1. Introducere
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Senville AURA Series Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage.
The Senville AURA Series is designed to provide efficient cooling and heating for various spaces, including individual rooms, additions, garages, and commercial applications. It features DC Inverter Technology for high efficiency and quiet operation.

Figure 1.1: Complete Senville AURA Series Mini Split System Components.
2. Informații de siguranță
Always adhere to the following safety precautions to reduce the risk of fire, electric shock, injury, or property damage.
- Instalarea trebuie efectuată de către personal calificat, în conformitate cu toate codurile locale și naționale aplicabile.
- Asigurați-vă că sursa de alimentare corespunde specificațiilor unității (208-230 V).
- Nu introduceți degetele sau obiecte în orificiul de admisie/evacuare a aerului.
- Nu încercați să reparați unitatea singur. Contactați personal de service calificat.
- Turn off the power supply before cleaning or performing maintenance.
3. Componentele produsului
The Senville AURA Series SENA-48HF/F system includes the following main components:
- (5) 9000 BTU Indoor Air Handlers
- (1) 48000 BTU Outdoor Condenser
- Wireless Remote Controls (one for each indoor unit)
- Pre-charged refrigerant lines (up to 125 ft)
- Installation accessories (drain hoses, electrical wiring, insulation tape)

Figure 3.1: Indoor Air Handler Unit.

Figura 3.2: Telecomandă fără fir.

Figure 3.3: Included Installation Accessories.
4. Instalare și configurare
Installation of the Senville AURA Series mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician.
4.1 Lista de verificare înainte de instalare
- Verificați că toate componentele sunt prezente și nedeteriorate.
- Ensure adequate space for indoor and outdoor units, allowing for proper airflow and maintenance access.
- Confirm electrical supply meets 208-230V requirements and dedicated circuit is available.
4.2 Pași de instalare (pesteview pentru Tehnician)
- Mount indoor air handlers in desired locations, ensuring proper drainage.
- Position the outdoor condenser unit on a stable, level surface, away from obstructions.
- Connect refrigerant lines between indoor and outdoor units. The system is pre-charged for up to 125 feet of line.
- Connect electrical wiring according to the wiring diagram provided in the full installation manual.
- Efectuați aspirarea conductelor de agent frigorific pentru a îndepărta aerul și umezeala.
- Verificați dacă există scurgeri folosind metode adecvate.
- Open service valves to release refrigerant.
- Test the system for proper operation in both cooling and heating modes.
5. Instrucțiuni de utilizare
Your Senville AURA Series system is designed for user-friendly operation via the wireless remote control.
5.1 Funcții de control de la distanță
Refer to Figure 3.2 for a visual guide to the remote control buttons.
- Buton de alimentare: Pornește / oprește unitatea.
- Butonul de mod: Comută între modurile de funcționare: Auto, Răcire, Uscare, Încălzire, Ventilator.
- Reglarea temperaturii: Folosiți săgețile SUS/JOS pentru a seta temperatura dorită.
- Viteza ventilatorului: Reglează viteza ventilatorului (Auto, Mică, Medie, Mare).
- Leagăn: Controlează oscilația jaluzelelor pentru distribuția aerului.
- ECO Gear: Activează modul de economisire a energiei.
- Cronometru: Setează temporizatoarele PORNIT/OPRIT pentru funcționarea programată.
5.2 Moduri de operare
- Mod cool: Provides cooling. Ideal for summer months.
- Mod încălzire: Provides heating. Effective down to -22°F (-30°C) with Arctic Heat Pump technology.
- Mod uscat: Dezumidifică aerul.
- Mod ventilator: Circulă aerul fără încălzire sau răcire.
- Mod auto: Selectează automat răcirea sau încălzirea în funcție de temperatura ambiantă.

Figure 5.1: Operating Temperature Range.
5.3 Funcții inteligente
- Whisper Technology: Ensures quiet operation, with noise levels as low as 23.5 dB.
- Smart Saving: Built-in intelligent eye detects human movement to automatically adjust operation and save energy.
- Comenzi inteligente: Compatible with voice control (e.g., Alexa) and app control (requires Alexa Kit installation).

Figure 5.2: Low Noise Operation.

Figure 5.3: Smart Saving Feature.

Figure 5.4: Smart Controls with Alexa Integration.
6. Întreținere
Regular maintenance ensures optimal performance and longevity of your Senville AURA system.
6.1 Curăţarea filtrului
- Clean air filters every two weeks or more frequently depending on usage and air quality.
- Open the front panel of the indoor unit, remove filters, and wash with lukewarm water.
- Lăsați filtrele să se usuce complet înainte de a le introduce la loc.
6.2 Întreținerea unității exterioare
- Keep the area around the outdoor unit clear of debris, leaves, and snow.
- Periodically clean the outdoor coil with a soft brush or vacuum cleaner.
- Ensure proper drainage from the outdoor unit.
6.3 Servicii profesionale
It is recommended to have a certified HVAC technician perform annual inspections and maintenance, including checking refrigerant levels, electrical connections, and overall system performance.
7. Depanare
Înainte de a contacta serviciul de asistență pentru clienți, vă rugăm să consultați următoarele probleme și soluții frecvente:
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Unitatea nu pornește. | Fără curent, bateriile telecomenzii sunt descărcate, întrerupătorul de circuit s-a declanșat. | Verificați alimentarea cu energie electrică, înlocuiți bateriile telecomenzii, resetați întrerupătorul de circuit. |
| Răcire/încălzire insuficientă. | Dirty air filters, blocked outdoor unit, incorrect mode setting, low refrigerant. | Curățați filtrele, îndepărtați obstrucțiile, selectați modul corect, contactați un tehnician pentru verificarea agentului frigorific. |
| Zgomot neobișnuit. | Piese slăbite, obstrucționarea ventilatorului, sunete normale de funcționare (de exemplu, debitul agentului frigorific). | Inspect for loose parts, remove obstructions. If persistent or loud, contact technician. |
| Scurgeri de apă din unitatea interioară. | Furtun de scurgere înfundat, instalare necorespunzătoare. | Check and clear drain hose. If issue persists, contact technician. |
8. Specificatii tehnice
| Caracteristică | Caietul de sarcini |
|---|---|
| Numărul de model | SENA-48HF/F |
| Capacitate | 48000 BTU (4 tone) |
| Unități interioare | (5) 9000 BTU Air Handlers |
| Unitate exterioară | (1) 48000 BTU Condenser |
| Voltage | 208-230 volți |
| Eficiență (SEER) | 22.0 |
| Nivel de zgomot (interior) | 23.5 dB (Whisper Technology) |
| Dimensiunile produsului | 48"D x 48"W x 60"H (Overall System) |
| Caracteristici speciale | Heating and Cooling Function, DC Inverter Technology, Smart Saving, Smart Controls (Alexa compatible) |
| Certificari | ETL Intertek Approved, AHRI Certified, ENERGYSTAR |
9. Informații despre garanție
The Senville AURA Series is backed by a comprehensive warranty:
- Piese de garantie: 5 ani
- Garantie compresor: 10 ani
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Senville website-ul.
10. Asistență pentru clienți
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Senville customer support.
- Website: Visit the Senville Store on Amazon
- Întrebări generale: Refer to the contact information provided in your product packaging or on the official Senville website-ul.

Figure 10.1: Senville Customer Support.