Introducere
The Welch Allyn 767 Wall Aneroid is a blood pressure monitor designed for accurate and reliable readings in clinical settings. Its improved ergonomics and modern design enhance usability. This manual provides essential information for the proper setup, operation, and maintenance of your device.
Caracteristici cheie
- Laser-engraved dial face: Provides unmatched accuracy for precise readings.
- Recessed dial face and high-contrast red pointer: Increases visibility and reduces parallax errors, ensuring clear interpretation of results.
- New 5-leg stand: Offers improved stability and maneuverability. (Note: While this feature is listed for the product line, for this wall-mounted model, stability refers to its secure wall attachment.)
- Simple color changes: Gives the aneroid a refreshed aesthetic.
- Fără mercur: Environmentally friendly and safer for clinical use.
Produs terminatview

Figure 1: Welch Allyn 767 Wall Aneroid Blood Pressure Monitor.
This image displays the Welch Allyn 767 Wall Aneroid blood pressure monitor. It features a large, square black dial with white markings for blood pressure readings, housed in a light-colored square casing. Below the dial, a black inflation bulb and a long, black coiled tubing are visible, connecting the unit to a cuff (not shown). The entire unit is designed for wall mounting.
Componente:
- Aneroid Gauge: The main display unit with a laser-engraved dial and high-contrast red pointer.
- Inflation Bulb: Used to inflate the blood pressure cuff.
- Coiled Tubing: Connects the gauge to the inflation bulb and the blood pressure cuff.
- Suport de montare pe perete: Secures the aneroid to the wall.
Instrucțiuni de configurare
- Alegeți locația: Select a suitable wall location, preferably near the examination area, ensuring it is at eye level for easy reading.
- Montare: Securely attach the wall mount bracket to a sturdy wall stud or use appropriate wall anchors. Ensure the bracket is level before tightening screws.
- Attach Aneroid: Carefully slide the Welch Allyn 767 Aneroid onto the mounted bracket until it clicks securely into place.
- Tubul de conectare: Connect the coiled tubing from the aneroid to the blood pressure cuff. Ensure all connections are snug to prevent air leaks.
- Verificare inițială: Before first use, perform a quick visual inspection to ensure all components are intact and properly connected.
Instrucțiuni de operare
Urmați acești pași pentru măsurarea precisă a tensiunii arteriale:
- Poziționarea pacientului: Have the patient sit comfortably with their arm supported at heart level. Ensure they are relaxed and have not exercised or consumed caffeine/nicotine recently.
- Plasarea manșetei: Select the appropriate size blood pressure cuff. Wrap the cuff firmly around the patient's bare upper arm, ensuring the artery marker on the cuff aligns with the brachial artery.
- Inflația: Close the air release valve on the inflation bulb. Rapidly inflate the cuff by squeezing the bulb until the gauge reads approximately 20-30 mmHg above the patient's usual systolic pressure, or until the radial pulse is no longer palpable.
- Deflation and Reading: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second.
- Presiunea sistolica: Note the reading on the aneroid gauge when you first hear the Korotkoff sounds (a tapping sound).
- Presiune diastolică: Note the reading when the Korotkoff sounds disappear or become muffled.
- Eliberare aer: Fully open the air release valve to deflate the cuff completely.
- Repeat Measurement: If necessary, wait at least 1-2 minutes before taking another reading on the same arm.
Întreţinere
Proper maintenance ensures the longevity and accuracy of your Welch Allyn 767 Wall Aneroid.
- curatenie: Wipe the aneroid gauge and tubing with a soft cloth dampened with a mild disinfectant solution. Do not immerse the unit in liquid.
- Depozitare: When not in use, ensure the cuff is neatly stored and the tubing is not kinked or stretched.
- Calibrare: Regular calibration is crucial for maintaining accuracy. Consult a qualified service technician for annual calibration checks or if you suspect inaccurate readings.
- Inspecţie: Periodically inspect the tubing for cracks or leaks, and the inflation bulb for proper function.
Depanare
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Lecturi inexacte | Cuff size incorrect, improper cuff placement, air leak, device needs calibration. | Ensure correct cuff size and placement. Check for leaks in tubing/cuff. Schedule professional calibration. |
| Cuff Does Not Inflate | Air release valve open, leak in tubing/cuff, faulty inflation bulb. | Close valve. Check all connections for leaks. Replace faulty components if necessary. |
| Gauge Needle Jumps Erratically | Rapid cuff deflation, patient movement, internal gauge issue. | Deflate cuff slowly (2-3 mmHg/sec). Ensure patient stillness. Contact service if issue persists. |
Specificații
- Număr de model: WEL7670-02
- Dimensiuni (pachet): 8.1 x 7.4 x 7.1 inci
- Greutate (pachet): 2.15 lire sterline
- Lungimea tubului: 8' Coiled Tubing
- Tip: Wall Aneroid Blood Pressure Monitor
- Producător: Welch Allyn
Garanție și suport
For warranty information, technical support, or service inquiries regarding your Welch Allyn 7670-02 Wall Aneroid, please contact the manufacturer directly.
Contact producator:
- Marca: Welch Allyn
- Telefon: 1-800-535-6663
- Website: www.welchallyn.com (Please note: This is a generic link and may not be the exact support page. Refer to product packaging for precise contact details.)
Always refer to the official Welch Allyn website or documentation for the most current warranty terms and support procedures.