Fluke 115

Manual de utilizare pentru multimetrul digital compact True-RMS Fluke 115

Model: 115

Introducere

This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your Fluke 115 Compact True-RMS Digital Multimeter. Please read this manual thoroughly before using the device to ensure proper functionality and safety.

Informații de siguranță

AVERTIZARE:

To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the product. Failure to follow these instructions could result in severe injury or death.

Conținutul pachetului

The Fluke 115 Digital Multimeter package typically includes the following items:

Produs terminatview

The Fluke 115 is a compact True-RMS digital multimeter designed for field service technicians. It provides accurate measurements for various electrical parameters in commercial and light industrial applications.

Multimeter and Carrying Case

Fluke 115 Digital Multimeter and C35 Soft Carrying Case

Image: The Fluke 115 Digital Multimeter (left) shown alongside its included Fluke C35 Polyester Soft Carrying Case (right). The multimeter is yellow and black with a digital display showing '600.0 V AC'. The carrying case is black with a yellow top flap featuring the 'FLUKE' logo.

Comenzi și conectori

The Fluke 115 features a large backlit display, a rotary switch for function selection, and input jacks for test leads.

Înființat

Instalare/Înlocuire baterie

The Fluke 115 typically comes with a 9V battery pre-installed. If the battery needs replacement or installation:

  1. Turn the multimeter OFF and disconnect all test leads from the device and any circuits.
  2. Localizați capacul compartimentului bateriei pe spatele multimetrului.
  3. Use a screwdriver to remove the screw securing the battery compartment cover.
  4. Scoateți cu grijă capacul.
  5. Replace the old 9V battery with a new one, ensuring correct polarity (+ to + and - to -).
  6. Reinstall the battery compartment cover and secure it with the screw.

Conectarea cablurilor de testare

Always connect the common (black) test lead to the COM jack first. Then, connect the red test lead to the appropriate function jack (VΩHzCAP or A) for your intended measurement. When disconnecting, remove the red test lead first, then the black test lead.

Instrucțiuni de operare

Măsurarea AC/DC Voltage (V~ / V-)

  1. Rotiți comutatorul rotativ la poziția V~ (Volum ACtage) sau V- (Volum CCtage) poziţia.
  2. Connect the black test lead to the COM jack and the red test lead to the VΩHzCAP jack.
  3. Conectați sondele de testare la circuitul sau componenta care urmează să fie măsurată.
  4. Citiți voltagvaloarea afișată pe ecran.

Measuring Resistance (Ω) and Continuity

  1. Turn the rotary switch to the Ω (Resistance) position.
  2. Connect the black test lead to the COM jack and the red test lead to the VΩHzCAP jack.
  3. Ensure the circuit or component is de-energized before connecting the test probes across it.
  4. Read the resistance value. For continuity, the multimeter will emit an audible beep if the resistance is below a certain threshold.

Measuring Current (A~ / A-)

  1. Turn the rotary switch to the A~ (AC Current) or A- (DC Current) position.
  2. Connect the black test lead to the COM jack and the red test lead to the A jack.
  3. AVERTIZARE: To avoid personal injury or damage to the multimeter, do not attempt to measure current in a circuit where the potential to ground exceeds 600V. Always connect the multimeter in series with the load.
  4. Deschideți circuitul în care doriți să măsurați curentul și conectați multimetrul în serie cu sarcina.
  5. Citiți valoarea curentă de pe afișaj.

Measuring Frequency (Hz) and Capacitance (CAP)

To measure frequency or capacitance, turn the rotary switch to the respective Hz or CAP position. The connection method is similar to voltage and resistance measurements, respectively, using the VΩHzCAP and COM jacks. Ensure capacitors are discharged before measuring capacitance.

Testul diodei

The diode test function allows for checking the forward voltage drop of a diode. Turn the rotary switch to the diode symbol. Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage drop in volts.

Întreţinere

Curatenie

Wipe the case of the multimeter with a damp cloth and a mild detergent. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic. If necessary, clean the input jacks with cotton swabs lightly moistened with isopropyl alcohol.

Înlocuirea bateriei

Refer to the "Battery Installation/Replacement" section under Setup for detailed instructions on replacing the 9V battery.

Depozitare

When not in use, store the multimeter and its accessories in the provided carrying case in a dry, dust-free environment. If storing the multimeter for extended periods (e.g., more than one month), it is recommended to remove the battery to prevent potential leakage and damage to the device.

Depanare

ProblemăCauza posibilaSoluţie
Fără afișaj sau afișaj slab iluminatBaterie descărcată sau descărcatăÎnlocuiți bateria de 9V.
Citiri incorecteFuncție/interval selectat incorect; Cabluri de testare deteriorate; Mufe de intrare murdareVerify the correct function and range are selected. Inspect and replace damaged test leads. Clean input jacks if necessary.
Multimeter does not respond during current measurementInternal fuse blown (for current measurements)The current input is protected by a fuse. If the fuse is blown, the multimeter will not measure current. Consult a qualified service technician for fuse replacement. Do not attempt to replace the fuse yourself unless you are qualified.
Display shows "OL" (Overload)Measurement exceeds selected range or meter's maximum capabilitySelectați un interval mai mare sau asigurați-vă că măsurătoarea se încadrează în specificațiile contorului.

Specificații

Garanție și suport

For detailed warranty information, technical support, and service inquiries, please refer to the official Fluke website or contact Fluke customer service directly. It is recommended to retain your purchase receipt as proof of purchase for warranty claims.

Documente conexe - 115

Preview Multimetre digitale Fluke 114, 115, 116, 117: Manual de utilizare și specificații
Specificații detaliate, caracteristici și ghid de utilizare pentru multimetrele digitale True-rms Fluke 114, 115, 116 și 117, care acoperă siguranța, funcționarea, întreținerea și datele tehnice.
Preview Manual de utilizare pentru multimetrul Fluke 116 True-RMS
Manual de utilizare pentru multimetrul Fluke 116 True-rms, care prezintă caracteristicile, funcționarea, măsurătorile, întreținerea și specificațiile sale. Aflați cum să utilizați acest multimetru digital versatil pentru diverse sarcini de testare electrică.
Preview Multimetru Fluke 116 True-RMS: Ghid de referință rapidă
Ghid de referință rapidă pentru multimetrul Fluke 116 True-rms, care detaliază funcțiile, capacitățile de măsurare și utilizarea sa pentru testarea electrică.
Preview Fluke 287/289 True-rms Digital Multimeters User Manual
Comprehensive user manual for the Fluke 287 and 289 True-rms Digital Multimeters, covering features, operation, safety, maintenance, and specifications.
Preview Fluke 381 Afișaj la distanță True-RMS Clamp Manual de utilizare al contorului
Manual de utilizare complet pentru Fluke 381 cu afișaj la distanță True-rms Clamp Aparat de măsurare. Acoperă caracteristicile produsului, procedurile de măsurare pentru curent alternativ/continuu, vol.tage, rezistență, frecvență, curent de pornire, întreținere, specificații și informații despre siguranță. Include descrieri detaliate ale diagramelor și tabelelor.
Preview Multimetrul Fluke 110 True-RMS: Specificații tehnice și caracteristici
Specificații și caracteristici detaliate ale multimetrului compact True-RMS Fluke 110, conceput pentru instalare și depanare electrică precisă. Include precizie, clasificări de siguranță și accesorii incluse.