1. Produs terminatview
The StarTech.com ICUSB234854I is an industrial-grade 4-port USB to RS232/RS485/RS422 serial adapter hub designed to add four serial communication ports to your computer. This device facilitates connection, monitoring, and control of various serial devices such as sensors, barcode scanners, and LED signage in demanding environments.
Caracteristicile cheie includ:
- Versatile Serial Protocols: Supports RS232, RS422, 4-wire RS485, and 2-wire RS485 operating modes.
- Design robust: Features an IP30-rated metal housing for durability in harsh industrial settings.
- Protecție îmbunătățită: Provides 15 kV ESD (Electrostatic Discharge) protection to prevent damage from voltage vârfuri.
- Montaj flexibil: Includes built-in wall-mounting brackets and a DIN rail mounting kit for secure installation.
- Conexiuni sigure: Equipped with screw-locking host USB-B and serial connectors to prevent accidental disconnections.
- Transfer de date de mare viteză: Utilizes high-speed UARTs for data rates up to 921.6 Kbps across all operating modes.
- Compatibilitate largă: Compatible with current and legacy Windows, Linux, macOS, and embedded platforms.

Imaginea 1.1: Înclinată view of the StarTech.com 4 Port Industrial USB to Serial Hub (ICUSB234854I), showing the four DB9 serial ports, USB-B input, and power input.
2. Conținutul pachetului
Verificați dacă pachetul dvs. conține următoarele articole:
- 1x USB Serial Hub (ICUSB234854I)
- 1x USB-B with screw lock to USB-A cable
- 1x DIN rail kit
- 1x manual de instrucțiuni

Image 2.1: Contents of the StarTech.com 4 Port Industrial USB to Serial Hub package, including the hub, USB cable, DIN rail kit, and instruction manual.
3. Componente hardware

Imaginea 3.1: Sus view of the serial hub, detailing the four DB9 serial ports (Port 1-4), individual RX/TX LEDs, and mode indicators (232, 422, 485-4, 485-2) for each port. A power LED (PWR) is also visible.
- Serial Ports (1-4): Four DB9 male connectors for connecting serial devices.
- RX/TX LEDs: Individual Receive (RX) and Transmit (TX) indicator LEDs for each serial port, showing data activity.
- Indicatori de mod: Labels (232, 422, 485-4, 485-2) next to each port indicate the configurable serial communication modes.
- LED PWR: LED indicator de putere.

Imaginea 3.2: Laterală view of the serial hub, showing the 12V DC power input and the USB-B host connection port.
- Intrare de alimentare 12V DC: Connector for an optional 12V DC power adapter (not included).
- USB-B Host Connection: Port for connecting the hub to your computer via the supplied USB-B to USB-A cable.

