1. Introducere
The Kramer FC-28 is a high-performance, PoE-powered control gateway designed for seamless integration into various control systems. It provides 10 versatile ports for Serial, IR, GPI/O, and Relay control, enabling efficient management of multiple devices. This manual provides detailed instructions for the installation, operation, and maintenance of your FC-28 unit.
2. Informații de siguranță
Vă rugăm să citiți și să urmați cu atenție toate instrucțiunile de siguranță pentru a preveni deteriorarea dispozitivului sau vătămarea corporală. Păstrați acest manual pentru referințe ulterioare.
- Ensure the device is powered only by Power over Ethernet (PoE) from a compatible source.
- Nu expuneți unitatea la umezeală, ploaie sau temperaturi extreme.
- Nu deschideți c.asing; consultați personalul calificat pentru toate lucrările de service.
- Place the unit on a stable, level surface or mount it securely.
- Evitați blocarea orificiilor de ventilație pentru a preveni supraîncălzirea.
3. Conținutul pachetului
Verificați dacă pachetul dvs. conține următoarele articole:
- Kramer FC-28 10-Port Control Gateway unit
- Acest manual de utilizare
- Mounting bracket (if included with specific models)
4. Produs terminatview
The FC-28 features a compact design with clearly labeled ports for easy connectivity. Below are images illustrating the device's physical layout and typical connection scenarios.

Figura 1: Front and Rear Panel of the Kramer FC-28. The front panel typically includes status indicators, while the rear panel houses the various control ports and the Ethernet connection for PoE.

Figura 2: Example connection diagram for the Kramer FC-28. This illustrates how the gateway connects to an Ethernet network (router), RS-232 controlled devices (projector), IR emitters/blasters (Blu-ray players), GPI/O sensors, and relay-controlled devices (screen), allowing control from iOS/Android devices.
5. Configurare
5.1 Instalare fizică
The FC-28 is designed for flexible placement. Ensure the chosen location allows for adequate ventilation and easy access to ports.
- Așezați unitatea pe o suprafață plană și stabilă.
- If rack-mounting or surface-mounting, use the appropriate Kramer mounting accessories (sold separately or included with specific kits) and follow their installation instructions.
5.2 Power Connection (PoE)
The FC-28 is powered via Power over Ethernet (PoE).
- Connect an Ethernet cable from a PoE-enabled network switch or injector to the Ethernet port on the FC-28.
- The unit will power on automatically once a valid PoE connection is established. Verify the power indicator LED on the unit illuminates.
5.3 Conexiune de rețea
The Ethernet port also provides network connectivity for control and configuration.
- Ensure the Ethernet cable from the PoE source is connected to your network.
- The FC-28 will obtain an IP address via DHCP by default. Refer to the Kramer control software or network tools for device discovery and static IP configuration if required.
5.4 Connecting Control Devices
Connect your target devices to the appropriate ports on the FC-28.
- Serial (RS-232) Ports: Connect RS-232 controlled devices (e.g., projectors, displays) using standard serial cables.
- Porturi IR: Connect Kramer IR emitters or blasters to control IR-enabled devices (e.g., Blu-ray players, media players).
- GPI/O Ports: Connect sensors, buttons, or other General Purpose Input/Output devices.
- Relay Ports: Connect devices that require simple contact closure control (e.g., projector screens, blinds).
6. Instrucțiuni de utilizare
The Kramer FC-28 is primarily controlled and configured via a network connection using Kramer's control software or API commands.
6.1 Configurare inițială
Upon initial power-up and network connection, the FC-28 is ready for configuration.
- Use Kramer's network discovery tools or a web browser (if a web interface is available) to locate the FC-28 on your network.
- Access the device's configuration interface to assign static IP addresses, configure port settings (baud rates for serial, IR codes, GPI/O functions, relay states), and integrate with your control system.
6.2 Control Integration
Once configured, the FC-28 acts as a bridge between your control system and the connected devices.
- Integrate the FC-28 into your preferred control platform (e.g., Kramer Control, third-party control systems) using its API or drivers.
- Send commands through the network to the FC-28, which then translates and transmits them via the appropriate Serial, IR, GPI/O, or Relay port to control the end devices.
7. Întreținere
Regular maintenance ensures optimal performance and longevity of your FC-28.
- curatenie: Folosiți o lavetă moale și uscată pentru a curăța exteriorul unității. Nu utilizați agenți de curățare lichizi sau cu aerosoli.
- Actualizări firmware: Periodically check the Kramer website for firmware updates. Follow the provided instructions carefully for any updates to ensure compatibility and access to new features.
- Ventilare: Asigurați-vă că orificiile de ventilație nu sunt obstrucționate pentru a preveni supraîncălzirea.
8. Depanare
If you encounter issues with your Kramer FC-28, refer to the following common problems and solutions:
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Unitatea nu pornește. | No PoE connection or faulty PoE source. | Verify the Ethernet cable is securely connected to a PoE-enabled port. Check the PoE switch/injector for proper operation. |
| Cannot discover the unit on the network. | Network connectivity issue, incorrect IP settings, or firewall. | Ensure the Ethernet cable is connected. Check network settings (DHCP server, subnet). Temporarily disable firewalls for testing. Use Kramer's discovery tools. |
| Connected device is not responding to commands. | Incorrect port configuration, faulty cable, or device issue. | Verify port settings (baud rate, IR codes) in the FC-28 configuration. Check the cable connection to the controlled device. Ensure the controlled device is powered on and functioning correctly. |
| Control intermitent. | Network interference or loose connections. | Check for network congestion or interference. Ensure all cables are securely connected. |
If the problem persists, contact Kramer technical support for further assistance.
9. Specificații
The following specifications are for the Kramer FC-28 10-Port Control Gateway:
- Număr de model: FC-28
- Marca: Kramer
- Conectivitate: 10-Port (Serial, IR, GPI/O, Relay), Ethernet (PoE)
- Putere: Alimentare prin Ethernet (PoE)
- Dimensiuni produs (L x l x H): 9 x 6 x 6 inci
- Greutate: Aproximativ 2 de lire sterline
- Evaluare de protecție internațională: IP54
- Protocol de conectivitate: X-10 (Note: This may refer to a generic control capability; specific control protocols are typically managed via Kramer's software.)
- UPC: 642892774531
- Producător: Kramer
- Data primului disponibil: 11 octombrie 2016
10. Garanție și asistență
For warranty information and technical support, please refer to the official Kramer Electronics website or contact your authorized Kramer dealer. Keep your purchase receipt as proof of purchase.
Kramer Website: www.kramerav.com