1. Introducere
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.
The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.
2. Informații de siguranță
WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
- This product must be installed and serviced by qualified electrical personnel only.
- Turn off all power to the electrical panel before working on or installing the circuit breaker.
- Folosiți întotdeauna un voltage detector to confirm power is off before touching any wires or components.
- Respectați toate codurile și reglementările electrice locale și naționale.
- Nu utilizați acest dispozitiv dacă pare deteriorat.
Nerespectarea acestor instrucțiuni va duce la moarte sau vătămări grave.
3. Produs terminatview
The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Imaginea 3.1: Faţă view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Imaginea 3.2: Latura view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Imaginea 3.3: Spate view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.
Caracteristici cheie:
- Integrare inteligentă: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
- Instalare ușoară: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
- Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
- Siguranță sporită: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.
4. Configurare și instalare
Professional installation by a qualified electrician is required.
- Prepare the Load Center: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltage tester.
- Conexiuni prin cablu: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
- Install the Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
- Sârmă de împământare: Connect the ground wire from the branch circuit to the ground bar in the load center.
- Verificați instalarea: Verificați de două ori toate conexiunile pentru a vedea dacă sunt strânse și fixate corect.
- Restabiliți puterea: Once installation is complete and verified, restore power to the load center.
For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:
Video 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.
5. Instrucțiuni de utilizare
Operare manuala:
- Pornirea: Push the breaker handle firmly to the "ON" position.
- Oprind: Push the breaker handle firmly to the "OFF" position.
- Resetarea unui întrerupător declanșat: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.
GFCI Test and Reset:
The GFCI function should be tested monthly to ensure proper operation.
- Ensure the breaker is in the "ON" position.
- Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
- To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
- If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.
Smart Features (My Leviton App):
The LB260-GS integrates with the My Leviton app, providing advanced functionality:
- Monitorizarea energiei: View real-time and historical energy consumption data for the circuit.
- Telecomanda: Turn the breaker ON or OFF remotely via the app.
- Notificări: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
- Autotestare: The smart breaker performs self-tests and reports status to the app.
Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.
6. Întreținere
- Test lunar GFCI: Perform the GFCI test as described in Section 5.
- Inspecție vizuală: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
- curatenie: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.
7. Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Disjuncătorul se deplasează frecvent. | Overload, short circuit, or ground fault. | Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists. |
| Breaker does not reset after tripping. | Persistent fault (overload, short circuit, or ground fault) or internal breaker damage. | Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician. |
| Butonul de testare GFCI nu declanșează întrerupătorul. | Faulty GFCI mechanism. | The breaker may be defective. It must be replaced by a qualified electrician. |
| No data in My Leviton app / Breaker not connecting. | Network issue, app configuration error, or data hub issue. | Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides. |
For issues not covered here, contact Leviton customer support or a qualified electrician.
8. Specificații
| Atribut | Detaliu |
|---|---|
| Marca | Leviton |
| Numărul de model | LB260-GS |
| Evaluare curentă | 60 Amps |
| Număr de poli | 2 |
| Voltage | 120 / 240 VAC |
| Tip întrerupător | GFCI (întrerupător de circuit de eroare la pământ) |
| Trip Technology | Hydraulic Magnetic |
| Evaluarea întreruperii | 10KA |
| Tip de montare | Panel Mounting (Plug-On) |
| Temperatura de operare | -40°C până la 85°C (-40°F până la 185°F) |
| Dimensiuni | 4 x 2.5 x 3.9 inci (aproximativ) |
| Greutate | 13.6 uncii |
| UPC | 078477815342 |
9. Garanție și asistență
Garantie:
This Leviton product is covered by a Garanție limitată de 10 ani. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their website-ul sau contactați asistența pentru clienți.
Asistență clienți:
For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official website-ul sau informațiile de contact furnizate împreună cu ambalajul produsului.
You can visit the official Leviton website pentru mai multe resurse: www.leviton.com