Image: Locating the oil fill cap and adding 5W-30 engine oil to the Pulsar GD240N inverter generator.
Adăugarea de combustibil
Use only fresh, unleaded gasoline with an octane rating of 87 or higher. Do not use E85 fuel.
- Asigurați-vă că generatorul este pe o suprafață plană și că motorul este oprit și răcit.
- Deșurubați capacul combustibilului.
- Carefully fill the fuel tank (capacity 1.18 Gallons) with gasoline, leaving a small air gap at the top to allow for fuel expansion.
- Puneți la loc capacul rezervorului de combustibil în siguranță.
Comenzi terminateview
Familiarize yourself with the control panel located on the front of the generator:
- Comutator motor: A three-in-one switch for OFF, RUN, and CHOKE positions.
- Comutator mod Eco: Activates or deactivates Eco mode for improved fuel efficiency and quieter operation under light loads.
- AC 120V 20A Outlets: Two standard household outlets.
- AC 120V 30A Outlet: For higher power demands (e.g., RVs).
- Porturi USB: Includes Type A and Type C ports for charging electronic devices.
- DC 12V Outlet: For 12-volt DC appliances.
- Întrerupător/Buton de resetare: Resets the circuit in case of an overload.
- Parallel Connection Ports: Allows connection of two compatible generators for increased power.
- Indicatoare luminoase: Displays status for Low Oil, Overload, and Output.

Imagine: Detaliată view of the Pulsar GD240N control panel, showing AC outlets, USB ports, DC 12V outlet, and various switches and indicator lights.
Instrucțiuni de operare
Pornirea generatorului
- Asigurați-vă că generatorul are suficient ulei și combustibil.
- Rotiți robinetul de combustibil în poziția „ON”.
- Move the engine switch to the 'CHOKE' position (if the engine is cold).
- Trageți ferm de mânerul demarorului cu recul până când motorul pornește.
- Once the engine starts, gradually move the engine switch to the 'RUN' position.
- Lăsați generatorul să se încălzească câteva minute înainte de a conecta sarcinile electrice.

Image: The side of the Pulsar GD240N generator showing the engine switch in the 'RUN' position.
Mod Eco
The Eco Mode switch allows the generator to adjust engine speed based on the load, optimizing fuel consumption and reducing noise levels. For light loads, switch to 'ON' for quieter and more efficient operation. For heavy loads or when starting high-demand appliances, switch to 'OFF' to ensure full power is available.
Conectarea dispozitivelor
Connect your electrical devices to the appropriate outlets on the control panel. Ensure that the total wattagputerea dispozitivelor conectate nu depășește puterea de funcționare a generatoruluitage (1800W) to prevent overloading.
Operațiune paralelă
The Pulsar GD240N is equipped with parallel connection ports, allowing you to link two compatible Pulsar inverter generators together to double your power output. Refer to the parallel kit's instruction manual for detailed connection procedures.
Întreţinere
Regular maintenance is crucial for the optimal performance and longevity of your generator. Always ensure the engine is off and cool before performing any maintenance.
Schimbarea uleiului de motor
Change the engine oil after the first 20 hours of use or the first month, whichever comes first. Subsequent oil changes should be performed every 100 hours or every 6 months.
- Așezați un recipient adecvat sub dopul de golire a uleiului.
- Scoateți dopul de golire a uleiului și capacul de umplere cu ulei pentru a permite uleiului să se scurgă complet.
- Once drained, replace the oil drain plug.
- Refill with fresh 5W-30 engine oil as described in the 'Adding Engine Oil' section.
Spark Plug Access
The spark plug is accessible for inspection and replacement. Remove the spark plug cover to access the spark plug. Inspect the spark plug for wear and proper gap. Replace if necessary.
Distactor de scântei
The generator is equipped with a spark arrestor, making it US Forestry approved. Regularly inspect and clean the spark arrestor to prevent carbon buildup, which can restrict exhaust flow and affect performance. Refer to the owner's manual for detailed cleaning instructions.

Imagine: Spate view of the Pulsar GD240N generator, highlighting the exhaust port and spark arrestor.
Depanare
If your generator experiences issues, consult the following common troubleshooting tips:
Indicatoare luminoase
- Lumină ulei scăzut: If illuminated, check and add engine oil. The generator may shut down automatically to prevent engine damage.
- Lumină de suprasarcină: If illuminated, the generator is overloaded. Disconnect some devices and press the reset button.
- Lumina de ieșire: A green light indicates normal power output.
Probleme comune
- Motorul nu pornește: Check fuel level, oil level, spark plug, and ensure the engine switch is in the correct position.
- Fără putere de ieșire: Check for tripped circuit breakers, ensure the generator is not overloaded, and verify all connections.
Specificații
| Marca | Pulsar |
| Numele modelului | Pulsar 2,400W Portable Gas-Powered Quiet Inverter Generator With USB Outlet & Parallel Capability, GD240N |
| Numărul piesei | GD240N |
| Începând Wattage | 2400 wați |
| Alergând Wattage | 1800 wați |
| Tip de combustibil | Benzină |
| Sursa de alimentare | Alimentat cu combustibil |
| Voltage | 120 volți |
| Tip motor | 4 AVC |
| Volumul rezervorului | 1.18 de galoane |
| Greutatea articolului | 30.8 lire sterline |
| Dimensiunile produsului | 17.3 cm L x 9.7 cm l x 15.9 cm Î |
| Prize de putere totală | 2 (AC 120V 20A) + 1 (AC 120V 30A) + USB Type A + USB Type C + DC 12V |
| Caracteristici speciale | Extra-Long Run Time, Fuel Efficient, Lightweight, Low Oil Shutdown, Portable |
Garanție și suport
Informații despre garanție
This Pulsar GD240N inverter generator comes with a 2-Year Manufacturer's Warranty. Please retain your proof of purchase for warranty claims.
Asistență pentru clienți
For technical assistance, warranty inquiries, or to order replacement parts, please contact Pulsar Products customer support. Refer to the official Pulsar website-ul sau documentația achiziției pentru datele de contact.