Introducere
This manual provides essential information for the proper use, maintenance, and care of your AMS 405.57 1 1/2" x 12" Aluminum Liner. This liner is designed for use with various 1-1/2" AMS core samplers, facilitating efficient and reliable sample collection.
Produs terminatview

Descrierea imaginii: A single, cylindrical aluminum tube, approximately 12 inches in length, with an outer diameter of 1 1/2 inches. The surface appears brushed or slightly textured, indicative of aluminum material. Both ends are open, showing the hollow interior of the liner. This image illustrates the primary component of the AMS 405.57 product.
The AMS 405.57 Aluminum Liner is a precision-engineered component for soil and sediment sampling. It features a 1-1/2 inch outer diameter and a 12-inch length. The wall thickness is approximately 0.060 inches, providing a balance of durability and lightweight handling. This liner is specifically designed to integrate seamlessly with compatible AMS core sampLers.
Caracteristici cheie:
- Dimensiuni: 1 1/2" outer diameter x 12" length.
- Material: High-quality aluminum construction.
- Grosimea peretelui: Aproximativ 0.060 inci.
- Compatibilitate: Designed for use with various 1-1/2" AMS core sampLers.
- Origine: Fabricat în Statele Unite.
Înființat
Before using the aluminum liner, ensure you have the appropriate AMS core sampler that is compatible with a 1-1/2 inch liner. The liner is intended to be inserted into the core sampler barrel to collect and retain soil or sediment samples.
- Inspect the Liner: Carefully examine the aluminum liner for any signs of damage, dents, or deformities that could affect its performance or fit within the core sampler.
- Clean the Liner: Ensure the interior and exterior of the liner are clean and free from debris, dirt, or residues from previous uses. Use a soft cloth and mild detergent if necessary, then rinse thoroughly and dry completely.
- Prepare Core Sampcitit: Refer to your AMS core sampler's manual for specific instructions on preparing it for liner insertion. Ensure the sampler barrel is clean and free of obstructions.
- Căptușeală de inserție: Gently slide the aluminum liner into the designated slot or barrel of your 1-1/2" AMS core sampler. Ensure it seats properly and securely. Do not force the liner, as this could cause damage to either the liner or the sampler.
- Verificare potrivire: Once inserted, confirm that the liner is flush and stable within the core sampler, ready for sampoperațiuni de ling.
Instrucțiuni de operare
The aluminum liner functions as a disposable or reusable sleeve within a core sampler to preserve the integrity of collected samples. Its operation is directly tied to the use of the core sampler itself.
- Attach Core Sampcitit: Assemble your AMS core sampler with the aluminum liner installed, following the sampler's specific instructions.
- Perform Sampling: Use the core sampler as directed by its manual to collect the desired soil or sediment sample. The liner will fill with the sample as the sampler penetrates the ground.
- Retrieve Sampcitit: Carefully extract the core sampler from the ground.
- Îndepărtați căptușeala: Once the core sampler is retrieved, gently remove the aluminum liner containing the sample. This may involve detaching the sampler's cutting tip or other components as per your sampler's design.
- Seal Samppe: Dacă sample is to be transported or stored, cap both ends of the liner immediately to prevent sample loss, contamination, or disturbance. Use appropriate end caps or sealing methods.
- Label Liner: Clearly label the liner with all necessary sample identification information (e.g., date, time, location, depth, project ID).
Nota: Always refer to the specific operating instructions of your AMS core sampler for detailed sampling procedures. The aluminum liner is a passive component designed to hold the sample.
Întreţinere
Proper maintenance extends the life of your aluminum liner, especially if intended for multiple uses, and ensures sample integritate.
- curatenie: After each use, if the liner is to be reused, thoroughly clean both the interior and exterior. Remove all soil, sediment, or other residues. Use warm water and a mild, non-abrasive detergent. A brush designed for tube cleaning may be helpful.
- Clătire: Rinse the liner thoroughly with clean water to remove all detergent residue.
- Uscare: Allow the liner to air dry completely before storage. Ensure no moisture remains inside, as this could lead to corrosion or contamination.
- Inspecţie: Regularly inspect the liner for any signs of wear, corrosion, dents, or structural damage. Even minor deformities can affect its fit and the quality of sample collection.
- Depozitare: Store liners in a clean, dry environment, away from corrosive chemicals or extreme temperatures. Keep them protected from physical impact that could cause bending or denting.
Depanare
This section addresses common issues that may arise during the use of your aluminum liner.
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Liner does not fit into core sampler. |
|
|
| Sample is difficult to extract from liner. |
|
|
| Liner gets stuck in core sampler. |
|
|
Specificații
| Atribut | Detaliu |
|---|---|
| Numărul de model | 405.57 |
| Diametrul exterior | 1 1/2 inci (aprox. 3.81 cm) |
| Lungime | 12 inci (aprox. 30.48 cm) |
| Grosimea peretelui | Approximately 0.060 inches (approx. 1.52 mm) |
| Material | Aluminiu |
| Greutate aproximativă | 1 livră (aprox. 0.45 kg) |
| Dimensiuni pachet | 14 x 4 x 4 inci |
| Producător | AMS Incorporated |
| Țara de origine | Statele Unite |
| Data primului disponibil | 12 decembrie 2017 |
Garanție și suport
Specific warranty information for the AMS 405.57 Aluminum Liner is not provided in this document. For details regarding product warranty, technical support, or replacement parts, please contact AMS Incorporated directly through their official website-ul sau canalele de servicii pentru clienți.
Producător: AMS Incorporated
Please refer to the manufacturer's official resources for the most current support information.