Bio Green PHX/ES

Phoenix Air Circulation Tube User Manual

Model: PHX/ES | Brand: Bio Green

1. Introducere

The Bio Green Phoenix Air Circulation Tube is an energy-efficient accessory designed to work with the Greenhouse Heater & Fan PHOENIX to minimize energy consumption and maximize effectiveness. It is intended for use specifically in fan mode to ensure even heat and air circulation throughout the greenhouse. This flexible, dependable, and easy-to-use tube can be placed on the floor or fixed to the ceiling, making it a fantastic addition to your greenhouse heating system.

Phoenix Air Circulation Tube attached to a greenhouse heater, showing its function in a greenhouse.

Image: The Phoenix Air Circulation Tube connected to a greenhouse heater, demonstrating its primary function in a greenhouse environment.

2. Informații de siguranță

Vă rugăm să citiți cu atenție toate instrucțiunile de siguranță înainte de instalare și utilizare. Nerespectarea acestor instrucțiuni poate duce la vătămări corporale sau la deteriorarea produsului.

  • Ensure the greenhouse heater/fan is turned off and unplugged before installing or performing maintenance on the air circulation tube.
  • Always use the provided mounting materials to secure the tube properly. Improper installation can lead to the tube falling and causing damage.
  • Do not obstruct the air inlets or outlets of the tube or the fan. Maintain clear pathways for air circulation.
  • Keep the tube away from sharp objects or abrasive surfaces that could puncture or tear the material.
  • This product is designed for use in greenhouses. Do not use it for purposes other than its intended use.
  • Regularly inspect the tube for any signs of wear, tear, or damage. Replace if necessary.

3. Conținutul pachetului

Verificați dacă toate componentele sunt prezente în pachet:

  • 1 x Phoenix Air Circulation Tube (118 inches in length, 8.7 inches in diameter)
  • 1 x Furtun Clamp
  • 5 x Fixing Chains
  • 5 x T-bolts with nuts and ring eyelet
Image showing the Phoenix Air Circulation Tube with its dimensions and included accessories: 5 T-bolts with nuts and rings, and 5 fixing chains.

Image: A visual representation of the Phoenix Air Circulation Tube, highlighting its dimensions (118.11 inches long, 8.66 inches diameter) and the included accessories: 5 T-bolts with nuts and rings, and 5 fixing chains.

4. Configurare și instalare

The Phoenix Air Circulation Tube can be installed either on the floor or suspended from the ceiling of your greenhouse. Choose the method that best suits your greenhouse layout and air circulation needs.

4.1 Pregătirea tubului

  1. Unroll the air circulation tube carefully.
  2. Locate the opening designed to connect to your Bio Green Phoenix Greenhouse Heater & Fan.

4.2 Connecting to the Heater/Fan

  1. Ensure your Phoenix Greenhouse Heater & Fan is turned off and unplugged.
  2. Attach the open end of the air circulation tube to the fan outlet of the heater.
  3. Secure the connection using the provided hose clamp. Strângeți clamp firmly to prevent air leakage and ensure stability.
Close-up of the Phoenix Air Circulation Tube connected to a fan, showing the hose clamp for stability and the Rainexo tarp material.

Imagine: O imagine detaliată view of the tube's connection point to the fan, illustrating the use of the hose clamp for secure attachment and highlighting the durable Rainexo® tarp material.

4.3 Opțiuni de montare

Montare pe tavan:

  1. Identify suitable anchor points in your greenhouse ceiling structure.
  2. Attach the T-bolts with nuts and ring eyelets to the designated grommets along the top edge of the air circulation tube.
  3. Use the provided fixing chains to suspend the tube from your chosen ceiling anchor points. Ensure the tube is level and securely supported along its entire length.

Amplasarea podelei:

  1. Place the tube directly on the greenhouse floor, ensuring it is positioned to facilitate optimal air distribution.
  2. Ensure the tube is not obstructing walkways or other essential greenhouse functions.
Phoenix Air Circulation Tube installed in a greenhouse, showing how it connects to the fan and distributes air for energy saving and optimal air distribution.

Image: The air circulation tube installed in a greenhouse, illustrating its connection to the fan and its role in achieving optimum and even air distribution, leading to energy savings.

5. Instrucțiuni de utilizare

The Phoenix Air Circulation Tube operates in conjunction with your Bio Green Phoenix Greenhouse Heater & Fan when the fan mode is active.

  1. Once the tube is securely installed and connected to the fan, plug in your Bio Green Phoenix Greenhouse Heater & Fan.
  2. Activate the fan mode on your heater. The fan will push air through the circulation tube.
  3. The tube's design ensures that the air is evenly distributed throughout the greenhouse, eliminating cold spots and promoting uniform temperature and humidity.
  4. This system is ideal for year-round use, providing ventilation in summer and aiding heat distribution in winter.
Diagram illustrating even air distribution within a greenhouse using the Phoenix Air Circulation Tube, showing air currents eliminating hot and cold spots.

