1. Introducere
This instruction manual provides essential information for the proper installation, operation, and maintenance of the GPI 119200-551 Replacement Motor. This motor is designed to extend the service life of GPI M-150S Series fuel transfer pumps. Please read this manual thoroughly before attempting any installation or service to ensure safe and efficient use.
2. Informații de siguranță
AVERTISMENT: Nerespectarea acestor instrucțiuni de siguranță poate duce la vătămări corporale grave sau daune materiale.
- Always disconnect power to the fuel transfer pump before installing or servicing the motor.
- Ensure the work area is well-ventilated and free from ignition sources when working with fuel systems.
- Purtați echipament individual de protecție (EIP) adecvat, inclusiv ochelari de protecție și mănuși.
- Refer to the original fuel transfer pump manual for additional safety guidelines specific to the pump assembly.
- This motor is designed for use with specific GPI M-150S Series fuel transfer pumps and should not be used for other applications.
3. Produs terminatview
The GPI 119200-551 is an OEM replacement motor specifically engineered for GPI M-150S Series fuel transfer pumps. It is designed to restore the performance and extend the operational life of your pump.

Imaginea 1: GPI 119200-551 Replacement Motor. This image displays the cylindrical motor with a silver mounting plate, a central shaft, and red and black electrical wires extending from the side.
Caracteristici cheie:
- Performanţă: 1900 RPM, 1/5 Horsepower, 12V DC.
- Standarde de siguranță: UL listed to US and Canadian Standards.
- Calitate: Genuine GPI part, tested and approved for use with GPI fuel transfer pumps.
- Origine: Fabricat în SUA.
Compatibilitate:
This replacement motor is compatible with the following GPI M-150S Series fuel transfer pump models:
- GPI M-150S-AU
- GPI M-150S-MU
- GPI M-150S-EM
- GPI M-150S-PO
- GPI M-150S-E-PO
4. Configurare și instalare
Installation of the replacement motor requires careful attention to detail. It is recommended to consult the original pump's owner's manual for specific disassembly and reassembly instructions. The following steps provide a general overview:
- Deconectați alimentarea: Ensure the fuel transfer pump is completely disconnected from its power source (e.g., vehicle battery, power supply).
- Goliți combustibilul: If necessary, drain any remaining fuel from the pump and hoses to prevent spills.
- Motor de acces: Carefully disassemble the pump housing to gain access to the existing motor. Note the orientation and connection points of the old motor.
- Scoateți motorul vechi: Disconnect electrical wiring and mounting hardware from the old motor. Remove the old motor from the pump assembly.
- Instalați motorul nou: Position the new GPI 119200-551 replacement motor into the pump housing, ensuring proper alignment with the pump's internal components.
- Conectare cablare: Connect the electrical wires (red and black) to the corresponding terminals. Ensure secure and correct polarity.
- Motor securizat: Fasten the new motor using the appropriate mounting hardware. Ensure all connections are tight.
- Reassemble Pump: Reassemble the pump housing, ensuring all seals and gaskets are correctly seated to prevent leaks.
- Funcționare de testare: Reconnect power to the pump and perform a functional test with a non-flammable liquid (e.g., water) to check for proper operation and leaks before introducing fuel.
For detailed visual guides or specific model instructions, refer to the official GPI website-ul sau contactați asistența pentru clienți.
5. Funcționare
Once the GPI 119200-551 replacement motor is correctly installed, the fuel transfer pump will operate according to its original specifications. Refer to your specific GPI M-150S Series fuel transfer pump's owner's manual for detailed operating procedures, including:
- Amorsarea pompei.
- Connecting hoses and nozzles.
- Activating and deactivating the pump.
- Safety precautions during fuel transfer.
The replacement motor ensures the pump delivers consistent performance for efficient fuel transfer.
6. Întreținere
The GPI 119200-551 replacement motor is designed for durability and minimal maintenance. However, regular inspection of the overall pump system is crucial for longevity and safe operation.
- Inspecția motorului: Periodically check the motor for any signs of damage, excessive heat, or unusual noise during operation.
- Conexiuni electrice: Asigurați-vă că toate conexiunile electrice rămân strânse și fără urme de coroziune.
- Curăţenie: Keep the motor and pump exterior clean and free from dirt, debris, and fuel residue.
- Pump System Maintenance: Follow the maintenance schedule outlined in your GPI M-150S Series fuel transfer pump's owner's manual for other components like hoses, nozzles, and filters.

Imaginea 2: GPI Spare Parts and Accessories. This image shows a GPI fuel pump nozzle attached to a pump on a green tractor, with text indicating that GPI offers a full line of spare parts and accessories for pump repair and performance enhancement.
7. Depanare
If your fuel transfer pump experiences issues after motor replacement, consider the following common troubleshooting steps. Always disconnect power before inspecting or servicing.
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Pompa nu pornește. | No power supply; loose electrical connections; faulty switch. | Check power source and fuses. Verify all electrical connections are secure. Inspect the pump's power switch. |
| Motor runs but no fuel is dispensed. | Pump not primed; clogged inlet/outlet; air leak in suction line. | Ensure pump is properly primed. Check for obstructions in hoses or nozzle. Inspect suction line for leaks. |
| Debit redus. | Clogged filter; worn pump components (not motor related); low voltage. | Clean or replace fuel filter. Check battery voltage if 12V DC. Consult pump manual for internal component inspection. |
| Unusual noise from motor. | Foreign object; motor bearing issue; improper installation. | Disconnect power and inspect for obstructions. If noise persists, contact GPI support. |
If troubleshooting steps do not resolve the issue, contact GPI customer support for further assistance.
8. Specificații
| Atribut | Detaliu |
|---|---|
| Numărul de model | 119200-551 |
| Marca | GPI (Great Plains Industries) |
| Voltage | 12V DC |
| Cai putere | 1 / 5 HP |
| RPM | 1900 RPM |
| Material | Aluminiu |
| Dimensiuni (L x l x H) | 12 x 6 x 7 inci |
| Greutatea articolului | 6.43 lire sterline |
| Tip de potrivire | Universal Fit (for specified M-150S Series pumps) |
| Tipul de service al vehiculului | Truck, Tractor, Heavy Machinery |
| Compatibilitatea tipurilor de gaz | Benzină |
| Certificari | Listă UL conform standardelor americane și canadiene |
| UPC | 031401002768 |
9. Informații despre garanție
GPI Genuine Parts & Accessories, including the 119200-551 Replacement Motor, are backed by a Garanție limitată de 90 de zile a producătorului. Această garanție acoperă defectele de materiale și de manoperă în condiții normale de utilizare.
For specific warranty terms and conditions, or to make a warranty claim, please refer to the documentation included with your product or visit the official Great Plains Industries website-ul.
10. Asistență și contact
For technical assistance, troubleshooting guidance, or inquiries regarding replacement parts, please contact Great Plains Industries customer support.
- Suport produs: Available by phone on weekdays.
- Manuale de utilizare: All GPI owner's manuals are available for download on the official Great Plains Industries website-ul.
- Website: www.gpipumps.com
Când contactați serviciul de asistență, vă rugăm să aveți la îndemână numărul modelului produsului (119200-551) și orice informații relevante despre achiziție.