Leviton GFRBF-T

Manual de instrucțiuni Leviton SmartlockPro GFCI cu față neagră (GFRBF-T)

Brand: Leviton | Model: GFRBF-T

1. Introducere

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton SmartlockPro Blank Face Ground Fault Circuit Interrupter (GFCI). The SmartlockPro self-test GFCI is designed to continuously monitor for ground faults, providing protection against electric shock. It features an automatic internal self-test function and a slim profile pentru o instalare mai ușoară.

2. Caracteristici cheie

  • Funcția de autotestare: Regularly conducts an automatic internal test to confirm proper ground fault response.
  • Protecție continuă: Detects and trips on actual ground faults even during self-testing.
  • Indicator luminos de stare: Provides clear feedback on power and protection status, including line/load reversal.
  • Resetare blocare: Patented mechanism prevents resetting if the GFCI is damaged or cannot respond to a ground fault.
  • Design subțire: Reduced depth facilitates easier installation in various electrical boxes.

3. Informații de siguranță

WARNING: To avoid fire, shock, or death; turn OFF power at the circuit breaker or fuse box and test that power is OFF before wiring!

  • This device must be installed by a qualified electrician or a knowledgeable individual familiar with electrical wiring.
  • Respectați întotdeauna codurile electrice locale și naționale.
  • Nu utilizați acest dispozitiv dacă pare deteriorat.
  • Asigurați o împământare adecvată.
  • Testați GFCI lunar pentru a vă asigura că funcționează corect.

4. Configurare și instalare

The Leviton SmartlockPro GFCI is designed for quick and easy installation due to its slim profile, allowing more room in the electrical box. Ensure power is OFF at the circuit breaker before beginning installation.

4.1 Conexiuni de cablare

Properly identify LINE and LOAD wires. The LINE wires bring power from the circuit breaker, and the LOAD wires carry power to downstream outlets protected by this GFCI. Incorrect wiring will prevent the GFCI from providing ground fault protection.

Latura view of the Leviton Blank Face GFCI, highlighting its slim design and wiring terminals.

Imagine: Laterală view of the Leviton Blank Face GFCI, showing its slim profile and wiring terminals for connection.

4.2 Ghid video de instalare

Video: This official Leviton video demonstrates the easy installation process for a GFCI outlet, highlighting its slim design and wiring connections.

5. Instrucțiuni de utilizare

The Blank Face GFCI provides ground fault protection in areas where a standard receptacle is not needed, such as for hard-wired appliances or in conjunction with other protected outlets.

5.1 Self-Test and Indicator Light

The SmartlockPro GFCI continuously monitors its own functionality. A green LED indicator light confirms that the device is working correctly and providing protection. If the LED turns red or does not illuminate, the GFCI may be faulty and requires attention.

Faţă view of the Leviton Blank Face GFCI with visible TEST and RESET buttons.

Imagine: față view of the Leviton Blank Face GFCI, showing the TEST and RESET buttons and the LED indicator light.

5.2 Monthly Testing

Even with the self-test feature, it is important to manually test your GFCI monthly to ensure it is functioning correctly. To test:

  1. Apăsați tasta TEST button. The GFCI should trip, and the indicator light may change or turn off.
  2. Apăsați tasta RESET button. The GFCI should reset, and the indicator light should return to green.

If the GFCI does not trip or reset as described, it may be faulty and should be replaced.

6. Întreținere

Regular maintenance for your Leviton GFCI involves monthly manual testing and visual inspection. Ensure the device is free from physical damage, discoloration, or loose connections. If any issues are observed, refer to the troubleshooting section or contact a qualified electrician.

7. Depanare

7.1 GFCI Trips Frequently

If your GFCI trips, it is performing its intended safety function by detecting a ground fault. To identify the cause:

  • Inspect the GFCI: Check for any signs of discoloration, burning, or loose connections. If found, replace the GFCI immediately.
  • Identificați cauza: Note what was happening when the GFCI tripped. Were you using a specific appliance? Did you plug something in or turn something on?
  • Check Appliances/Cords: Visually inspect any connected appliances or their cords for damage (e.g., frayed wires). Unplug any device with obvious damage or faults.
  • Resetați: After addressing potential causes, press the RESET button. If it resets, the issue was likely with the appliance or cord.
  • Declanșare persistentă: If the GFCI continues to trip, or if the reason for the trip is not obvious, it is time to contact a qualified electrician.

7.2 GFCI Troubleshooting Video

Video: This official Leviton video explains what to do when your GFCI outlet trips and when it's appropriate to call an electrician.

8. Specificații

Caietul de sarciniValoare
Numărul de model al articoluluiGFRBF-T
Dimensiunile produsului1.69 x 1.32 x 4.21 inci; 3.2 uncii
MarcaLeviton
CuloareMigdală ușoară
MaterialPolicarbonat (PC)
Voltage125 volți
ProducătorLeviton Direct
Data primului disponibil5 august 2015

9. Garanție și asistență

Leviton products are backed by a manufacturer's warranty. For specific warranty details, technical support, or further assistance, please refer to the documentation included with your product or visit the official Leviton website. Se recomandă păstrarea dovezii de achiziție pentru reclamațiile în garanție.

Documente conexe - GFRBF-T

Preview Ghid de instalare și testare a prizei Leviton SmartlockPro GFCI
Ghid complet pentru instalarea și testarea prizelor Leviton SmartlockPro cu întrerupător de circuit de defect la masă (GFCI). Acoperă măsurile de siguranță, cablarea, depanarea și caracteristicile produsului.
Preview Ghid de instalare și testare a prizei GFCI Leviton
Un ghid complet despre cum se instalează și se testează o priză Leviton SmartLock Pro GFCI, inclusiv instrucțiuni de cablare, măsuri de siguranță și sfaturi de depanare.
Preview Ghid de instalare a prizei GFCI cu montare pe șină DIN Leviton GFNT1-DIN/GFNT2-DIN
Ghid complet pentru instalarea și testarea prizelor GFCI cu montare pe șină DIN GFNT1-DIN și GFNT2-DIN de la Leviton, inclusiv instrucțiuni de cablare, măsuri de siguranță și depanare.
Preview Manual de instalare și utilizare a prizei Leviton GFCI cu porturi USB
Ghid complet pentru instalarea și operarea prizelor Leviton GFCI cu porturi USB, inclusiv instrucțiuni de cablare, avertismente de siguranță, proceduri de testare și informații despre garanție.
Preview Instalarea și testarea prizei inteligente GFCI Leviton: Un ghid complet
Instrucțiuni pas cu pas pentru instalarea și testarea prizelor Leviton Smart GFCI (modelele D2GF1, D2GF2). Aflați despre funcționalitatea GFCI, cablare, depanare și măsuri de siguranță.
Preview Catalog Leviton L-100: Dispozitive de cablare și comenzi de iluminat pentru construcții și întreținere
Explore the comprehensive Leviton L-100 catalog, featuring a vast selection of high-quality wiring devices, lighting controls, and electrical solutions for industrial, commercial, and residential applications. Discover Leviton's century of innovation and commitment to quality.