Prity FGW15

Prity FGW15 Wood-Burning Stove with Oven and Back Boiler

Manual de utilizare

1. Introducere

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Prity FGW15 wood-burning stove with oven and back boiler. This appliance is designed to provide both room heating and hot water for central heating systems, while also offering a functional oven for cooking. Please read this manual thoroughly before using the appliance and retain it for future reference.

The Prity FGW15 stove complies with European standards EN 13240:2001 and EN 13299:2001, ensuring its quality and safety for domestic use.

2. Informații de siguranță

Instalare profesională necesară: This appliance requires professional installation by a qualified technician to ensure safe and correct operation, as well as compliance with local building codes and regulations. Improper installation can lead to fire hazards, carbon monoxide poisoning, and other serious risks.

2.1 Avertismente generale de siguranță

2.2 Minimum Clearances to Combustible Materials

Maintain the following minimum distances from combustible materials to prevent fire hazards:

These distances are critical for safety. Consult your installer for specific requirements based on your installation.

2.3 Permissible Fuel

Folosiți doar dry firewood as fuel. The wood moisture content should be 16 ± 4% according to EN 13240:2006, EN 13229:2006, EN 12815:2006 Annex B, Table B.1. Do not burn treated wood, plastics, coal, or any other materials not specified for wood-burning stoves, as this can damage the appliance, create hazardous emissions, and void your warranty.

3. Componentele produsului

The Prity FGW15 is a versatile appliance combining a wood-burning firebox, an oven, and a back boiler for central heating. Key components include:

Faţă view of Prity FGW15 wood-burning stove with oven and back boiler, showing the firebox, oven, and ash drawer.

Figura 3.1: Față view of the Prity FGW15 stove, highlighting the firebox, oven, and ash drawer.

Spate view of Prity FGW15 wood-burning stove, showing the back boiler connections and flue outlet.

Figura 3.2: Spate view of the Prity FGW15 stove, illustrating the cold and hot water connections for the back boiler and the flue pipe outlet.

4. Specificatii tehnice

Below are the detailed technical specifications for the Prity FGW15 wood-burning stove:

Prity FGW15 wood-burning stove dimensions: 93 cm height, 57 cm width, 53 cm depth.

Figure 4.1: Key dimensions of the Prity FGW15 stove.

CaracteristicăCaietul de sarcini
ModelFGW15
MarcaPrity
Dimensiuni produs (D x L x H)53 x 57 x 93 cm
Greutate136 kg
MaterialFontă
Nominal Room Heating Power5 kW
Nominal Water Heating Power15 kW
Total Nominal Heat Output19.8 kW
Capacitatea cazanului15 litri
Cold Water Inlet / Hot Water Outlet2.5 cm (1 inchi)
Diametrul conductei de fum130 mm
Eficienţă76.5%
Approximate Heating Surface Area114 m² (for room heating)
Dimensiunile focarului (L x A x Î)465 x 240 x 430 mm
Oven Dimensions (W x D x H)380 x 400 x 200 mm
Maximum Working Pressure (Water)1.25 bari
Temperatura gazelor de ardere192 °C
CO in Flue Gas1031.3 mg/Nm³ (0.0985 %)
Dust Content26.4 mg/Nm³
NOx Content102.7 mg/Nm³
CxHy Content43.8 mg/Nm³

5. Cerințe de instalare

Installation of the Prity FGW15 stove must be carried out by a certified professional in accordance with all national and local building and fire safety regulations. This includes proper chimney connection, flue pipe installation, and integration with your central heating system.

5.1 Chimney and Flue Pipe

5.2 Water Connections for Back Boiler

The back boiler requires connection to a closed or open central heating system. The cold water inlet and hot water outlet connections are 2.5 cm (1 inch). A qualified plumber must perform these connections, ensuring proper pressure relief valves, expansion tanks, and circulation pumps are installed according to system requirements and local codes.

5.3 Positioning and Clearances

Refer to Section 2.2 for minimum clearances to combustible materials. The stove must be placed on a non-combustible hearth extending beyond the appliance as required by local regulations.

6. Instrucțiuni de utilizare

Before operating, ensure all installation checks are complete and the central heating system (if connected) is filled and vented.

