1. Introducere
This user manual provides essential information for the proper use, maintenance, and care of your ResMed Humid Air Standard Tub. This product is designed to work with ResMed AirSense 10 and AirCurve 10 CPAP devices to provide humidification during therapy. Please read this manual thoroughly before using the product to ensure safe and effective operation.
2. Produs terminatview
The ResMed Humid Air Standard Tub (Model 37299) is a replacement water chamber for compatible ResMed CPAP and BiPAP machines. It is constructed from medical-grade plastic and designed for durability and ease of use. The tub holds water that is heated by the device to provide humidified air, enhancing comfort during sleep therapy.

Figura 2.1: Față view of the ResMed Humid Air Standard Tub, highlighting the 'Humid Air' branding and the maximum fill line indicator. This image also shows the two compatible CPAP machines, AirSense 10 and AirCurve 10, below the tub.
- Compatibilitate: Specifically designed for use with ResMed AirSense 10 and AirCurve 10 series devices.
- Material: Made from high-quality medical-grade plastic.
- Capacitate: Approximately 380 milliliters (3.8E+2 Milliliters).
3. Instrucțiuni de configurare
- Remove the Tub: If a tub is already installed, gently pull it out from the side of your ResMed AirSense 10 or AirCurve 10 device.
- Open the Tub: Press the latch on the top of the tub and lift the lid to open the water chamber.
- Umple cu apă: Fill the tub with distilled water up to the maximum fill line indicated on the tub. Nu umpleți în exces. Using distilled water helps prevent mineral buildup and prolongs the life of the tub and humidifier.
- Close the Tub: Close the lid firmly until it clicks into place, ensuring a secure seal.
- Introduceți în dispozitiv: Carefully slide the filled water tub back into the humidifier chamber of your ResMed device until it is fully seated.

Figura 3.1: De sus în jos view of the ResMed Humid Air Standard Tub, illustrating the water filling area and the 'MAX' fill line. This angle provides a clear view of the tub's design for proper water addition.
4. Instrucțiuni de utilizare
Once the Humid Air Standard Tub is correctly installed and filled with water, the humidification function of your ResMed device will be active. The device will automatically detect the presence of the tub and adjust its settings accordingly, or allow you to manually set the humidity level via the device's menu.
- Ensure the water level is always above the minimum mark before starting therapy.
- Refill the tub daily with fresh distilled water.
- If you experience condensation in your tubing or mask, you may need to adjust the humidity level or consider using a heated tube (if compatible with your device).
5. Întreținere și curățare
Regular cleaning of your Humid Air Standard Tub is crucial for hygiene and optimal performance. Follow these steps for daily and weekly cleaning:
5.1 Curățare zilnică
- Empty any remaining water from the tub.
- Wash the tub with warm water and a mild dishwashing liquid.
- Clătiți bine cu apă curată.
- Allow the tub to air dry completely out of direct sunlight before reassembling or refilling.
5.2 Curățare săptămânală
- Disassemble the tub by opening the lid and separating any removable components (if applicable).
- Soak the components in a solution of one part white vinegar to two parts water for approximately 20 minutes.
- Wash the components with warm water and a mild dishwashing liquid.
- Rinse all parts thoroughly with clean water to remove any soap or vinegar residue.
- Lăsați toate piesele să se usuce complet la aer înainte de a le reasambla.
Important: Do not use bleach, alcohol, or strong cleaning agents, as these can damage the tub material. Do not wash in a dishwasher unless explicitly stated by ResMed for this specific model.
6. Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Insufficient humidification | Water level too low; Tub not properly seated; Humidifier setting too low. | Refill water to MAX line; Ensure tub is fully inserted; Adjust humidifier setting on your device. |
| Water leaks from tub | Lid not closed properly; Tub damaged; Tub not seated correctly in device. | Ensure lid clicks shut; Inspect tub for cracks/damage (replace if damaged); Reinsert tub firmly into device. |
| Mineral deposits/discoloration | Using tap water instead of distilled water; Infrequent cleaning. | Always use distilled water; Perform weekly vinegar soak and thorough cleaning. |
7. Specificații
- Număr de model: 37299
- Material: Plastic de calitate medicală
- Capacitate: Approximately 380 ml (3.8E+2 Milliliters)
- Greutatea articolului: 0.01 uncii
- Dimensiuni pachet: 5.43 x 5.2 x 4.72 inci
- UPC: 619498372997
- Compatibilitate: ResMed AirSense 10 and AirCurve 10 series devices
8. Garanție și asistență
The ResMed Humid Air Standard Tub is manufactured by ResMed, a leading provider of sleep apnea therapy products. For specific warranty information, please refer to the documentation provided with your original ResMed device or contact ResMed customer support directly. ResMed can provide assistance with product inquiries, troubleshooting, and replacement parts.
For further assistance, please visit the official ResMed website-ul web sau contactați distribuitorii lor autorizați.