Image: A schematic diagram demonstrating how the Phoenix Air Circulation Tube ensures even air distribution, effectively eliminating hot and cold spots and reducing drafts within the greenhouse.

Image showing the Phoenix Air Circulation Tube in a greenhouse with text indicating 'Ventilation in Summer' and 'Heating in Winter' for year-round use.

Image: The Phoenix Air Circulation Tube is suitable for year-round use, providing essential ventilation during summer months and assisting with heat distribution in winter.

6. Întreținere

Regular maintenance will ensure the longevity and optimal performance of your Phoenix Air Circulation Tube.

  • curatenie: Periodically wipe down the exterior of the tube with a damp o lavetă pentru a îndepărta praful și resturile. Nu utilizați substanțe chimice dure sau produse de curățare abrazive.
  • Inspecţie: Regularly inspect the tube for any signs of tears, punctures, or damage to the material. Check the grommets and fixing chains for wear or corrosion.
  • Verificarea conexiunii: Asigurați-vă că furtunul este închis.amp connecting the tube to the fan remains tight and secure. Re-tighten if necessary.
  • Depozitare: If storing the tube for an extended period, ensure it is clean and dry. Roll it up neatly and store it in a cool, dry place away from direct sunlight and pests.

7. Depanare

If you encounter issues with your Phoenix Air Circulation Tube, consider the following common problems and solutions:

ProblemăCauza posibilaSoluţie
Uneven Air DistributionTube not properly aligned or sagging. Obstructions in the greenhouse.Adjust the tube's position and tension using the fixing chains. Remove any obstructions. Ensure the fan is operating correctly.
Tube Detaches from FanFurtun clamp is loose or not properly secured.Re-attach the tube to the fan outlet and tighten the hose clamp cu fermitate.
Tears or Punctures in TubeContact with sharp objects or excessive tension.Small tears may be repaired with a suitable greenhouse film repair tape. For large tears or significant damage, the tube may need replacement.
Flux de aer redusTube partially collapsed or obstructed internally. Fan issue.Check the tube for internal obstructions or kinks. Ensure the fan is clean and operating at full capacity.

8. Specificații

CaracteristicăDetaliu
Numele modeluluiPhoenix Air Circulation Tube
Numărul de modelPHX/ES
MarcaBio Green
Dimensiunile produsului118.11"L x 8.6"W x 8.6"H (approx. 300 cm L x 22 cm W x 22 cm H)
MaterialRAINEXO Greenhouse Film (0.018 lb/ft²)
CuloareGri
Tip de montareCeiling Mount, Floor Mount
Componente incluse1 Air Circulation Tube, 1 Hose Clamp, 5 Chains, 5 T-bolts with nuts and ring eyelet
Greutatea articolului1.98 livre (aprox. 0.9 kg)
Utilizări specifice pentru produsGreenhouse Air Circulation

9. Garanție și asistență

For warranty information and customer support, please refer to the documentation provided with your Bio Green Phoenix Greenhouse Heater & Fan, or visit the official Bio Green webPăstrați dovada achiziției pentru orice reclamații în garanție.

For additional assistance, you may contact Bio Green customer service through their official channels.

Documente conexe - PHX/ES

Preview Bio Green Phoenix 2.8 Air Circulation Heater: Installation and Operation Manual
Comprehensive guide for installing and operating the Bio Green Phoenix 2.8 air circulation heater, including technical data, safety instructions, and usage recommendations for greenhouses and winter gardens.
Preview Bio Green PALMA TWIN Air Circulation Heater: Installation and Operating Instructions
Comprehensive installation and operating instructions for the Bio Green PALMA TWIN air circulation heater (PAL T-US), covering safety, usage modes, technical specifications, maintenance, and warranty information.
Preview Bio Green Palma 2.0 Air Circulation Heater: Installation & Operating Manual
Comprehensive guide for installing and operating the Bio Green Palma 2.0 and Palma 2.0 RAW air circulation heaters, including technical data, safety instructions, and maintenance.
Preview Încălzitor de seră Bio Green Frosty 2500 / 4500: Manual de instalare și utilizare
Manual complet de instalare și utilizare pentru încălzitoarele de seră pe gaz Bio Green Frosty 2500 și Frosty 4500. Acoperă siguranța, configurarea, funcționarea, datele tehnice și depanarea.
Preview Bio Green Palma 2.0 Installation and Operating Instructions
Comprehensive guide for the Bio Green Palma 2.0 air circulator heater, covering installation, operation, and safety precautions. Includes details for both manual and digital thermostat models.