This manual provides essential information for the safe and efficient operation of your Bio Green FY 45 Greenhouse Gas Heater. Please read these instructions thoroughly before installation and use. Proper installation, operation, and maintenance are crucial for your safety and the longevity of the product.

2. Informații de siguranță

WARNING: Failure to follow these safety instructions could result in fire, explosion, property damage, personal injury, or death.

  • Always ensure adequate ventilation when operating the heater in an enclosed space like a greenhouse.
  • Nu depozitați și nu folosiți benzină sau alți vapori și lichide inflamabile în apropierea acestui aparat sau a oricărui alt aparat.
  • Check all gas connections for leaks using a soapy water solution before initial use and after any gas cylinder change. Never use an open flame to check for leaks.
  • Keep combustible materials at a safe distance from the heater. Refer to local regulations for specific clearances.
  • Ensure the heater is installed on a stable, non-combustible surface or securely mounted to a wall.
  • Never leave the operating heater unattended.
  • Țineți copiii și animalele de companie departe de încălzitor.
  • Only use the type of gas and pressure regulator specified for this appliance.
  • If you smell gas, immediately shut off the gas supply, ventilate the area, and do not operate any electrical switches or appliances. Contact a qualified technician.

3. Conținutul pachetului

Vă rugăm să verificați dacă toate componentele sunt prezente și intacte:

  • Bio Green FY 45 Greenhouse Gas Heater unit
  • Manual de instructiuni
  • Mounting hardware (if applicable for wall mounting)

Note: Gas hose and pressure regulator are typically sold separately and must be compatible with your gas supply and local regulations.

4. Specificații

CaracteristicăCaietul de sarcini
MarcaBio Green
Numărul de modelAF 45
CuloareMaro
MaterialOţel inoxidabil
Greutatea articolului5 kilograme
Factor de formăPiedestal
Utilizare în interior/exteriorIndoor (Greenhouse)
Sursa de alimentareAlimentat cu gaz
Metoda de încălzireRadiant
Dimensiunile produsului26D x 36W x 41H centimetri
Utilizare recomandatăGreenhouse Heating
Tip de montareMontare pe perete
Tip de camerăSeră
Putere de ieșire4500 W

5. Configurare

5.1 Plasarea

Place the heater on a firm, level, non-combustible surface. Ensure there is sufficient clearance from walls, plants, and any flammable materials. If wall-mounting, use appropriate hardware and ensure the wall can support the heater's weight and is non-combustible.

Bio Green FY 45 Greenhouse Gas Heater mounted on a white brick wall

Image: The Bio Green FY 45 heater shown mounted on a wall, demonstrating a possible installation method.

5.2 Ventilație

Adequate ventilation is critical for gas heaters to prevent the accumulation of harmful gases. Ensure your greenhouse has proper ventilation openings or systems to allow for fresh air intake and exhaust of combustion byproducts.

5.3 Conexiune la gaz

  1. Ensure the gas cylinder valve is closed before connecting.
  2. Connect a suitable gas hose and pressure regulator (not included) to your gas cylinder (e.g., propane or butane). Ensure the regulator is compatible with the gas type and pressure requirements of the FY 45 heater.
  3. Connect the other end of the gas hose to the inlet connection on the heater. Ensure all connections are tight and secure.
  4. Once connected, slowly open the gas cylinder valve.
  5. Apply a soapy water solution to all gas connections. If bubbles appear, there is a leak. Immediately close the gas valve and tighten the connection. Re-test until no bubbles are present.
Close-up of the gas connection point on the Bio Green FY 45 heater with an orange gas hose attached

Imagine: O imagine detaliată view of the gas inlet and control knob on the heater, with an orange gas hose connected.

