First Alert SCO5CN

First Alert SCO5CN Combination Smoke and Carbon Monoxide Detector User Manual

Model: SCO5CN | Brand: First Alert

1.view

The First Alert SCO5CN is a battery-operated combination smoke and carbon monoxide (CO) detector designed to provide comprehensive protection for your home. It integrates two essential sensors into a single unit: a photoelectric sensor for detecting smoke from smoldering fires and an advanced electrochemical sensor for detecting carbon monoxide. This dual functionality helps minimize false alarms while ensuring reliable detection of both threats. The unit features a loud 85-decibel siren and distinct alarm sounds and indicator lights to differentiate between smoke and carbon monoxide warnings.

First Alert SCO5CN Combination Smoke and Carbon Monoxide Detector

Figura 1: Față view of the First Alert SCO5CN detector, showing the test/silence button and indicator lights for CO, Power, and Smoke.

First Alert SCO5CN product features

Figure 2: Key features of the First Alert SCO5CN, highlighting 2-in-1 protection, photoelectric smoke sensor, UL standards compliance, and easy access battery door.

2. Configurare și instalare

The First Alert SCO5CN detector is designed for easy, battery-powered installation, requiring no electrical wiring. It comes with a mounting bracket and hardware for secure placement on a wall or ceiling.

2.1 Despachetarea și instalarea bateriei

  1. Carefully remove the detector and all components from the packaging.
  2. Locate the battery compartment on the side of the unit. Slide open the battery door.
  3. Insert the two AA batteries provided, ensuring correct polarity (+ and -). The unit will chirp once to indicate it has powered on.
  4. Închideți bine ușa bateriei.
First Alert SCO5CN with open battery compartment

Figure 3: The detector with its easy-access battery compartment open, showing the placement of two AA batteries.

2.2 Montarea detectorului

  1. Choose an appropriate location for installation. For optimal safety, install smoke alarms on every level of your home and in every bedroom. Carbon monoxide alarms should also be on every level and in sleeping areas.
  2. Attach the mounting bracket to the ceiling or wall using the provided screws and anchors. Ensure the bracket is firmly secured.
  3. Aliniați detectorul cu suportul de montare și rotiți în sensul acelor de ceasornic până când se blochează în poziție.
First Alert SCO5CN side view cu suport de montare

Figura 4: lateral view of the detector, illustrating how the mounting bracket attaches to the main unit.

Recommended placement of smoke and carbon monoxide alarms in a house

Figure 5: Diagram showing recommended placement of smoke and carbon monoxide alarms throughout a typical home, including bedrooms, hallways, living rooms, kitchens, basements, and garages.

2.3 de videoclipuri de instalare

Video 1: An official First Alert video demonstrating the features and installation process of the SCO5CN Smoke and Carbon Monoxide Detector. This video provides a visual guide to unpacking, battery insertion, and mounting the unit.

3. Instrucțiuni de utilizare

3.1 Butonul Test/Tăcere

The large 'Test/Silence' button on the front of the detector serves two primary functions:

First Alert SCO5CN with test/silence button highlighted

Figure 6: The detector with the 'Test/Silence' button clearly visible, indicating its dual functionality for testing and temporarily silencing alarms.

3.2 Alarm Signals and Indicator Lights

The detector uses distinct audible and visual signals to communicate different conditions:

4. Întreținere

Regular maintenance ensures the continued reliability of your First Alert SCO5CN detector.

4.1 Weekly Testing

Test your detector weekly by pressing and holding the 'Test/Silence' button until the alarm sounds. This confirms the unit is functioning correctly.

Person testing a smoke alarm on the ceiling

Figure 7: An individual performing a regular test on a ceiling-mounted smoke alarm.

4.2 Înlocuirea bateriei

When the detector emits a low battery chirp (one chirp per minute), replace both AA batteries immediately. Use the easy-access battery compartment for quick changes without removing the unit from its mounting bracket.

4.3 Curățare

Clean your detector at least once a month to remove dust and debris that could interfere with its operation. Use a soft brush attachment on your vacuum cleaner to gently clean the vents and openings. Do not paint the detector.

4.4 Înlocuire la sfârșitul duratei de viață

The detector has a limited lifespan. When the unit reaches its end-of-life (indicated by three chirps every minute), it must be replaced with a new one. This typically occurs after 10 years from the date of manufacture.

Person replacing a smoke alarm, indicating end-of-life replacement

Figure 8: An individual replacing a smoke alarm, emphasizing the importance of replacing units after their recommended lifespan, typically 10 years.

5. Depanare

ProblemăCauza posibilaSoluţie
Alarmă de neplăcereCooking smoke, steam, high humidity, dust.Press the Test/Silence button. Ventilate the area. Clean the detector.
Single Chirp every minuteBaterie descărcată.Înlocuiți imediat ambele baterii AA.
Three Chirps every minuteAvertizare de sfârșitul vieții.Înlocuiți întreaga unitate a detectorului.
Alarma sună continuuPresence of smoke or carbon monoxide.Evacuate the premises immediately and call emergency services.

6. Specificații

7. Garantie

The First Alert SCO5CN Combination Smoke and Carbon Monoxide Detector comes with a 5-year limited warranty. Please refer to the full warranty statement included with your product for detailed terms and conditions.

8. Suport

For technical assistance, troubleshooting, or warranty claims, please contact First Alert customer support. Refer to the product packaging or the First Alert website pentru cele mai recente informații de contact.

Documente conexe - SCO5CN

Preview First Alert ZCOMBO Combination Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert ZCOMBO Combination Smoke and Carbon Monoxide Alarm. Learn about installation, maintenance, testing, safety features, troubleshooting, and Z-Wave integration for enhanced home safety.
Preview Manual de utilizare al detectorului de fum și monoxid de carbon First Alert Onelink Wi-Fi AC10-500
Manual de utilizare complet pentru alarma de fum și monoxid de carbon First Alert Onelink AC10-500 Wi-Fi, care acoperă informații despre instalare, utilizare, întreținere, depanare și siguranță. Aflați despre caracteristicile, amplasarea, configurarea și procedurile de urgență ale alarmei.
Preview First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm Installation Guide
Installation guide for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (SMC0600NV), covering setup, placement, maintenance, and regulatory information.
Preview Ghid de pornire rapidă pentru alarma inteligentă wireless de fum și monoxid de carbon First Alert SC5
Ghid de pornire rapidă pentru alarma inteligentă wireless de fum și monoxid de carbon First Alert SC5 (model SMC0600NV). Include informații despre configurare, amplasare, funcții, întreținere, depanare și reglementări.
Preview Ghid de pornire rapidă pentru alarma inteligentă wireless de fum și monoxid de carbon First Alert SC5
Quick start guide for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (SMC0600NV), covering setup, installation, placement, maintenance, and troubleshooting.
Preview First Alert ZCOMBO Combination Smoke and Carbon Monoxide Alarm User Manual
This user manual provides detailed information on the First Alert ZCOMBO Combination Carbon Monoxide and Smoke Alarm, including installation, operation, safety precautions, maintenance, troubleshooting, and warranty details.