1. Introducere
This manual provides detailed instructions for the installation, operation, and maintenance of your Cadet Heating Dial Double Pole Line Voltage Thermostat, Model 08301. This thermostat is designed to control 120/208/240V electric heaters, offering reliable temperature regulation for your space. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Figura 1: Volumul liniei cu bipolare cu cadran de încălzire Cadettage Thermostat. This image displays the front view of the white thermostat with a central rotary dial for temperature adjustment. The dial is marked with temperature values in Fahrenheit, ranging from 40 to 80 degrees. The brand name "CADET" is visible at the top, and ventilation slots are present along the top and bottom edges of the unit.
2. Informații de siguranță
AVERTIZARE: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Failure to follow these instructions may result in electric shock, fire, or property damage.
- Always disconnect power at the main service panel before installing or servicing this thermostat.
- Asigurați-vă că toate conexiunile cablajului sunt sigure și izolate corespunzător.
- Do not use this thermostat with heating systems that exceed its specified voltage și amperage ratings (120/208/240V, 22A).
- Keep the thermostat dry and away from water sources.
- Do not attempt to repair or modify the thermostat. Contact qualified personnel for service.
3. Configurare și instalare
The Cadet 08301 thermostat is designed for wall-mount installation and is suitable for both new construction and replacement applications. It fits a standard outlet box.
3.1 Lista de verificare înainte de instalare
- Verificați dacă volumul termostatuluitage și amperage ratings match your heating system requirements.
- Ensure power to the heating circuit is OFF at the main breaker.
- Gather necessary tools: screwdriver, wire strippers, electrical tape.
3.2 Instrucțiuni de montare
- Carefully remove the thermostat cover.
- Mount the thermostat base to a standard electrical outlet box using the provided screws. Ensure it is level.
- Avoid mounting the thermostat near heat sources (e.g., direct sunlight, lamps, appliances) or drafts (e.g., windows, doors) to ensure accurate temperature readings.
3.3 Instrucțiuni de cablare
This is a double-pole, 4-wire thermostat. The thermostat features color-coded wires for easy installation.
- Connect the two incoming line wires (from the circuit breaker) to the two thermostat wires marked "LINE".
- Connect the two outgoing load wires (to the heater) to the two thermostat wires marked "LOAD".
- Ensure all wire nuts are tight and connections are secure.
- Carefully push the wires back into the electrical box and reattach the thermostat cover.
- Reconectați alimentarea la panoul principal de service.
4. Instrucțiuni de utilizare
The Cadet 08301 thermostat features a simple manual dial for temperature control.
- Setarea temperaturii: Rotiți butonul central în sensul acelor de ceasornic pentru a crește temperatura dorită sau în sens invers acelor de ceasornic pentru a o reduce. Intervalul de temperatură este de la 50°C la 90°C.
- Setare OFF: To turn off the heating system, rotate the dial completely counter-clockwise past the lowest temperature setting until it clicks into the "OFF" position. This disconnects power to the heater.
- Sensoarea temperaturii: The bimetal sensor with a snap-action switch will activate or deactivate the heater to maintain the set temperature.
5. Întreținere
The Cadet 08301 thermostat requires minimal maintenance to ensure optimal performance.
- curatenie: Ștergeți periodic exteriorul termostatului cu o lavetă moale și umedă.amp o lavetă. Nu folosiți substanțe de curățare abrazive sau solvenți. Asigurați-vă că nu pătrunde lichid în carcasa termostatului.
- Flux de aer: Ensure that the ventilation slots at the top and bottom of the thermostat are not obstructed by dust or debris. Blocked slots can affect temperature sensing accuracy.
- Inspecţie: Verificați anual termostatul pentru a depista orice deteriorări vizibile sau conexiuni slăbite. Dacă găsiți probleme, deconectați alimentarea și consultați un electrician calificat.
6. Depanare
Dacă întâmpinați probleme cu termostatul, consultați următorii pași comuni de depanare:
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Încălzitorul nu pornește. |
|
|
| Heater runs continuously. |
|
|
| Citire inexactă a temperaturii. |
|
|
If troubleshooting steps do not resolve the issue, contact a qualified electrician or Cadet customer support.
7. Specificații
- Model: 08301 (T522-W)
- Tip: Double Pole, 4-Wire
- Voltage: 120/208/240 volți
- AmpEvaluare epoca: 22 Amps
- Tip control: Manual Dial, Push Button (OFF setting)
- Interval de temperatură: 50°F până la 90°F
- Tip senzor: Bimetal with Snap Action Switch
- Montare: Wall Mount, fits standard outlet box
- Culoare: Alb
- Dimensiuni: Aproximativ 3.8 x 3.3 x 1.9 inci
- Greutatea articolului: 3.78 lire sterline
- Componente incluse: Senzor de temperatură
8. Garanție și asistență
For information regarding product warranty, technical support, or service, please refer to the documentation included with your purchase or visit the official Cadet Manufacturing webPăstrați dovada achiziției pentru reclamații în garanție.
Producător: CADET MANUFACTURING CO