6.1 Starting the Fire

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place a small amount of kindling and firelighters on the cast iron grate in the firebox.
  3. Light the kindling. Once it is burning well, add small pieces of dry firewood.
  4. Close the firebox door securely.
  5. Allow the fire to establish fully before adding larger logs.

6.2 Air Control and Flame Intensity

The stove is equipped with two manual dampei:

Adjust both dampers to achieve a steady, efficient burn. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or poor draft.

6.3 Utilizarea cuptorului

The oven utilizes heat from the firebox below. The oven temperature will vary depending on the intensity of the fire. Monitor the oven temperature gauge and adjust the fire's intensity as needed for cooking. Preheat the oven thoroughly before placing food inside.

7. Întreținere

Regular maintenance is crucial for the safe and efficient operation of your Prity FGW15 stove.

7.1 Îndepărtarea cenușii

Remove ash from the ash drawer regularly, ideally before each use or when the ash bed becomes thick. Allow the stove to cool completely before removing ash. Dispose of ash in a metal container with a tight-fitting lid, away from combustible materials.

7.2 Curățarea sticlei

Clean the ceramic glass on the firebox and oven doors as needed. Use a specialized stove glass cleaner or a damp cloth dipped in fine ash (when cold) to remove soot. Avoid abrasive cleaners or tools that could scratch the glass.

7.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney must be inspected and cleaned by a qualified chimney sweep at least once a year, or more frequently if heavy use or creosote buildup is observed. Blockages can lead to dangerous chimney fires and carbon monoxide accumulation.

7.4 Inspecția generală

Periodically check all seals, hinges, and dampers for wear or damage. Ensure water connections for the back boiler are free from leaks. Replace any worn parts promptly.

8. Depanare

This section addresses common issues you might encounter with your Prity FGW15 stove.

ProblemăCauza posibilaSoluţie
Smoke entering the roomBlocked chimney/flue, insufficient draft, door opened too quickly, wet fuel.Check chimney/flue for blockages. Ensure dampers are open. Use dry fuel. Open door slowly.
Putere termică scăzutăInsufficient air supply, wet fuel, small fire, poor insulation.În aer liber dampers. Use dry, seasoned wood. Build a larger fire. Check room insulation.
Focul arde prea repedeExcessive air supply, door not sealed properly.Aerul apropiat dampers partially. Check door seals and replace if necessary.
Sticla se înnegrește rapidWet fuel, insufficient air for combustion, low burning temperature.Use dry fuel. Increase air supply. Ensure fire burns hot enough.
Central heating not heating effectivelyLow fire intensity, air in system, pump malfunction, system blockage.Increase fire intensity. Bleed radiators. Check circulation pump. Consult a plumber.

If you encounter persistent problems that cannot be resolved using this guide, contact a qualified technician or your seller for assistance.

9. Conformitate și certificări

The Prity FGW15 wood-burning stove is manufactured and tested to meet stringent European standards.

9.1 European Standards

This appliance complies with:

9.2 Etichetă de eficiență energetică

The Prity FGW15 has an energy efficiency rating of A. This label provides information on the energy performance of the appliance.

Energy efficiency label for Prity FGW15 stove, showing an A rating and heat outputs.

Figure 9.1: Energy Efficiency Label for Prity FGW15.

9.3 Declarație de performanță

A Declaration of Performance (DoP) is available, confirming the essential characteristics and performance of the product in accordance with Regulation (EU) No 305/2011.

Declaration of Performance document for Prity FGW15, detailing compliance and technical data.

Figure 9.2: English Declaration of Performance for Prity FGW15.

10. Garanție și asistență

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your seller directly. In case of technical issues, questions, or the need for spare parts, please contact the retailer from whom you purchased the Prity FGW15 stove. Ensure you have your purchase details and the product model number (FGW15) available when contacting support.

Documente conexe - FGW15

Preview Cazane Prity: Descriere tehnică, manual de instalare și utilizare
Ghid complet pentru centralele termice rezidențiale Prity, care acoperă specificațiile tehnice, procedurile de instalare, instrucțiunile de operare, întreținerea și depanarea pentru modelele cu combustibil solid și peleți.