Imaginea 3.3: Partea de jos view of the serial hub, revealing the internal jumper settings for configuring RS232 and RS422/RS485 pinouts. This section is typically accessed for advanced configuration.
- Internal Configuration Jumpers: Located on the underside, these jumpers allow individual configuration of each serial port for RS232, RS422, or RS485 (2-wire/4-wire) modes, and termination settings. Refer to the detailed manual for specific jumper settings.
4. Configurare și instalare
4.1 Instalarea driverului
For most modern operating systems, including Windows 10/11, Linux (e.g., Ubuntu 22.04), and macOS, the necessary drivers are typically installed automatically upon connecting the device (plug-and-play). Manual driver installation is generally not required.
- Windows: The device should be recognized automatically. If not, check Device Manager for unrecognized devices and visit the StarTech.com support website for specific driver downloads.
- Linux: The device typically appears as
/dev/ttyUSB0la/dev/ttyUSB3(for ports 1-4). You can verify detection usinglsusbşidmesgcomenzi. - MacOS: Drivers are usually installed automatically.
4.2 Conexiune hardware
- Conectare la computerul gazdă: Use the provided USB-B to USB-A cable to connect the serial hub's USB-B port to an available USB port on your computer. Ensure the screw-locking mechanism is secured.
- Conexiune de alimentare: The hub can be powered via the USB connection (5V) or an optional 12V DC power adapter (not included). For applications requiring higher power output on serial port pin 9, a 12V DC power adapter is necessary.
- Conectați dispozitivele seriale: Connect your RS232, RS422, or RS485 devices to the DB9 serial ports (Port 1-4) on the hub. Secure any screw-locking connectors on your serial cables.
4.3 Port Configuration (Jumpers)
The operating mode (RS232, RS422, 4-wire RS485, 2-wire RS485) for each serial port is configured using internal jumpers located on the underside of the device. This configuration is performed physically, not through software.
- Access Jumpers: Carefully detach the hub from any mounting and access the underside panel where the jumpers are located (refer to Image 3.3).
- Configure Mode: Adjust the jumpers for each port according to the desired serial communication standard (RS232, RS422, RS485). Consult the detailed pinout and jumper setting diagrams in the full product manual for precise instructions.
- Set Termination: If required for RS422/RS485 networks, configure termination resistors using the appropriate jumpers.
- Pin 9 Power: Each serial port's Pin 9 can be configured to output 5V, 12V (requires external 12V DC power adapter), or 0V. Adjust jumpers as needed.
Nota: Incorrect jumper settings can prevent communication. Always refer to the specific pinout diagrams for your desired configuration.
4.4 Opțiuni de montare
The serial hub offers flexible mounting options:
- Montare pe perete: Utilize the built-in wall-mounting brackets for secure attachment to a flat surface.
- Montare pe șină DIN: Use the included DIN rail kit to mount the hub onto a standard DIN rail, common in industrial control panels.
5. Instrucțiuni de utilizare
Once the hub is connected and configured, it functions as a transparent serial port expander for your system. Data transmission and reception are indicated by the RX/TX LEDs for each port.
- Comunicare de date: Use your serial communication software or application to interact with the connected serial devices through the assigned COM ports (Windows) or
/dev/ttyUSBxdevices (Linux/macOS). - Monitoring Activity: Observe the RX (Receive) and TX (Transmit) LEDs on the hub. A flashing RX LED indicates data being received by the hub on that port, while a flashing TX LED indicates data being transmitted from the hub on that port.
- Rate de transmisie: The hub supports data rates up to 921.6 Kbps. Ensure your connected devices and software are configured to the correct baud rate.
6. Întreținere
The StarTech.com ICUSB234854I is designed for industrial environments and requires minimal maintenance.
- curatenie: Use a soft, dry cloth to clean the exterior of the device. Avoid using liquid cleaners or solvents, as these can damage the electronics.
- Protecția mediului: The IP30 rating provides protection against solid objects larger than 2.5mm, but it is not waterproof. Avoid exposing the device to liquids or excessive moisture.
- Protecție ESD: The 15 kV ESD protection helps safeguard the device from electrostatic discharge. However, always handle the device with care and follow standard ESD precautions when working with electronic components.
- Actualizări firmware: Verificați StarTech.com website periodically for any available firmware updates that may improve performance or compatibility.
7. Depanare
- Dispozitiv nedetectat:
- Ensure the USB cable is securely connected to both the hub and the computer.
- Încercați să conectați hub-ul la un alt port USB de pe computer.
- If using an external power adapter, ensure it is properly connected and providing power.
- Temporarily remove other serial USB devices from your system, then connect the hub and reboot if necessary.
- Check your operating system's Device Manager (Windows) or use
lsusbşidmesg(Linux) to verify device detection and driver status.
- Fără comunicare cu dispozitivul serial:
- Verify that the serial device is correctly connected to one of the hub's DB9 ports.
- Confirm that the internal jumpers for the specific port are correctly configured for the serial protocol (RS232, RS422, RS485) required by your device.
- Ensure your serial communication software is configured to the correct COM port (or
/dev/ttyUSBxdevice), baud rate, data bits, parity, and stop bits. - Check the RX/TX LEDs on the hub for activity. If no LEDs flash during communication attempts, there might be an issue with the device, cable, or software configuration.
- If using RS422/RS485, verify termination settings are correct for your network topology.
- Port Numbers Not Sequential (Linux):
- In some Linux environments, port allocations (e.g.,
/dev/ttyUSB0,/dev/ttyUSB1) may not always correspond numerically to the physical ports on the hub. This is a system-level behavior and typically does not affect functionality. You can identify which/dev/ttyUSBxcorresponds to which physical port through testing or system logs.
- In some Linux environments, port allocations (e.g.,
8. Specificații
| Numărul de model | ICUSB234854I |
| Porturi | 4 x DB9 Male Serial Ports |
| Interfață gazdă | USB 2.0 Type-B (Screw-Locking) |
| Standarde seriale | RS232, RS422, RS485 (2-wire/4-wire) |
| Max. Rata de date | 921.6 Kbps |
| Protecție ESD | 15 kV (Level 4) |
| Evaluare IP | IP30 |
| Intrare de putere | 5V via USB or 12V DC (external adapter, not included) |
| Pin 9 Power Output | 0V, 5V, or 12V (configurable) |
| Temperatura de operare | -40°C până la 85°C (-40°F până la 185°F) (Typical for industrial grade, inferred) |
| Dimensiuni produs (L x l x H) | 5 x 4.6 x 1 inchi (12.7 x 11.7 x 2.5 cm) |
| Greutatea articolului | 13.4 uncii (380 g) |
| Material | Carcasa metalica |
| Culoare | Negru |
| Opțiuni de montare | Wall-mountable, DIN Rail mountable |
| Producător | StarTech.com |
9. Garanție și suport tehnic
This StarTech.com product is backed by a 2 ani garanție.
For the most up-to-date information on warranty terms and conditions, or for technical assistance, please visit the official StarTech.com support website: