Leviton 24W49

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug

Model 24W49 Instruction Manual

1. Produs terminatview

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is a robust wiring device designed for demanding industrial environments. This plug features a polarized, grounding, L6-15P configuration with 3 wires, rated for 250V AC and 15 Amps. It is constructed from EPTR rubber material in a yellow color, ensuring water-tight performance and resistance to various harsh conditions. The Wetguard line meets IP67 and NEMA ratings for water ingress protection, offering superior durability and reliability.

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug, Model 24W49

Figure 1: Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49)

2. Caracteristici cheie

  • Industrial Grade Construction: Built to withstand harsh industrial environments.
  • Watertight and Dust-tight: Meets IP67 and NEMA ratings for protection against water and dust ingress.
  • Material durabil: Made from EPTR rubber, resistant to water, acids, alkalis, lubricants, cleaners, and solvents.
  • Rezistenta la coroziune: Blades, contacts, terminal screws, and wiring clamps are electroless nickel-coated brass.
  • Cablare ușoară: Deep wire wells in the wiring module facilitate easier wiring.
  • Inspecție vizuală: Clear housing aids in inspecting for proper wire insertion and connection.
  • Conexiune sigură: Patented compression nut and strain relief system ensure integrity of both the watertight seal and electrical connection.
  • Configurare: L6-15P, 2-pole, 3-wire grounding.
  • Certificari: UL 498, CSA C22.2, NOM 057 approved.

3. Specificații

Caietul de sarciniValoare
Numărul de model24W49
Ampepoca15 Amps
Voltage250 volți
Format PlugType A (L6-15P)
Număr de fire3
Număr de poli2
ÎmpământareDa
MaterialEPTR Rubber
CuloareGalben
Cord Size Compatibility0.234 până la 0.687 inci
Dimensiunile produsului1.44 x 1.3 x 3.54 inci
Greutatea articolului3.2 uncii
CertificariUL 498, CSA C22.2, NOM 057

4. Informații de siguranță

Always follow local electrical codes and regulations when installing or servicing electrical devices. Improper installation or use can result in serious injury or death. Disconnect power at the circuit breaker or fuse box before working on any electrical wiring.

  • Ensure the power supply is OFF before installation or maintenance.
  • Folosiți echipament individual de protecție (EIP) adecvat, cum ar fi ochelari de protecție și mănuși izolante.
  • Verify correct wiring polarity and grounding connections.
  • Nu depășiți volumul specificattage și ampevaluările de performanță ale dispozitivului.
  • Keep the device clean and free from debris to maintain its watertight integrity.
  • If the device shows signs of damage, discontinue use and replace it immediately.

5. Instalare

This section outlines the general steps for wiring the Leviton Wetguard Locking Plug. For detailed wiring diagrams and specific instructions, refer to the packaging or consult a qualified electrician.

  1. Pregătiți cablul: Strip the outer jacket of the cable to the appropriate length, exposing the insulated conductors. Strip the insulation from each conductor.
  2. Dezasamblați ștecherul: Unscrew the compression nut and separate the plug housing components.
  3. Introduceți cablul: Feed the prepared cable through the compression nut and into the plug housing.
  4. Conexiuni prin cablu: Connect the conductors to the appropriate terminal screws. The clear housing allows for visual verification of proper wire insertion. Ensure all connections are tight and secure.
  5. Assemble the Plug: Reassemble the plug housing, ensuring the internal components are correctly aligned. Tighten the compression nut to create a watertight seal and engage the strain relief system.
  6. Verifica: Double-check all connections and ensure the plug is securely assembled before restoring power.

6. Funcționare

The Leviton Wetguard Locking Plug is designed for secure and reliable electrical connections in wet or dusty environments. To operate:

  1. Conectare: Align the blades of the locking plug with the corresponding slots on a compatible locking receptacle.
  2. Răsuciți pentru a bloca: Insert the plug fully and twist it clockwise until it locks into place. This action creates a secure mechanical and electrical connection, preventing accidental disconnection.
  3. Deconecta: To disconnect, twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.

The watertight design ensures safe operation even when exposed to moisture, provided the connection is properly mated and sealed.

7. Întreținere

Regular maintenance helps ensure the longevity and safe operation of your Leviton Wetguard Locking Plug.

  • Inspectie periodica: Visually inspect the plug and cable for any signs of wear, cuts, cracks, or discoloration. Check for loose connections or corrosion on the blades.
  • curatenie: Clean the exterior of the plug with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could damage the rubber material. Ensure the plug is dry before use.
  • Depozitare: When not in use, store the plug in a clean, dry environment to prevent damage and prolong its lifespan.
  • Integritatea sigiliului: Periodically check the integrity of the compression nut and strain relief system to ensure the watertight seal is maintained.

8. Depanare

If you encounter issues with your Leviton Wetguard Locking Plug, consider the following common troubleshooting steps:

  • Fără putere:
    • Check the power source (circuit breaker, fuse).
    • Ensure the plug is fully inserted and locked into the receptacle.
    • Inspectați cablul pentru a deteriorări.
  • Conexiune slabă:
    • Ensure the plug is twisted and locked securely.
    • If the internal wiring feels loose, disconnect power and re-check the terminal screw connections as per installation instructions.
  • Intrarea apei:
    • Verify that the compression nut is tightly secured.
    • Inspect the rubber housing for any cracks or damage that could compromise the seal.

If the problem persists after attempting these steps, contact Leviton customer support or a qualified electrician.

9. Related Product Information (Video)

Următorul videoclip oferă o imagine de ansamblu asupraview of the Leviton Wetguard line of watertight wiring devices, showcasing their features and applications in various industrial environments. While the video may feature different models within the Wetguard series, the core principles of durability, watertight sealing, and robust construction apply to the 24W49 locking plug.

Video: Pesteview of Leviton Wetguard Watertight Wiring Devices

10. Garanție și asistență

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the product packaging or visit the official Leviton website-ul.

For technical assistance, product inquiries, or support, please contact Leviton Customer Service:

  • Website: www.leviton.com
  • Serviciu clienți: Consultați website pentru informații de contact regionale.

Documente conexe - 24W49

Preview Ghid de selecție a întrerupătoarelor Leviton de calitate comercială și industrială
Un ghid complet de selecție de la Leviton care detaliază întrerupătoarele comerciale și industriale, inclusiv tipuri de întrerupătoare basculante, Decora Plus, Lev-lok, antimicrobiene și speciale, cu detalii despre aplicații și scheme de cablare.
Preview Ghid de instalare și testare a prizei GFCI Leviton
Un ghid complet despre cum se instalează și se testează o priză Leviton SmartLock Pro GFCI, inclusiv instrucțiuni de cablare, măsuri de siguranță și sfaturi de depanare.
Preview Leviton EV40P Seria EV 40 AMP Manual de instalare a încărcătorului cu priză
Manual de instalare pentru Leviton EV40P EV seria 40 AMP Încărcător de vehicule electrice cu priză. Include avertismente de siguranță, specificații, pași de instalare, proceduri de operare, utilizarea cardului RFID, mesaje de eroare, informații despre întreținere și garanție.
Preview Manual de instalare și utilizare a prizei Leviton GFCI cu porturi USB
Ghid complet pentru instalarea și operarea prizelor Leviton GFCI cu porturi USB, inclusiv instrucțiuni de cablare, avertismente de siguranță, proceduri de testare și informații despre garanție.
Preview Instalarea și testarea prizei inteligente GFCI Leviton: Un ghid complet
Instrucțiuni pas cu pas pentru instalarea și testarea prizelor Leviton Smart GFCI (modelele D2GF1, D2GF2). Aflați despre funcționalitatea GFCI, cablare, depanare și măsuri de siguranță.
Preview Leviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.