1. Produs terminatview
The Fluke 325 True-RMS Clamp Meter is a versatile and reliable tool designed for general electrical troubleshooting. It accurately measures AC current, AC and DC voltage, resistance, frequency, temperature, and capacitance. Its compact design and robust construction make it suitable for various industrial and residential applications.

Imagine: față view of the Fluke 325 True-RMS Clamp Meter, displaying its digital screen and function dial.
Caracteristici cheie:
- Digital clamp meter measures AC current up to 400 A, AC and DC voltage up to 600 V, and resistance up to 4 kΩ.
- True-RMS sensing provides accurate readings for linear and non-linear loads.
- Jaw opening of 30 mm allows current measurement without interrupting the circuit.
- Audible continuity sensor for quick circuit checks.
- Meets IEC safety standard 61010-1, rated for CAT IV installations to 300 V and CAT III installations to 600 V.
- Includes frequency, temperature, and capacitance measurement capabilities.
2. Informații importante privind siguranța
Always read and understand the safety instructions before using the Fluke 325 Clamp Meter. Failure to follow safety warnings can result in serious injury or death.
- Do not use the meter if it is damaged or operating abnormally.
- Verify the meter's operation on a known voltage source before use.
- Aveți grijă când lucrați cu voltages above 30 V AC RMS, 42 V AC peak, or 60 V DC. These voltagreprezintă un pericol de șoc.
- Folosiți întotdeauna terminalele, funcția și intervalul adecvate pentru măsurători.
- Țineți degetele în spatele apărătorilor de degete de pe sondele de testare.
- The Fluke 325 is rated for CAT IV 300 V and CAT III 600 V. Ensure the meter's rating is appropriate for the environment where it will be used.
3. Noțiuni introductive: Configurare
Instalarea bateriei
The Fluke 325 requires two AA batteries (included). To install or replace batteries:
- Asigurați-vă că aparatul de măsură este oprit.
- Localizați compartimentul bateriilor pe spatele contorului.
- Folosiți o șurubelniță pentru a deschide capacul compartimentului bateriei.
- Insert two AA batteries, observing correct polarity.
- Puneți la loc capacul compartimentului bateriei și fixați-l cu șurubul.
Conectarea cablurilor de testare
Pentru voltage, resistance, continuity, frequency, temperature, and capacitance measurements, connect the test leads to the appropriate input jacks:
- Introduceți sonda neagră de testare în mufa COM (comună).
- Insert the red test lead into the VΩHz jack for most measurements.

Image: The Fluke 325 Clamp Meter displayed with its test leads, temperature probe, and soft carrying case.
4. Operating Your Fluke 325
Selector de funcții
The large yellow rotary dial on the front of the meter is used to select the desired measurement function. Turn the dial to the appropriate setting for your task.
Măsurarea curentului AC/DC (Clamp)
Pentru a măsura curentul alternativ sau continuu:
- Turn the function dial to the ∼A (AC current) or =A (DC current) position.
- Deschide clamp jaws by pressing the lever.
- Place the jaws around a single conductor. Ensure the jaws are fully closed.
- Citiți valoarea curentă de pe afișaj.

Image: A gloved hand using the Fluke 325 Clamp Meter to measure current on a wire within an electrical panel, showing a reading of 38.7 A.
VoltagMăsurare (AC/DC)
Pentru a măsura volul AC sau DCtage:
- Connect the test leads as described in the 'Connecting Test Leads' section.
- Turn the function dial to the ∼V (AC voltage) or =V (DC voltage) poziţia.
- Atingeți sondele de testare punctele circuitului unde volumultage este de măsurat.
- Citiți voltage valoarea pe display.
Rezistență și continuitate
Pentru a măsura rezistența sau a verifica continuitatea:
- Conectați sondele de testare.
- Turn the function dial to the Ω (resistance/continuity) position.
- Touch the test probes across the component or circuit path.
- For resistance, read the value on the display. For continuity, the meter will beep if a continuous path is detected.
Frequency, Temperature, and Capacitance
The Fluke 325 also offers specialized measurements:
- Frecvența (Hz): Select the Hz function to measure the frequency of AC signals.
- Temperature (°C/°F): Use the included temperature probe and select the temperature function to measure temperature.
- Capacitate: Select the capacitance function to measure the capacitance of components.
True-RMS Accuracy
The True-RMS feature ensures accurate measurements of AC voltage and current, even when waveforms are distorted or non-sinusoidal. This is crucial for modern electrical systems with non-linear loads.
Afișaj cu fundal luminos
The Fluke 325 features a backlit display for improved visibility in dimly lit environments. Press the backlight button to activate or deactivate the backlight.
Video: Official Fluke overview of the 32X series True-RMS Clamp Meters, highlighting features like compact design, safety ratings, True-RMS accuracy, backlit display, temperature measurements, and DC current measurement (for 325 model).
5. Întreținere și îngrijire
Curatenie
To clean the meter, wipe it with a damp o lavetă și un detergent blând. Nu utilizați abrazive sau solvenți. Asigurați-vă că aparatul de măsură este complet uscat înainte de utilizare.
Înlocuirea bateriei
When the battery indicator appears on the display, replace the batteries as described in the 'Battery Installation' section.
Depozitare
Depozitați contorul într-un loc răcoros și uscat, ferit de lumina directă a soarelui și de temperaturi extreme. Dacă îl depozitați pentru perioade lungi de timp, scoateți bateriile pentru a preveni scurgerile.
6. Depanarea problemelor comune
- Fără afișaj/alimentare: Verificați instalarea bateriilor și asigurați-vă că bateriile nu sunt descărcate.
- Citiri inexacte: Verify correct function and range selection. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
- Continuity Beeper Not Working: Check if the function dial is set to continuity and test leads are making good contact.
- „OL” pe afișaj: This indicates an overload or out-of-range measurement. Select a higher range or ensure the measured value is within the meter's specifications.
7. Specificatii tehnice
| Caietul de sarcini | Valoare |
|---|---|
| Numărul de model | FLUKE-325 |
| Curent alternativ | 400 A |
| Curent DC | 400 A |
| AC Voltage | 600 V |
| DC Voltage | 600 V |
| Rezistenţă | 4 kΩ |
| Frecvenţă | Da |
| Temperatură | Da |
| Capacitate | Da |
| Evaluare de siguranță | CAT IV 300 V, CAT III 600 V |
| Sursa de alimentare | 2 baterii AA |
| Greutatea articolului | 295 de grame (10.41 uncii) |
| Dimensiuni | 9.45 x 11 x 3.15 inci |
8. Garanție și asistență pentru clienți
Fluke products are known for their quality and reliability. For specific warranty details and terms, please refer to the warranty card included with your product or visit the official Fluke website. For technical assistance, troubleshooting, or service, please contact Fluke customer support directly.
Resurse online: www.fluke.com