6. Instrucțiuni de utilizare

6.1 Aprindere

  1. Ensure the gas supply is open and the heater is properly ventilated.
  2. Turn the control knob to the pilot light setting (usually marked with a small flame symbol).
  3. Press and hold the control knob down while simultaneously pressing the igniter button (often red). You should hear a click and see a small pilot flame ignite.
  4. Continue to hold the control knob down for approximately 10-20 seconds after the pilot flame ignites to allow the thermocouple to heat up and hold the pilot flame.
  5. Eliberați butonul de control. Dacă flacăra pilot se stinge, repetați pașii 2-4.
  6. Once the pilot flame is stable, turn the control knob to the desired heat setting. The main burner will ignite.
Close-up of the glowing burner inside the Bio Green FY 45 heater

Imagine: Un prim-plan view of the radiant burner element, showing it in operation with a warm glow.

6.2 Controlul temperaturii

The control knob allows you to adjust the heat output. Turn the knob to increase or decrease the flame size and thus the heat generated. Monitor the greenhouse temperature to achieve the desired environment for your plants.

6.3 Închidere

  1. Turn the control knob to the 'OFF' position. The main burner will extinguish.
  2. Închideți supapa de pe butelia de gaz.
  3. Allow the heater to cool down completely before handling or moving.

7. Întreținere

7.1 Verificări regulate

  • Periodically inspect the gas hose for cracks, cuts, or wear. Replace immediately if any damage is found.
  • Verificați etanșeitatea tuturor racordurilor de gaz.
  • Ensure the air inlets and outlets are free from obstructions.

7.2 Curățare

  • Ensure the heater is completely cool and the gas supply is off before cleaning.
  • Wipe the exterior of the heater with a damp pânză. Nu utilizați agenți de curățare abrazivi sau solvenți.
  • Gently clean any dust or debris from the burner area and ventilation grilles using a soft brush or vacuum cleaner.

7.3 Depozitare

When not in use for extended periods, disconnect the gas cylinder and store the heater in a dry, protected area, away from direct sunlight and extreme temperatures.

8. Depanare

ProblemăCauza posibilaSoluţie
Heater does not igniteNo gas supply, faulty igniter, pilot light issueCheck gas cylinder, ensure valve is open. Check igniter spark. Hold pilot knob longer.
Pilot light goes outThermocouple not heated, draft, low gas pressureHold pilot knob longer. Check for drafts. Ensure adequate gas supply.
Putere termică scăzutăLow gas pressure, incorrect settingCheck gas cylinder level. Adjust control knob to higher setting.
Miros de gazScurgere de gazeImmediately shut off gas supply. Ventilate area. Check all connections with soapy water. Do not operate. Contact qualified technician if leak persists.

Dacă întâmpinați probleme care nu sunt enumerate aici sau dacă soluțiile nu rezolvă problema, vă rugăm să contactați serviciul de asistență pentru clienți.

9. Garanție și asistență

For warranty information or technical support, please refer to the documentation provided at the time of purchase or visit the official Bio Green webPăstrați bonul fiscal ca dovadă a achiziției.

Documente conexe - AF 45

Preview Încălzitor de seră Bio Green Frosty 2500 / 4500: Manual de instalare și utilizare
Manual complet de instalare și utilizare pentru încălzitoarele de seră pe gaz Bio Green Frosty 2500 și Frosty 4500. Acoperă siguranța, configurarea, funcționarea, datele tehnice și depanarea.
Preview Bio Green PALMA TWIN Air Circulation Heater: Installation and Operating Instructions
Comprehensive installation and operating instructions for the Bio Green PALMA TWIN air circulation heater (PAL T-US), covering safety, usage modes, technical specifications, maintenance, and warranty information.
Preview Bio Green Phoenix 2.8 Air Circulation Heater: Installation and Operation Manual
Comprehensive guide for installing and operating the Bio Green Phoenix 2.8 air circulation heater, including technical data, safety instructions, and usage recommendations for greenhouses and winter gardens.
Preview Bio Green Palma 2.0 Air Circulation Heater: Installation & Operating Manual
Comprehensive guide for installing and operating the Bio Green Palma 2.0 and Palma 2.0 RAW air circulation heaters, including technical data, safety instructions, and maintenance.
Preview Bio Green Palma 2.0 Installation and Operating Instructions
Comprehensive guide for the Bio Green Palma 2.0 air circulator heater, covering installation, operation, and safety precautions. Includes details for both manual and digital thermostat models.