1. Introducere
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Geko G00945 12V DC Self-Distributing Diesel Transfer Pump. Please read this manual thoroughly before using the pump to ensure proper function and to prevent injury or damage.
The Geko G00945 pump is designed for transferring diesel fuel. It is characterized by its durability and solid performance, constructed from high-quality materials.
2. Instrucțiuni de siguranță
WARNING: Failure to follow these safety instructions may result in fire, explosion, electric shock, or serious injury.
- Motorină: Handle diesel fuel with extreme care. It is flammable. Do not smoke or use open flames near the pump or fuel.
- Ventilare: Operate the pump in a well-ventilated area to avoid accumulation of fuel vapors.
- Conexiune electrică: Ensure the 12V DC power source is correctly connected (positive to positive, negative to negative). Incorrect polarity can damage the pump.
- Sursa de alimentare: Use only a 12V DC power source. Do not connect to AC power.
- Supraîncălzire: Do not run the pump dry for extended periods. Allow the pump to cool down if it becomes excessively hot.
- Întreţinere: Deconectați alimentarea înainte de a efectua orice operațiune de întreținere sau curățare.
- Copii și personal neautorizat: Nu lăsați copiii și persoanele neautorizate să se apropie de pompă în timpul funcționării.
- Echipament individual de protectie: Wear appropriate personal protective equipment (PPE) such as gloves and eye protection when handling fuel.
- Utilizare prevăzută: This pump is designed for diesel fuel transfer only. Do not use it for gasoline, alcohol, corrosive liquids, or water.
3. Produs terminatview și Componente
The Geko G00945 is a compact 12V DC self-distributing pump designed for efficient diesel transfer. Key components include the pump body, motor, inlet/outlet ports, power cables, and an on/off switch.

Figura 3.1: Înclinat view of the Geko G00945 pump, showing the red handle, motor housing, and brass hose connectors.

Figura 3.2: lateral view of the Geko G00945 pump, highlighting the pump head and mounting bracket.

Figura 3.3: Față view of the Geko G00945 pump, showing the integrated on/off switch and power cables.

Figure 3.4: Included accessories, typically consisting of hose connectors, seals, and battery clamps for power connection.
Componente incluse:
- Geko G00945 12V DC Diesel Transfer Pump
- Brass hose connectors (typically 2 units)
- Sealing rings/gaskets
- Baterie clamps (for 12V DC power connection)
- Inlet filter (strainer)
4. Configurare și instalare
- Montarea pompei:
Secure the pump to a stable, flat surface using the integrated mounting bracket. Ensure the pump is positioned to allow for proper hose routing and ventilation. Use appropriate fasteners (not always included).

Figura 4.1: Partea inferioară view showing the mounting bracket with pre-drilled holes for secure installation.
- Racord pentru furtun:
- Attach the brass hose connectors to the pump's inlet and outlet ports. Ensure sealing rings are correctly seated to prevent leaks.
- Connect a suitable suction hose (inlet) to the inlet port and a discharge hose (outlet) to the outlet port. Use hose clamps to secure all connections tightly.
- Install the inlet filter (strainer) at the end of the suction hose that will be submerged in the diesel tank. This prevents debris from entering the pump.
- Conexiune electrică:
- Ensure the pump's on/off switch is in the "OFF" position.
- Connect the red power cable from the pump to the positive (+) terminal of a 12V DC battery.
- Connect the black power cable from the pump to the negative (-) terminal of the 12V DC battery.
- Utilizați acumulatorul furnizat clamps for a secure connection. Verify polarity before proceeding.
5. Instrucțiuni de utilizare
- Preparare:
- Ensure all hose connections are secure and free of leaks.
- Place the inlet hose with the filter into the diesel source tank.
- Position the discharge hose into the receiving tank, ensuring it is securely placed to prevent spills.
- Amorsare (dacă este necesar):
This pump is self-distributing (self-priming), meaning it can draw fuel without manual priming. However, for initial use or if the pump has been run dry, it may take a few moments for fuel to flow. Ensure the inlet hose is fully submerged.
- Pornirea pompei:
Flip the on/off switch on the pump to the "ON" position. The pump will begin to operate, and fuel should start flowing shortly.
- Monitorizare:
Monitor the fuel transfer process. Do not leave the pump unattended during operation. Check for any leaks or unusual noises.
- Oprirea pompei:
Once the desired amount of fuel has been transferred, or if the source tank is empty, flip the on/off switch to the "OFF" position.
- Post-operație:
- Remove the inlet hose from the source tank.
- Allow any remaining fuel in the hoses to drain into the receiving tank or a suitable container.
- Deconectați cablurile de alimentare de la baterie.
6. Întreținere
Regular maintenance ensures the longevity and reliable performance of your Geko G00945 pump.
- Curățarea filtrului de admisie: Periodically inspect and clean the inlet filter (strainer) to remove any accumulated debris. A clogged filter can reduce pump performance.
- Inspecția furtunurilor și a conexiunilor: Regularly check all hoses and connections for signs of wear, cracks, or leaks. Replace damaged components immediately.
- Conexiuni electrice: Asigurați-vă că bateria clamps and power cable connections are clean and tight. Corroded terminals can lead to poor performance or pump failure.
- Depozitare: When not in use, store the pump in a clean, dry place, away from direct sunlight and extreme temperatures. Ensure any residual fuel is drained from the pump and hoses.
- Corpul pompei: Keep the exterior of the pump clean. Do not use harsh chemicals that could damage the housing.
7. Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Pompa nu pornește. | No power, incorrect electrical connection, faulty switch. | Check battery connections and charge. Verify correct polarity. Ensure switch is "ON". |
| Pump runs but no fuel flows. | Inlet hose not submerged, clogged inlet filter, air leak in suction line, pump not primed. | Ensure inlet hose is fully submerged. Clean filter. Check all suction line connections for tightness. Allow time for self-priming. |
| Debit redus. | Clogged inlet filter, kinked hose, low battery voltage, excessive lift height. | Clean inlet filter. Straighten hoses. Check battery voltage. Reduce lift height if possible. |
| Scurgeri de combustibil din conexiuni. | Loose connections, damaged seals/gaskets, damaged hose. | Strângeți toate furtunul clamps and connectors. Replace damaged seals or hoses. |
If problems persist after attempting these solutions, contact the manufacturer or a qualified service technician.
8. Specificații
| Caracteristică | Detaliu |
|---|---|
| Numărul de model | G00945 |
| Alimentare electrică | 12V DC |
| Aplicație | Diesel Transfer |
| Tip pompa | Self-Distributing (Self-Priming) |
| Dimensiuni pachet | 35 x 35 x 15 cm |
| Greutatea articolului | 4.25 kg |
| Producător | Firma Handlowa GEKO |
| Data primului disponibil | 5 februarie 2018 |
9. Garanție și asistență
Pentru informații despre garanție sau asistență tehnică, vă rugăm să consultați documentația furnizată odată cu achiziția sau să contactați direct producătorul. Păstrați dovada achiziției pentru reclamații în garanție.
Manufacturer: Firma Handlowa GEKO