Armstrong R40403-003

Manual de instrucțiuni pentru placa de circuit de control al suflantei cuptorului Armstrong R40403-003

Model: R40403-003

Produs terminatview

The Armstrong R40403-003 blower control circuit board is designed to replace previous versions R40403-001, R40403-002, and ST9120A, B, or C blower controls. This board manages a 2-speed indoor blower motor and a single-speed inducer motor. It processes inputs from the thermostat (W, Y, and G terminals), pressure switch, and high-temperature limit switches. The control also features user-selectable blower delays via DIP switch settings. A 5-amp replaceable automotive-type fuse protects the 24-volt circuit.

Armstrong R40403-003 Blower Control Circuit Board

Image 1: The Armstrong R40403-003 Blower Control Circuit Board. This image displays the front view of the circuit board, showing various electronic components, relays, terminals, and DIP switches.

Informații de siguranță

Always disconnect power to the furnace at the main breaker before attempting any installation, maintenance, or troubleshooting. Failure to do so can result in electrical shock, personal injury, or death. Installation should only be performed by qualified personnel. Ensure all wiring connections comply with local and national electrical codes.

  • Deconectare de la curent: Turn off power at the circuit breaker before handling the board.
  • Descărcare statică: Handle the circuit board by its edges to avoid damage from static electricity.
  • Protectie cu siguranta: The 24-volt circuit is protected by a 5-amp automotive-type fuse. Replace only with a fuse of the same rating.

Configurare și instalare

This section provides general guidelines for replacing the Armstrong R40403-003 blower control board. Refer to your furnace's specific wiring diagram for detailed instructions.

  1. Oprire: Ensure all power to the furnace unit is disconnected at the main electrical breaker. Verify with a voltage tester.
  2. Accesați vechea tablă: Locate and access the existing blower control board within your furnace.
  3. Cablare document: Before disconnecting any wires, take clear photographs of all connections to the old board. Label each wire if necessary.
  4. Deconectați firele: Deconectați cu grijă toate firele de la vechea placă de control.
  5. Îndepărtați placa veche: Deșurubați sau desprindeți placa veche de pe suportul său.
  6. Montați o nouă placă: Secure the new Armstrong R40403-003 board in the same location using the existing mounting hardware.
  7. Conectează firele: Reconnect all wires to the new board, matching them precisely to the documented connections from the old board. Pay close attention to the transformer leads (C and X terminals). The X lead from the old board typically connects to the XFRMR terminal on the new board.
  8. Setări DIP switch: Adjust the DIP switches on the new board to match the settings of your previous board or according to your furnace's specifications for blower delays.
  9. Inspectați conexiunile: Verificați de două ori toate conexiunile cablurilor pentru siguranță și corectitudine.
  10. Restabiliți puterea: Once all connections are verified, restore power to the furnace at the main breaker.
  11. Funcționare de testare: Initiate a heating or cooling cycle to confirm proper operation of the furnace and blower.
Armstrong R40403-003 Blower Control Circuit Board Packaging

Image 2: The Armstrong R40403-003 Blower Control Circuit Board in its packaging. This image shows the brown cardboard box with a product label indicating "BLOWER CONTROL" and the model number R40403-003.

Principii de funcționare

The R40403-003 board functions as the central control for the furnace's blower and inducer motors. It receives signals from the thermostat to initiate heating or cooling cycles. The board then activates the appropriate motors and monitors safety limits such as the pressure switch and high-temperature limit switches to ensure safe operation. User-selectable DIP switch settings allow for customization of blower delays, which control how long the blower runs after the heating or cooling call ends, helping to maximize system efficiency and comfort.

Blower Delay Settings

The board features DIP switches to adjust blower delays. Consult your furnace manual or the wiring diagram provided with the board for specific delay settings and their corresponding switch configurations. Typical settings include delays for fan off after heating, and fan on/off for cooling cycles.

Întreţinere

The Armstrong R40403-003 blower control board is designed for reliable operation and generally requires minimal maintenance. However, periodic checks of the furnace system are recommended.

  • Verificarea siguranței: Periodically inspect the 5-amp automotive-type fuse on the board. If the fuse is blown, replace it only with a fuse of the exact same rating (5 amp). A blown fuse often indicates an underlying electrical issue that should be investigated.
  • Conexiuni cablare: Annually, or during routine furnace maintenance, inspect all wiring connections to the board to ensure they are secure and free from corrosion.
  • Curăţenie: Keep the area around the circuit board clean and free from dust and debris, which can impede proper function or lead to overheating.

