Notifier ISO-X

Notifier ISO-X Fault Isolator Module User Manual

Model: ISO-X

1. Introducere

The Notifier ISO-X Alarm Fault Isolator Module is designed to protect fire alarm system Signaling Line Circuits (SLC) from wire-to-wire short circuits. This module ensures that a short circuit on the SLC loop does not disable the entire loop, allowing other devices on the loop to continue functioning normally. It is an essential component for maintaining system integrity and reliability in fire detection and alarm systems.

The ISO-X module is compatible with various Notifier fire alarm control panels, including NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, and System 5000.

2. Produs terminatview

Notifier ISO-X Fault Isolator Module in its packaging

Figura 2.1: Faţă view of the Notifier ISO-X Fault Isolator Module in its original packaging. The module is white with the Notifier by Honeywell logo prominently displayed. The packaging indicates "ISO-X" and "417480".

Spate view of Notifier ISO-X Fault Isolator Module with wiring terminals

Figura 2.2: Spate view of the Notifier ISO-X Fault Isolator Module, showing the mounting bracket and wiring terminals. Labels for SLC1 and SLC2 connections are visible, along with model number, country of origin (Mexico), and UL/FM listings. Installation instructions are referenced.

3. Configurare și instalare

Installation of the ISO-X module should only be performed by qualified personnel in accordance with all local and national electrical codes, and the manufacturer's specific installation instructions (document 156-3624 referenced on the module itself).

  1. Deconectare de la curent: Ensure all power to the fire alarm control panel and associated circuits is disconnected before beginning installation.
  2. Montare: Mount the ISO-X module in a suitable location, typically within an electrical enclosure or junction box, using the provided mounting holes. Ensure proper ventilation if required by local codes.
  3. Cablaj: Connect the Signaling Line Circuit (SLC) wires to the designated terminals on the module. The module supports two SLC loops (SLC1 and SLC2) with positive (+) and negative (-) terminals for each. Refer to the wiring diagram provided with the module and the fire alarm control panel for correct polarity and connection points. The module is designed for 4-wire applications.
  4. Verificare: After wiring, visually inspect all connections to ensure they are secure and correctly terminated.
  5. Restaurarea energiei: Restore power to the fire alarm control panel and verify proper operation of the SLC loop and connected devices.

Note: The module is designed for indoor, dry applications only.

4. Funcționare

The Notifier ISO-X module operates passively within the SLC loop. In the event of a wire-to-wire short circuit on the SLC loop, the ISO-X module automatically isolates the affected segment of the loop. This isolation prevents the short circuit from disrupting communication with other devices on the healthy segments of the loop.

Once the short circuit condition is cleared, the ISO-X module automatically restores the isolated segment to normal operation, allowing full communication across the entire SLC loop without manual intervention.

5. Întreținere

The Notifier ISO-X module requires minimal maintenance. Regular system inspections and testing, as mandated by local fire codes and standards (e.g., NFPA 72), will ensure the continued proper functioning of the module and the overall fire alarm system.

6. Depanare

If a fault is indicated on the SLC loop, and the ISO-X module is suspected:

7. Specificații

AtributValoare
MarcaNotifier
Numărul de modelISO-X
Numărul pieseiISO-X
UPC636836973661
Sursa de alimentareCorded Electric (SLC Loop)
CuloareAlb
Greutatea articolului5.6 uncii
Dimensiunile produsului6 x 6 x 2 inci
Număr de articole1
AplicațieIndoor, Dry Applications Only
CompatibilitateNFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, System 5000

8. Garanție și asistență

For specific warranty information regarding your Notifier ISO-X module, please refer to the documentation provided with your purchase or contact Notifier directly. Warranty terms typically cover defects in materials and workmanship under normal use.

For technical support, installation assistance, or to report issues, please contact Notifier customer service or your authorized Notifier distributor. When contacting support, please have your product model number (ISO-X) and any relevant system information ready.

Informații de contact:

Documente conexe - ISO-X

Preview Notifier MMX-1(A), CMX-2(A), and ISO-X Fault Isolator Module Installation Instructions
Installation guide for Notifier MMX-1(A) Monitor Module, CMX-2(A) Control Module, and ISO-X Fault Isolator Module. Provides details on general description, compatibility, mounting, wiring, and testing procedures.
Preview Specificații tehnice ale modulului de monitorizare cu zece intrări Notifier XP10-M(A)
Specificații tehnice și caracteristici detaliate pentru modulul de monitorizare cu zece intrări Notifier XP10-M(A), un dispozitiv adresabil pentru sisteme de alarmă inteligente.
Preview Fișă tehnică pentru modulele de control și releu Notifier din seria FCM-1(A) și FRM-1(A)
Fișă tehnică pentru modulul de control adresabil FCM-1(A) și modulul de releu adresabil FRM-1(A) de la Notifier, care detaliază caracteristicile, aplicațiile, specificațiile și aprobările agențiilor pentru sistemele de alarmă de incendiu.
Preview Notifier FZM-1A Interface Module: Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining the Notifier FZM-1A Interface Module. Includes detailed specifications, wiring diagrams for NFPA Class B and Class A configurations, mounting instructions, and general descriptions for fire alarm systems.
Preview Notifier NCM-1 Noise Control Module: Technical Specifications and Installation Guide
Detailed technical specifications, features, and installation guidelines for the Notifier NCM-1 Noise Control Module, designed to reduce common mode noise on Signaling Line Circuits. Includes wiring specifications for AIM-200, AM2020, and AFP1010 systems.
Preview Instrucțiuni de instalare a modulului de intrare/ieșire al sistemului radio Notifier NRX-M711
Ghid complet de instalare pentru modulul radio de intrare-ieșire Notifier NRX-M711, care detaliază specificațiile, lista de piese, cablarea, programarea și punerea în funcțiune a sistemelor de alarmă de incendiu.