1. Introducere
This manual provides essential information for the proper handling, installation, operation, and maintenance of the Scotsman 11-0564-01 Dump Valve Solenoid. This component is a genuine OEM (Original Equipment Manufacturer) replacement part designed for Scotsman Ice Machines. Adherence to these instructions ensures safety, reliability, and optimal performance of the part within its intended application.
2. Informații de siguranță
Always observe the following safety precautions when working with electrical and plumbing components:
- Deconectați alimentarea: Ensure all power to the appliance is disconnected before beginning any installation, maintenance, or repair work.
- Personal calificat: Instalarea și service-ul trebuie efectuate numai de către personal calificat și autorizat.
- Echipament individual de protecție (EIP): Wear appropriate PPE, such as safety glasses and gloves, to prevent injury.
- Închiderea alimentării cu apă: Turn off the water supply to the appliance before working on any plumbing components.
- Piese originale: Use only genuine OEM parts for replacements to ensure compatibility and maintain appliance integrity.
3. Produs terminatview
The Scotsman 11-0564-01 Dump Valve Solenoid is a critical component in Scotsman Ice Machines, responsible for controlling the drainage of water. This solenoid valve is designed to meet the exact specifications of the original equipment, ensuring proper fit and function.

Figura 1: Scotsman 11-0564-01 Dump Valve Solenoid. This image shows the black plastic valve body with two hose connections and the attached metal bracket with a blue electrical coil housing.
4. Configurare și instalare
Installation of the 11-0564-01 Dump Valve Solenoid should be performed by a qualified technician familiar with Scotsman Ice Machine systems. The following steps provide general guidance:
- Preparare: Disconnect power to the ice machine and shut off the water supply. Allow the machine to cool if it has been recently operating.
- Acces: Locate the existing dump valve solenoid within the ice machine. This may require removing access panels.
- Eliminare: Carefully disconnect the electrical wiring and any water hoses or fittings attached to the old solenoid. Note their positions for reinstallation. Remove the mounting hardware securing the old solenoid.
- Installation of New Solenoid: Position the new Scotsman 11-0564-01 solenoid in the same location as the old one. Secure it with the appropriate mounting hardware.
- Conexiuni: Reconnect the water hoses/fittings and electrical wiring to the new solenoid, ensuring all connections are secure and properly sealed to prevent leaks.
- Testare: Restore water supply and power to the ice machine. Observe the dump valve operation during the machine's cycle to ensure it functions correctly and there are no leaks.
Refer to your specific Scotsman Ice Machine service manual for detailed, model-specific installation instructions and diagrams.
5. Funcționare
The 11-0564-01 Dump Valve Solenoid operates automatically as part of the ice machine's cycle. When energized, the solenoid opens the valve, allowing water to drain from the ice machine's reservoir or trough. When de-energized, the valve closes, retaining water for the ice-making process. Its function is integral to maintaining water quality and preventing mineral buildup within the machine.
6. Întreținere
Regular maintenance of your Scotsman Ice Machine, including inspection of components like the dump valve solenoid, is crucial for longevity and efficient operation. While the solenoid itself typically requires minimal direct maintenance, consider the following:
- Inspecție vizuală: Periodically inspect the solenoid and its connections for signs of wear, corrosion, leaks, or damage.
- curatenie: Ensure the area around the dump valve is free from debris or mineral buildup that could impede its function.
- Verificarea funcționalității: During routine ice machine maintenance, observe the dump valve's opening and closing action to confirm it operates smoothly and completely.
Dacă observați probleme, consultați un tehnician calificat pentru diagnosticare și o posibilă înlocuire.
7. Depanare
If your ice machine is experiencing drainage issues, the dump valve solenoid may be a contributing factor. Common symptoms and potential causes include:
- Fără drenaj / Drenaj lent:
- Solenoid coil failure (no power or open circuit).
- Valve mechanism stuck due to mineral buildup or debris.
- Clogged drain line downstream of the valve.
- Continuous Drainage / Leaking:
- Valve not closing completely (debris, worn seal).
- Solenoid continuously energized (electrical issue).
For detailed troubleshooting, refer to the service manual for your specific Scotsman Ice Machine model or contact a certified service technician.
8. Specificații
| Caietul de sarcini | Detaliu |
|---|---|
| Marca | scoţian |
| Numărul de model | 11-0564-01 |
| Numărul piesei | 11-0564-01 |
| Greutatea articolului | 4.8 uncii |
| Dimensiuni produs (L x l x H) | 4 x 4 x 6 inci |
| Dimensiunea conexiunii de intrare | 4 inchi |
| Tip de conectare la intrare | Țeavă de fier feminină |
| Dimensiunea conexiunii prizei | 4 inchi |
| Tip conexiune priză | NPT |
| Numărul de porturi | 2 |
| Specificație Met | OEM |
| UPC | 058121658129 |
9. Garanție și asistență
As a genuine OEM part, the Scotsman 11-0564-01 Dump Valve Solenoid is typically covered by the manufacturer's standard warranty for replacement parts. For specific warranty details, please refer to the documentation provided with your original Scotsman Ice Machine or contact Scotsman customer support directly. For technical assistance or service, it is recommended to contact an authorized Scotsman service provider.