Johnson Controls V-9012-1

Manual de instrucțiuni pentru releul electrovalvei Johnson Controls V-9012-1

Model: V-9012-1

1. Introducere

This manual provides detailed instructions for the installation, operation, and maintenance of the Johnson Controls V-9012-1 E/P Solenoid Relay. This device is designed to convert an electrical signal into a pneumatic output, controlling air pressure based on a 12 VDC input. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Informații de siguranță

Adherence to safety precautions is crucial for preventing injury and damage to the equipment. Always follow local codes and regulations.

  • Personal calificat: Installation and servicing must be performed by qualified and experienced personnel only.
  • Siguranta electrica: Disconnect all power to the device and associated equipment before performing any wiring or maintenance. Ensure proper grounding.
  • Pneumatic Safety: Depressurize all pneumatic lines before making or breaking connections. Wear appropriate personal protective equipment.
  • Conditii de mediu: Do not expose the device to conditions outside its specified operating range (temperature, humidity, pressure).

3. Produs terminatview

The Johnson Controls V-9012-1 is an Electro-Pneumatic (E/P) Solenoid Relay that converts a 12 VDC electrical input into a pneumatic control signal. It is commonly used in industrial applications to manage air pressure for actuators or other pneumatic devices.

3.1. Caracteristici cheie

  • 12 VDC Input for electrical control.
  • Solenoid Valve functionality for precise pneumatic regulation.
  • Relay operation for switching pneumatic states.
  • Maximum input current of 50 mA.

3.2. Components and Labeling

Refer to the image below for a visual representation of the V-9012-1 Solenoid Valve Relay and its key labeled components.

Johnson Controls V-9012-1 E/P Solenoid Relay with labels

Figure 1: Johnson Controls V-9012-1 E/P Solenoid Relay

The image displays the Johnson Controls V-9012-1 E/P Solenoid Relay. Key labels visible on the device include:

  • V-9012-1 E/P SOLENOID RELAY: Identifies the model and type of device.
  • PAT 4,770,200 and PAT 4,804,009: Patent numbers associated with the product.
  • BO TERM. 1 (RED): Indicates the first electrical terminal, typically for the positive 12 VDC input.
  • 12 V.D.C. INPUT (50 mA. MAX.): Specifies the required input voltage și curentul maxim.
  • BO TERM. 2 (BLK) RESISTOR: Indicates the second electrical terminal, typically for the negative connection, and notes the presence of a resistor.
  • LIVRA: The inlet port for the pneumatic supply pressure.
  • ACTUATOR: The outlet port for the controlled pneumatic pressure to the actuator.
  • +12 V.D.C. PRESS.: Indicates that a +12 VDC input results in a 'PRESS' (pressure) state.
  • 0 V.D.C. HOLD: Indicates that 0 VDC input results in a 'HOLD' state.
  • -12 V.D.C. EXHAUST: Indicates that a -12 VDC input results in an 'EXHAUST' state.

4. Configurare și instalare

Proper installation is critical for the correct functioning of the V-9012-1 Solenoid Relay.

4.1. Verificări înainte de instalare

  • Verify that the power supply matches the device's requirements (12 VDC).
  • Inspect the device for any visible damage from shipping.
  • Asigurați-vă că sunt disponibile toate uneltele și accesoriile necesare.

4.2. Montare

Mount the solenoid relay securely in a location that is free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections.

4.3. Instrucțiuni de cablare

Urmați acești pași pentru conexiunile electrice:

  1. Ensure the power source is completely disconnected.
  2. Connect the positive (+) 12 VDC power supply wire to BO TERM. 1 (RED).
  3. Connect the negative (-) 12 VDC power supply wire to BO TERM. 2 (BLK). Note that this terminal includes a resistor.
  4. Verificați că toate conexiunile sunt sigure și izolate corespunzător.

4.4. Pneumatic Connections

Follow these steps for pneumatic connections:

  1. Connect the main pneumatic supply line to the port labeled LIVRA. Ensure the supply pressure is within the device's specified operating range.
  2. Connect the line leading to the pneumatic actuator or controlled device to the port labeled ACTIONATOR.
  3. Check all pneumatic connections for leaks after pressurizing the system.

5. Funcționare

The V-9012-1 Solenoid Relay operates based on the applied electrical input voltage, controlling the pneumatic output to the actuator.

