Leviton LB260-GS

Manual de instrucțiuni pentru întrerupătorul de circuit de ramificație inteligent GFCI cu 2 poli Leviton 60A (LB260-GS)

Model: LB260-GS

1. Introducere

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.

The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.

2. Informații de siguranță

WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • This product must be installed and serviced by qualified electrical personnel only.
  • Turn off all power to the electrical panel before working on or installing the circuit breaker.
  • Folosiți întotdeauna un voltage detector to confirm power is off before touching any wires or components.
  • Respectați toate codurile și reglementările electrice locale și naționale.
  • Nu utilizați acest dispozitiv dacă pare deteriorat.

Nerespectarea acestor instrucțiuni va duce la moarte sau vătămări grave.

3. Produs terminatview

The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, front view

Imaginea 3.1: Faţă view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, side view

Imaginea 3.2: Latura view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, rear view showing bus connections

Imaginea 3.3: Spate view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.

Caracteristici cheie:

  • Integrare inteligentă: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
  • Instalare ușoară: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
  • Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
  • Siguranță sporită: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.

4. Configurare și instalare

Professional installation by a qualified electrician is required.

  1. Prepare the Load Center: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltage tester.
  2. Conexiuni prin cablu: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
  3. Install the Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
  4. Sârmă de împământare: Connect the ground wire from the branch circuit to the ground bar in the load center.
  5. Verificați instalarea: Verificați de două ori toate conexiunile pentru a vedea dacă sunt strânse și fixate corect.
  6. Restabiliți puterea: Once installation is complete and verified, restore power to the load center.

For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:

Video 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.

5. Instrucțiuni de utilizare

Operare manuala:

  • Pornirea: Push the breaker handle firmly to the "ON" position.
  • Oprind: Push the breaker handle firmly to the "OFF" position.
  • Resetarea unui întrerupător declanșat: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.

GFCI Test and Reset:

The GFCI function should be tested monthly to ensure proper operation.

  1. Ensure the breaker is in the "ON" position.
  2. Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
  3. To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
  4. If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.

Smart Features (My Leviton App):

The LB260-GS integrates with the My Leviton app, providing advanced functionality:

  • Monitorizarea energiei: View real-time and historical energy consumption data for the circuit.
  • Telecomanda: Turn the breaker ON or OFF remotely via the app.
  • Notificări: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
  • Autotestare: The smart breaker performs self-tests and reports status to the app.

Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.

6. Întreținere

  • Test lunar GFCI: Perform the GFCI test as described in Section 5.
  • Inspecție vizuală: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • curatenie: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.

7. Depanare

ProblemăCauza posibilaSoluţie
Disjuncătorul se deplasează frecvent.Overload, short circuit, or ground fault.Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists.
Breaker does not reset after tripping.Persistent fault (overload, short circuit, or ground fault) or internal breaker damage.Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician.
Butonul de testare GFCI nu declanșează întrerupătorul.Faulty GFCI mechanism.The breaker may be defective. It must be replaced by a qualified electrician.
No data in My Leviton app / Breaker not connecting.Network issue, app configuration error, or data hub issue.Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides.

For issues not covered here, contact Leviton customer support or a qualified electrician.

8. Specificații

AtributDetaliu
MarcaLeviton
Numărul de modelLB260-GS
Evaluare curentă60 Amps
Număr de poli2
Voltage120 / 240 VAC
Tip întrerupătorGFCI (întrerupător de circuit de eroare la pământ)
Trip TechnologyHydraulic Magnetic
Evaluarea întreruperii10KA
Tip de montarePanel Mounting (Plug-On)
Temperatura de operare-40°C până la 85°C (-40°F până la 185°F)
Dimensiuni4 x 2.5 x 3.9 inci (aproximativ)
Greutate13.6 uncii
UPC078477815342

9. Garanție și asistență

Garantie:

This Leviton product is covered by a Garanție limitată de 10 ani. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their website-ul sau contactați asistența pentru clienți.

Asistență clienți:

For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official website-ul sau informațiile de contact furnizate împreună cu ambalajul produsului.

You can visit the official Leviton website pentru mai multe resurse: www.leviton.com

Documente conexe - LB260-GS

Preview Ghid de instalare a prizei GFCI cu montare pe șină DIN Leviton GFNT1-DIN/GFNT2-DIN
Ghid complet pentru instalarea și testarea prizelor GFCI cu montare pe șină DIN GFNT1-DIN și GFNT2-DIN de la Leviton, inclusiv instrucțiuni de cablare, măsuri de siguranță și depanare.
Preview Manual de instalare și utilizare a prizei Leviton GFCI cu porturi USB
Ghid complet pentru instalarea și operarea prizelor Leviton GFCI cu porturi USB, inclusiv instrucțiuni de cablare, avertismente de siguranță, proceduri de testare și informații despre garanție.
Preview Ghid de instalare și testare a prizei GFCI Leviton
Un ghid complet despre cum se instalează și se testează o priză Leviton SmartLock Pro GFCI, inclusiv instrucțiuni de cablare, măsuri de siguranță și sfaturi de depanare.
Preview Instalarea și testarea prizei inteligente GFCI Leviton: Un ghid complet
Instrucțiuni pas cu pas pentru instalarea și testarea prizelor Leviton Smart GFCI (modelele D2GF1, D2GF2). Aflați despre funcționalitatea GFCI, cablare, depanare și măsuri de siguranță.
Preview Leviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
Preview Leviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.