Depanare

This section provides basic troubleshooting steps for common issues related to the blower control board. For complex problems, consult a qualified HVAC technician.

ProblemăCauza posibilaSoluţie
Furnace not starting / No power to boardBlown fuse on board, tripped circuit breaker, loose wiring connection.Check and replace 5-amp fuse. Reset circuit breaker. Inspect and secure all power connections.
Motorul suflantei nu funcționeazăIncorrect thermostat input, faulty pressure switch, high-limit switch tripped, motor issue, board malfunction.Verify thermostat settings. Check pressure switch and high-limit switch for continuity. Consult HVAC technician for motor or board diagnosis.
Suflanta functioneaza continuuThermostat fan setting "ON", stuck relay on board, incorrect DIP switch setting.Set thermostat fan to "AUTO". Check DIP switch settings for blower delays. If issue persists, board may need replacement.
Inducer motor not runningFaulty inducer motor, pressure switch issue, board malfunction.Check inducer motor for power. Verify pressure switch operation. If necessary, consult a professional.

Specificații

Key technical specifications for the Armstrong R40403-003 Blower Control Circuit Board:

  • Număr de model: R40403-003
  • Replaces Models: R40403-001, R40403-002, 20054502, ST9120A, B, C
  • Operating Line Voltage: 85 până la 135 VAC, 50/60 Hz
  • Secondary Control Voltage: 18.0 până la 30.0 VAC, 50/60 Hz
  • Maximum Blower Loading: 15FLA, 30LRA @ 120 VAC; 7.5FLA, 15LRA @ 240 VAC
  • Maximum Inducer Loading: 3FLA, 10LRA @ 120 VAC; 1.5FLA, 5LRA @ 240 VAC
  • Protectie cu siguranta: 5 Amp replaceable automotive type fuse (24-volt circuit)
  • Dimensiuni: Aproximativ 7.8 x 6.3 x 3 inci
  • Greutate: Aproximativ 0.16 uncii
  • Producător: Armstrong

Garanție și suport

Specific warranty information for the Armstrong R40403-003 Blower Control Circuit Board is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the product packaging or contact Armstrong customer support directly. For technical assistance or professional installation, it is recommended to consult a certified HVAC technician.

You may visit the official Armstrong website or contact their customer service for further support.

  • Producător: Armstrong
  • Website: www.armstrongair.com (General Armstrong HVAC site, as no specific product support link is provided)

Documente conexe - R40403-003

Preview Lista pieselor și ghidul componentelor L83BR1D84/95E16
Acest document oferă o listă completă de piese pentru modelul L83BR1D84/95E16, detaliind denumirile componentelor, numerele de piese și descrierile pentru a ajuta la identificare și înlocuire.
Preview Sfaturi tehnice și buletine de service Armstrong HVAC
Colecție de sfaturi tehnice și buletine de service pentru sistemele de aer condiționat Armstrong, care acoperă îmbunătățiri ale controlului aprinderii, funcționarea continuă a ventilatorului, detalii despre compresor, dimensionarea filtrelor, cablare, borduri de acoperiș și depanare pentru unitățile HVAC PGE, PHP, PCE și SHP.
Preview Armstrong GFCI Receptacle Installation and Testing Guide
A comprehensive guide for installing and testing Armstrong GFCI receptacles, including wiring instructions, troubleshooting tips, and warranty information.
Preview Instalare tavan fals Armstrong pesteviewUn ghid pas cu pas
Învață cum să instalezi un tavan fals Armstrong cu ajutorul acestei instrucțiuni concise.viewAcoperă instalarea de profile decorative pentru pereți, grinzi principale, profile T transversale și panouri de tavan pentru uz rezidențial. Dispune de accesorii QuickHang™.
Preview Instrucțiuni de instalare și utilizare a pompei de circulație de înaltă eficiență Armstrong seria E.2
Instrucțiuni complete de instalare și operare pentru pompa de circulație de înaltă eficiență Armstrong seria E.2, care acoperă limitele de funcționare, cablajul electric, procedurile de pornire, întreținerea, înlocuirea pompei și înlocuirea etanșării mecanice.
Preview Ghid de instalare a finisajelor ascunse WoodWorks® | Armstrong
Ghid complet de instalare pentru sistemul de finisaje ascunse WoodWorks® de la Armstrong. Aflați cum să instalați corect acest finisaj arhitectural pentru tavan, atât pentru panourile furniruite ascunse, cât și pentru cele liniare WoodWorks®.