1. Introducere
The Sonel CMM 30 is an advanced industrial multimeter engineered for versatility, modern functionality, and exceptional durability. This device integrates 11 fundamental measurement functions along with additional features, providing a broad spectrum of applications for professionals. Its robust design includes drop protection and an IP67 rated casing, ensuring reliable performance even in challenging environments.
Key features include a smartphone application for remote reading and data saving via wireless communication, an automatically adjusting backlight for optimal screen visibility, and a built-in flashlight for illumination in dark conditions. This manual provides essential information for the safe and effective use of your CMM 30 multimeter.
2. Informații de siguranță
Always adhere to the following safety precautions to prevent electric shock, injury, or damage to the meter or equipment under test.
- Read and understand all instructions and safety information in this manual before operating the meter.
- Nu utilizați aparatul de măsură dacă pare deteriorat sau dacă izolația cablurilor de testare este compromisă.
- Deconectați întotdeauna alimentarea circuitului și descărcați toate curentul de mare tensiune.tage capacitors before making resistance, continuity, diode, or capacitance measurements.
- Aveți grijă când lucrați cu voltagpeste 30V AC RMS, 42V peak sau 60V DC. Aceste voltajetagreprezintă un pericol de șoc.
- Nu depășiți limitele maxime de intrare pentru nicio funcție.
- Asigurați-vă că comutatorul de funcții este în poziția corectă pentru măsurarea dorită înainte de a conecta sondele de testare la circuit.
- Înlocuiți bateriile imediat ce apare indicatorul de baterie descărcată pentru a asigura citiri precise.
- Nu utilizați contorul în medii cu gaze, vapori sau praf exploziv.
3. Conținutul pachetului
Verify that all items listed below are present and undamaged upon opening the package:
- Sonel CMM 30 Industrial Multimeter
- Cabluri de testare (roșu și negru)
- Temperature Probe (K-type thermocouple)
- 4 x AAA Batteries (pre-installed or separate)
- Manual de utilizare (acest document)
Dacă lipsesc sau sunt deteriorate articolele, vă rugăm să contactați imediat furnizorul.
4. Produs terminatview
Familiarize yourself with the components of your Sonel CMM 30 multimeter:

Figura 4.1: Față view of the Sonel CMM 30 Industrial Multimeter. This image displays the device's main components, including the digital display, the central rotary function switch, and the various input terminals for test leads.
4.1. Afișare
The large LCD shows measurement readings, units, function indicators, and battery status. It features an automatic backlight that adjusts to ambient light conditions for optimal visibility.
4.2. Comutator de funcție rotativ
This central switch is used to select the desired measurement function (e.g., Voltage, Current, Resistance, Capacitance, Temperature, Frequency).
4.3. Butoane funcționale
Various buttons provide additional controls and features:
- GAMĂ: Toggles between manual and automatic ranging.
- Mod de administrare: Selects sub-functions within a main rotary switch position (e.g., AC/DC voltage., Diodă/Continuitate).
- ȚINEȚI: Îngheață citirea curentă a afișajului.
- MAX/MIN/MEDIE: Records maximum, minimum, and average readings.
- REL: Relative mode, subtracts a stored value from subsequent measurements.
- Bluetooth/Light: Activates Bluetooth connectivity for the smartphone app and controls the built-in flashlight.
4.4. Input Jacks
These are the connection points for the test leads:
- COM: Common terminal for the black test lead.
- VΩHzCAP°C: Intrare pentru voltage, resistance, frequency, capacitance, and temperature measurements (red test lead).
- mAµA: Intrare pentru miliampere și microampere current measurements (red test lead).
- 10A: Input for up to 10 Ampere current measurements (red test lead).
5. Configurare
5.1. Instalarea bateriei
The Sonel CMM 30 requires 4 AAA batteries. These may be pre-installed or included separately.
- Asigurați-vă că multimetrul este oprit.
- Locate the battery compartment on the rear of the meter.
- Folosiți o șurubelniță pentru a slăbi șurubul (șuruburile) care fixează capacul bateriei.
- Scoateți capacul bateriei.
- Insert the 4 AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery cover and tighten the screw(s) securely.
Nota: Always use fresh batteries of the same type. Remove batteries if the meter is not used for an extended period to prevent leakage.
6. Instrucțiuni de utilizare
6.1. Pornire/Oprire
Turn the rotary function switch from the OFF position to any desired measurement function to power on the meter. To power off, turn the switch back to the OFF position.
6.2. Basic Measurement Procedures
Before any measurement, ensure the test leads are correctly inserted into the appropriate input jacks for the selected function.
6.2.1. ZbortagMăsurare (AC/DC)
- Insert the black test lead into the COM jack and the red test lead into the VΩHzCAP°C jack.
- Rotiți comutatorul rotativ la poziția V~ (Volum ACtage) sau V- (Volum CCtage) position. If both are combined, use the MODE button to select AC or DC.
- Conectați sondele de testare în paralel pe circuitul sau componenta care urmează a fi măsurată.
- Citiți voltage valoarea pe display.
6.2.2. Măsurarea curentului (AC/DC)
Atenţie: Never connect the meter in parallel for current measurement. Always connect in series with the circuit.
- Insert the black test lead into the COM jack. For currents up to 10A, insert the red test lead into the 10A jack. For smaller currents (mA/µA), insert the red test lead into the mAµA jack.
- Turn the rotary switch to the A~ (AC Current) or A- (DC Current) position, or the mA/µA position as appropriate. Use the MODE button to select AC or DC if needed.
- Deschideți circuitul unde urmează să se măsoare curentul și conectați aparatul de măsură în serie.
- Citiți valoarea curentă de pe afișaj.
6.2.3. Măsurarea rezistenței
- Insert the black test lead into the COM jack and the red test lead into the VΩHzCAP°C jack.
- Rotiți comutatorul rotativ în poziția Ω (rezistență).
- Ensure the circuit or component is de-energized before connecting the test leads across it.
- Citiți valoarea rezistenței pe afișaj.
6.2.4. Măsurarea capacității
- Insert the black test lead into the COM jack and the red test lead into the VΩHzCAP°C jack.
- Turn the rotary switch to the CAP (Capacitance) position.
- Ensure the capacitor is fully discharged before connecting the test leads across it.
- Citiți valoarea capacității pe afișaj.
6.2.5. Măsurarea temperaturii
- Insert the temperature probe into the VΩHzCAP°C and COM jacks, observing polarity if applicable.
- Turn the rotary switch to the °C/°F (Temperature) position.
- Așezați vârful sondei de temperatură pe sau lângă obiectul a cărui temperatură trebuie măsurată.
- Citiți valoarea temperaturii de pe afișaj.
6.3. Caracteristici avansate
6.3.1. True RMS Measurement
The CMM 30 features True RMS for AC voltage and current measurements, providing accurate readings for non-sinusoidal waveforms.
6.3.2. Wireless Communication and Smartphone App
The CMM 30 can connect wirelessly to a smartphone application, allowing for remote reading and saving of measurements. This is particularly useful in hard-to-reach or hazardous locations.

