Aiphone LEF-5

Manual de utilizare interfon Aiphone LEF-5 Open Voice Selective Call Master

Introducere

Welcome to the Aiphone LEF-5 Open Voice Selective Call Master Intercom user manual. This document provides detailed instructions for the proper installation, operation, and maintenance of your intercom system. Please read this manual thoroughly before using the product to ensure optimal performance and safety.

Ce este în cutie?

Produs terminatview

The Aiphone LEF-5 is a master intercom unit designed for selective calling and communication within a building, capable of connecting with up to five other intercoms (door, sub-master, or master units). It features a door-release button for remote access control.

Aiphone LEF-5 Open Voice Selective Call Master Intercom unit

Imaginea 1: Faţă view of the Aiphone LEF-5 Master Intercom. The unit features a large speaker grille at the top. Below the speaker, there are five numbered call buttons (L1, L2, 3, 4, 5) with an 'OFF' indicator. A volume slider labeled 'VOL' is located on the left side of the control panel. An 'OCCUPIED' indicator is centrally located. On the right, there are three push buttons: 'LOCK' for door release, 'PRIV' for privacy, and 'TALK' for communication, with a 'CALL' indicator above the 'PRIV' button.

Înființat

Montare

The LEF-5 master intercom can be mounted on a desktop or wall. Use the provided mounting hardware to secure the unit in your desired location. Ensure the mounting surface is stable and allows for proper cable routing.

Conexiuni de cablare

The LEF-5 requires hardwired connections to other intercom units and a power supply. Each intercom in the system must be connected to an Aiphone RY-PA relay (sold separately) to enable door access control (e.g., electric strike) and integration with other devices like CCTV cameras or lights.

Alimentare electrică

The system is powered by a 12V power supply. An Aiphone PS-1225UL 12V power supply (sold separately) is recommended. Ensure the power supply is correctly connected according to the wiring instructions before operation.

Instrucțiuni de operare

Efectuarea unui apel

  1. Identify the desired intercom unit (door, sub-master, or master) you wish to call.
  2. Press the corresponding numbered button (L1, L2, 3, 4, or 5) on the LEF-5 unit. An LED indicator above the button will illuminate.
  3. Țineți apăsat butonul VORBI button to speak. Release the VORBI butonul pentru a asculta un răspuns.

Primirea unui apel

When a call is received from a sub-master intercom, a momentary chime will sound, and the corresponding LED indicator above the selectable call button will illuminate for approximately 20 seconds.

  1. To respond, press and hold the VORBI buton.
  2. Eliberați VORBI button to listen to the other party.

Comunicare bidirecțională

The LEF-5 operates on a push-to-talk, release-to-listen principle. Depressing the VORBI button allows you to transmit audio, and releasing it allows you to receive audio from the connected intercom.

Door Release Function

To remotely unlock a door connected to the system (requires Aiphone RY-PA relay and electric strike), press the BLOCARE button during a conversation with the door intercom.

Funcția de confidențialitate

Apăsați tasta privat (Privacy) button to prevent other intercom users within the system from overhearing your conversation with another intercom unit.

Listening Function

At any time, you can listen to audio transmissions from a specified door or sub-master intercom. Select the desired intercom using its numbered button, then activate the listening feature (specific activation method may vary, refer to system wiring for details).

Reglarea volumului

Adjust the audio volume using the VOL slider control located on the front panel.

Chime Off

To silence the master intercom's chime alerts for incoming calls, slide the 'OFF' switch to the 'OFF' position.

Întreţinere

To ensure the longevity and proper functioning of your Aiphone LEF-5 intercom, follow these simple maintenance guidelines:

Depanare

If you encounter issues with your Aiphone LEF-5 intercom, refer to the following common problems and solutions:

If these troubleshooting steps do not resolve the issue, please contact Aiphone customer support or a qualified technician.

Specificații

Numărul de modelLEF-5
Dimensiuni totale (înălțime x lățime x adâncime)8-1/8 x 7-1/2 x 2-3/16 inci
Communication Output (Reception)800mW la 20 ohmi
Communication Output (Transmission)500mW la 20 ohmi
Maximum Distance (Door/Sub to Master)650 ft (using 22 AWG wire)
1,600 ft (using 18 AWG wire)
Door Strike ConnectionRequires Aiphone RY-PA relay (sold separately)
Cerințe de putereAiphone PS-1225UL 12V power supply (sold separately)

Garanție și suport

For information regarding warranty coverage, technical support, or service, please refer to the official Aiphone website or contact Aiphone customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Aiphone North American Headquarters: Bellevue, WA

Documente conexe - LEF-5

Preview Sistem de interfon cu difuzor Aiphone LEF-LD: Instrucțiuni și cablare
Instrucțiuni detaliate și scheme de cablare pentru sistemul de interfon cu difuzor pentru distanțe lungi Aiphone LEF-LD, acoperind modelele LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD, LEF-3C-LD, LEF-5C-LD și LEF-10C-LD.
Preview Aiphone IC-1AD(U) Chime Tone Intercom System: Installation and Operation Guide
Comprehensive guide for the Aiphone IC-1AD(U) 1-door, 1-room chime tone intercom system, covering features, specifications, installation, wiring, operation, and warranty.
Preview Ghid de utilizare a stației pentru chiriași Aiphone GT-1C
Ghid complet de utilizare pentru stația telefonică Aiphone GT-1C. Aflați despre sursa de alimentare, ecranul LCD, difuzorul, microfonul și funcțiile butoanelor precum Deschidere ușă, Opțiune, Gardă, Vorbire și Oprire, împreună cu comenzile laterale pentru luminozitate, volum și zoom.
Preview Ghid de utilizare a stației principale Aiphone seria IX
Un ghid complet de utilizare pentru stația principală Aiphone seria IX, care detaliază funcțiile de bază, operațiunile butoanelor și indicatorii de stare.
Preview Aiphone LEM-1DLC Master Station Installation and Operation Guide
Detailed installation and operation guide for the Aiphone LEM-1DLC master station, designed for multiple master use with occupied lamp functionality, including wiring diagrams and specifications.
Preview Adaptor Aiphone JOW-2D pentru două uși, pentru sistemul de interfon video din seria JO - Ghid de instalare
Instrucțiuni și specificații detaliate pentru adaptorul Aiphone JOW-2D, care permite conectarea a două stații de ușă pentru sistemul de interfon video din seria JO. Aflați despre cablare, alimentare și caracteristici operaționale pentru instalațiile de interfon.