  • +12 VDC Input: When a positive 12 VDC is applied to the input terminals, the relay will enter a 'PRESS' state, allowing supply pressure to flow to the actuator.
  • 0 VDC Input: When 0 VDC (no voltage) is applied, the relay will enter a 'HOLD' state, maintaining the current pneumatic output.
  • -12 VDC Input: When a negative 12 VDC is applied, the relay will enter an 'EXHAUST' state, releasing pressure from the actuator.

Ensure that the control system provides the correct voltage signals for the desired pneumatic response.

6. Întreținere

The Johnson Controls V-9012-1 Solenoid Relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and optimal performance.

  • Inspecție de rutină: Periodically inspect the device for any signs of wear, corrosion, or damage to the housing, wiring, and pneumatic connections.
  • curatenie: Keep the exterior of the device clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Integritatea conexiunii: Verify that all electrical and pneumatic connections remain tight and secure.
  • Serviciu profesional: For internal issues or complex repairs, contact a qualified service technician or Johnson Controls support. Do not attempt to disassemble the unit.

7. Depanare

This section provides solutions to common issues that may arise during the operation of the V-9012-1 Solenoid Relay.

ProblemăCauza posibilaSoluţie
Device does not respond to electrical input.Fără alimentare, volum incorecttage, loose wiring, internal fault.Check 12 VDC power supply. Verify wiring connections to Terminals 1 and 2. Ensure correct polarity. If problem persists, contact support.
Pneumatic output is incorrect or inconsistent.Insufficient supply pressure, clogged lines, leaks in pneumatic connections, internal valve issue.Check pneumatic supply pressure. Inspect lines for obstructions or leaks. Ensure correct electrical input for desired pneumatic state.
Dispozitivul se supraîncălzi.Excessive current, improper ventilation, continuous operation beyond duty cycle.Verify input current does not exceed 50 mA. Ensure adequate airflow around the device. Review application for duty cycle requirements.

8. Specificații

Technical specifications for the Johnson Controls V-9012-1 E/P Solenoid Relay:

ParametruValoare
Numărul de modelV-9012-1
FuncţieE/P Solenoid Relay
Vol. De intraretage12 VDC
Curent maxim de intrare50 mA
Pneumatic StatesPress (+12 VDC), Hold (0 VDC), Exhaust (-12 VDC)
ProducătorCONTROALE JOHNSON
Greutatea articolului6.4 uncii
Data primului disponibil5 iulie 2012

9. Garanție și asistență

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly through their official website or customer service channels. Keep your purchase receipt and product model number readily available when seeking support.

Documente conexe - V-9012-1

Preview Robinete cu colivie din bronz Johnson Controls: Ghid de produse de la 3/4 la 2 inch
Ghid tehnic complet pentru valvele cu colivie din bronz Johnson Controls (de la 3/4 la 2 inch), care detaliază caracteristicile, opțiunile de actuatoare pneumatice și electrice, specificațiile, funcționarea, instalarea și piesele de schimb pentru aplicații HVAC.
Preview Traductoare electropneumatice Johnson Controls seria EP-8000: Specificații tehnice, instalare și funcționare
Buletin tehnic detaliat pentru traductoarele electropneumatice Johnson Controls din seria EP-8000. Acoperă produsul pesteview, funcționare, dimensiuni, instalare, cablare, calibrare și specificații tehnice pentru aplicații de control industrial.
Preview Ghid de instalare pentru vanele de control din bronz din seria VG7000
Instrucțiuni complete de instalare și specificații tehnice pentru vanele de control din bronz Johnson Controls seria VG7000, concepute pentru reglarea apei și a aburului în sistemele HVAC. Include dimensiunile vanei, materialele și parametrii de funcționare.
Preview Catalog de piese de schimb pentru valve Johnson Controls
Catalog complet care detaliază piesele de schimb, inclusiv diafragme, kituri de arcuri, kituri de etanșare, kituri de recondiționare și alte componente pentru o gamă largă de valve pneumatice și electrice Johnson Controls.
Preview Ghid de instalare a dispozitivului de curent cu miez divizat Johnson Controls seria CSD
Ghid tehnic și de instalare pentru dispozitivele de curent cu miez separat Johnson Controls seria CSD (CSD-CF0J1-1, CSD-CA1G1-1) cu releu. Acoperă aplicații, cablare, calibrare, depanare și specificații pentru monitorizarea curentului industrial.
Preview Ghid de instalare a valvei de control compacte cu sferă (axială) VP1000
Ghid de instalare pentru valva de control Johnson Controls VP1000 Compact Globe (Axial), acoperind dimensiuni de la 1/2 inch la 1 1/4 inch (DN15-DN32). Oferă specificații tehnice, instrucțiuni de montare și informații despre întreținere.