Figure 6.1: The Sonel CMM 30 Multimeter connected to an electrical panel, demonstrating its wireless communication feature. A smartphone displays the measurement reading remotely, highlighting the convenience for inaccessible areas.
Pentru a utiliza această caracteristică:
- Download the official Sonel CMM app from your smartphone's app store.
- Activați Bluetooth pe smartphone-ul dvs.
- Press the Bluetooth button on the multimeter to activate its wireless communication.
- Follow the app's instructions to pair with your CMM 30 and begin remote monitoring.
6.3.3. Lanterna incorporata
The integrated flashlight assists in illuminating measurement areas, especially in low-light conditions. Activate it by pressing the dedicated light button.
6.4. Durability and IP67 Rating
The CMM 30 is designed with an IP67 rating, signifying its protection against dust ingress and immersion in water up to 1 meter for 30 minutes. This makes it suitable for demanding industrial environments.

Figure 6.2: The Sonel CMM 30 Multimeter partially submerged in gravel, illustrating its robust construction and resistance to dust and debris, a testament to its IP67 rating.

Figure 6.3: The Sonel CMM 30 Multimeter creating a splash as it impacts a muddy puddle, demonstrating its exceptional water resistance and ability to withstand harsh, wet conditions.

Figure 6.4: A person, wearing protective boots and gloves, retrieves the Sonel CMM 30 Multimeter from a muddy environment. This image emphasizes the device's resilience and ease of handling even after exposure to challenging conditions.
7. Întreținere
7.1. Curatenie
Ștergeți suprafața contoruluiasing cu anunțamp o lavetă și un detergent blând. Nu utilizați abrazive sau solvenți. Asigurați-vă că aparatul de măsură este complet uscat înainte de utilizare.
7.2. Înlocuirea bateriei
Consultați Secțiunea 5.1 pentru instrucțiuni de înlocuire a bateriilor. Înlocuiți bateriile imediat ce indicatorul de baterie descărcată apare pe afișaj.
7.3. Depozitare
When not in use for extended periods, store the multimeter in a dry, cool place, away from direct sunlight and extreme temperatures. Remove the batteries to prevent leakage.
8. Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Contorul nu pornește. | Baterii descărcate sau instalate incorect. | Verificați polaritatea bateriilor sau înlocuiți bateriile. |
| Nicio citire sau este afișat mesajul „OL” (supraîncărcare). | Incorrect function selected; open circuit; measurement exceeds range. | Select correct function; check circuit continuity; switch to a higher range or auto-range. |
| Citiri inexacte. | Low battery; dirty test leads/jacks; external interference. | Replace batteries; clean leads/jacks; move away from strong electromagnetic fields. |
| Probleme de conexiune Bluetooth. | Bluetooth not enabled on meter/phone; app issues; distance. | Ensure Bluetooth is on; restart app/phone; reduce distance between devices. |
9. Specificații
| Caracteristică | Caietul de sarcini |
|---|---|
| Marca | Sonel |
| Numărul de model | SON001 |
| Culoare | Negru |
| Greutatea articolului | 418 g |
| Dimensiuni pachet | 30 x 15 x 10 cm |
| baterii | Sunt necesare 4 baterii AAA (incluse) |
| Funcții de măsurare | AC / DC Voltage, AC/DC Current, Resistance, Capacity, Temperature, Duty Cycle, Frequency |
| Variind | Manual si Automat |
| RMS adevărat | Yes (for AC voltage și curent) |
| Evaluare de protecție la pătrundere (IP). | IP67 |
| Conectivitate | Wireless (Smartphone App) |
| Caracteristici suplimentare | HOLD function, Built-in flashlight, Backlight auto-adjustment |
10. Garanție și asistență
10.1. Informații despre garanție
Sonel products are manufactured to high standards and are warranted against defects in materials and workmanship for a period specified by your regional distributor from the date of purchase. This warranty does not cover damage caused by misuse, unauthorized modification, accident, or neglect. Please retain your proof of purchase for warranty claims.
10.2. Suport tehnic
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your local Sonel distributor or the authorized service center. Contact information can typically be found on the Sonel official website sau prin punctul dvs. de vânzare.
When contacting support, please have your product model number (SON001) and purchase date readily available.