Akicon BPT16-14EL-L12

Manual de utilizare Ventilator de evacuare pentru baie Akicon BPT16-14EL-L12 cu lumină LED

Model: BPT16-14EL-L12

Introducere

This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.

The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light

Descrierea imaginii: O față view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.

Informații de siguranță

AVERTISMENT: Pentru a reduce riscul de incendiu, șoc electric sau rănire a persoanelor, respectați următoarele:

  • Lucrările de instalare și cablarea electrică trebuie efectuate de către persoane calificate în conformitate cu toate codurile și standardele aplicabile, inclusiv codurile și standardele de construcție rezistente la incendiu.
  • Deconectați întotdeauna alimentarea de la panoul de service înainte de a conecta sau de a efectua lucrări de service la unitate.
  • This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
  • Nu utilizați acest ventilator cu niciun dispozitiv de control al vitezei în stare solidă.
  • Never place any object into the fan blades.
  • Asigurați-vă că ventilatorul este împământat corespunzător.
  • Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.

Conținutul pachetului

Verificați dacă toate componentele sunt prezente înainte de a începe instalarea:

  • Exhaust Fan Housing Assembly
  • Grille Cover with Integrated LED Light
  • 12W E26 Base LED Bulb (pre-installed or separate)
  • Materiale de instalare (șuruburi, conectori de cablu)
  • Manual de utilizare (acest document)

Specificații

CaracteristicăCaietul de sarcini
MarcaAkicon
Numărul de modelBPT16-14EL-L12
Capacitatea fluxului de aer90 de picioare cubi pe minut (CFM)
Nivel de zgomot1.5 Sunete
Sursa de alimentareAC
Voltage120 volți
Apă cu lumină LEDtage12 wați
Temperatura de culoare a luminii LED5000K (alb rece)
Dimensiuni carcasă (L x l x Î)9-3/8" x 9-3/8" x 7-5/16"
Grille Cover Size11 cm x 11 cm
Dimensiunea conducteirotund de 4 inci
Dimensiunea recomandată a camereiPână la 85 sq. ft.
CertificariHVI, cUL Listed
Greutatea articolului8.83 lire sterline

Configurare și instalare

This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.

1. Considerații prealabile instalării

  • Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
  • Deschiderea tavanului: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
  • Conducte: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
  • Cablaj electric: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.
Diagram showing housing, grille, and ceiling opening dimensions for the Akicon exhaust fan.

Descrierea imaginii: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

Installation notice for Akicon exhaust fan showing housing dimensions and required ceiling opening.

Descrierea imaginii: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.

2. Mounting the Fan Housing

  • Opriți alimentarea la întrerupătorul de circuit.
  • Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
  • Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.
Diagram illustrating attic and soffit installation types for a bathroom exhaust fan.

Descrierea imaginii: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.

3. Conexiune conductă

  • Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
  • Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.
Detailed installation diagram for the Akicon bathroom exhaust fan.

Descrierea imaginii: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.

4. Cablaje electrice

  • Open the wiring compartment on the fan housing.
  • Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
  • Ensure all connections are secure and properly insulated. Close the wiring compartment cover.

5. Install Grille Cover

  • If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
  • Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.

Once installation is complete, restore power at the circuit breaker and test the fan and light functions.

Instrucțiuni de operare

The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.

  • Funcționarea ventilatorului: Flip the designated wall switch to turn the exhaust fan ON or OFF.
  • Funcționare ușoară: Flip the designated wall switch to turn the LED light ON or OFF.
  • If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.

For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.

Întreţinere

Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.

1. Cleaning the Grille Cover

  • Gently pull down the grille cover to detach it from the housing springs.
  • Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.
A închide view of the Akicon exhaust fan grille.

Descrierea imaginii: Un detaliat view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.

2. Cleaning the Fan Interior

  • With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp pânză.
  • Do not allow water to enter the motor or electrical components.
  • Asigurați-vă că toate componentele sunt uscate înainte de a reporni alimentarea cu energie electrică.

3. LED Bulb Replacement

  • Asigurați-vă că alimentarea este oprită.
  • Remove the grille cover.
  • Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
  • Reattach the grille cover and restore power.

Depanare

If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:

ProblemăCauza posibilaSoluţie
Fan does not operate / Light does not turn onNo power supply; Loose wiring; Faulty switch; Blown fuse/tripped breakerCheck power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker.
Ventilatorul este excesiv de zgomotosLoose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ductingEnsure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages.
Performanță slabă de ventilațieDucting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacityInspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size.
LED light flickers or is dimBec slăbit; Bec defect; Problemă de cablareEnsure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light.

If the problem persists after attempting these solutions, please contact Akicon customer support.

Informații despre garanție

The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a Garanție limitată de 3 an de la data achiziției. Această garanție acoperă defectele de materiale și de fabricație în condiții normale de utilizare.

The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.

Asistență pentru clienți

For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.

Contact information can typically be found on the Akicon official website sau prin intermediul platformei dvs. de achiziții.

Documente conexe - BPT16-14EL-L12

Preview AKICON 110 CFM Bathroom Exhaust Fan with RGB LED, Humidity Sensor, 3CCT & Night Light - Use and Care Guide
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT, and night light. Includes installation instructions for new and existing construction, troubleshooting, and maintenance.
Preview Ghid de utilizare și întreținere a ventilatorului de evacuare pentru baie AKICON 110 CFM cu LED RGB și senzor de umiditate
Detailed use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan. Covers installation (new and existing construction), specifications, safety information, maintenance, troubleshooting, and remote operation for models AKHR110-RGB2-W, AKHR110-RGB2-B, and AKHR110-RGB2-S.
Preview Ventilator de evacuare pentru baie AKICON 110 CFM cu LED RGB, senzor de umiditate, 3CCT și lumină de noapte - Ghid de utilizare și întreținere
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT color temperature, and night light. Includes installation instructions, safety information, troubleshooting, and warranty details.
Preview Ventilator de baie AKICON BPT14-80CL cu lumină Ghid de utilizare și întreținere
Ghid complet de utilizare și întreținere pentru ventilatorul de baie cu lumină AKICON BPT14-80CL, care detaliază specificațiile produsului, instalarea, întreținerea, depanarea și informațiile despre garanție.
Preview AKICON AK1390N2-W/B/S Ventilator de baie cu lumină Ghid de utilizare și întreținere
Ghid complet de utilizare și întreținere pentru ventilatorul de baie AKICON AK1390N2-W/B/S cu lumină LED. Include instrucțiuni de instalare, informații de siguranță, întreținere, depanare și detalii despre garanție.
Preview Ghid de utilizare pentru comutatorul de umiditate AK-SW-FLHT
Ghid de utilizare pentru comutatorul de umiditate AKICON AK-SW-FLHT, care detaliază specificațiile, configurarea, modurile de funcționare și instrucțiunile de cablare pentru controlul ventilatoarelor și luminilor în funcție de nivelurile de umiditate.