ANENG AOS03

ANENG AOS03 3-in-1 Oscilloscope Multimeter User Manual

Model: AOS03

1. Introducere

The ANENG AOS03 is a versatile 3-in-1 handheld device that integrates the functions of an oscilloscope, a multimeter, and a signal generator. Designed with a dual injection molding process, it features a compact size, convenient portability, and flexible operation. The device is equipped with a 3.5-inch IPS full-view color display, providing clear readings in various lighting conditions. With its superior performance and powerful functionality, the AOS03 is suitable for a wide range of electrical measurement and testing scenarios.

ANENG AOS03 3-in-1 Oscilloscope Multimeter Signal Generator
Figure 1.1: ANENG AOS03 3-in-1 Oscilloscope Multimeter with its core functions highlighted.
ANENG AOS03 Function 3 in 1 display
Figure 1.2: The AOS03 displaying its three primary functions: oscilloscope, multimeter, and signal generator output.

2. Conținutul pachetului

Before using the device, please verify that all items are present in the package:

ANENG AOS03 Accessories List
Figure 2.1: Complete accessories list for the ANENG AOS03.
  1. 3-in-1 Oscilloscope Multimeter (Main Unit)
  2. Manual de utilizare (x2)
  3. Geanta de depozitare
  4. Cutie de ambalare
  5. Extra Tip Pen
  6. Oscilloscope Pen
  7. Positioning Sleeve (x2)
  8. Tag Inel (x8)
  9. Cablu de date USB
  10. Șurubelniță de compensare a sondei
  11. Alligator Clip Ground Lead

3. Aspectul dispozitivului și comenzile

Familiarize yourself with the various parts and controls of your ANENG AOS03 device:

ANENG AOS03 Labeled Diagram with Dimensions
Figure 3.1: Detailed diagram of the ANENG AOS03 with labeled components and dimensions.
  1. Dual channel input
  2. 3.5-Inch VA reverse color screen
  3. USB charging port/data cable connection
  4. Square wave input/ground terminal
  5. Corresponds to the function menu selection button at the top of the screen (F1-F4)
  6. Long press the switch/multimeter function to place an order and press as the relative value
  7. Automatic waveform measurement/manual range switching
  8. Keep current data/Long press to save measurement data
  9. Switching oscilloscope/multimeter
  10. Set value adjustment (Up/Down)
  11. Set the value to the left/previous page
  12. Set the value to the right/next page
  13. Mufă de curent 10A
  14. mA current jack
  15. Mufă negativă pentru stiloul Black Watch (COM)
  16. Red watch pen negative jack (VΩHz-f)
  17. Cadru suport pentru spate
  18. Anti-drop silicone layer

4. Configurare și utilizare inițială

4.1 Încărcarea dispozitivului

The AOS03 is equipped with a built-in 3400mAh 3.7V 18650 lithium battery, which can be recharged using the provided Type-C data cable. Connect the Type-C cable to the USB charging port (3) on the device and to a suitable USB power source.

ANENG AOS03 Lithium Battery Direct Charging
Figure 4.1: Charging the AOS03 via its Type-C USB port.

4.2 Pornire/Oprire

Press the power button (6) to turn the device on or off. The device supports automatic shutdown after a period of inactivity to conserve battery life. This setting can be configured in the menu.

4.3 Selectarea limbii

The device supports both Chinese and English languages. You can switch the language through the device settings menu.

5. Instrucțiuni de utilizare

5.1 Funcția multimetrului

The multimeter function allows for precise measurement of various electrical parameters. To switch to multimeter mode, press the dedicated oscilloscope/multimeter switch button (9).

ANENG AOS03 AC/DC Voltage Măsurare
Figura 5.1: ExampVolumul curentului alternativ și curentului continuutage measurements using the multimeter function.
  • AC Voltage (V): Connect the test leads to the VΩHz-f and COM jacks. Select the AC voltage gear and measure across the circuit.
  • DC Voltage (V): Connect the test leads to the VΩHz-f and COM jacks. Select the DC voltage gear and measure across the circuit, observing polarity.
ANENG AOS03 AC/DC Current, Diode, Resistance Measurement
Figura 5.2: Examples of AC/DC current, diode, and resistance measurements.
  • Curent alternativ (A): Connect the test leads to the 10A or mA jack and COM. Select the appropriate AC current gear and measure in series with the circuit.
  • Curent DC (A): Connect the test leads to the 10A or mA jack and COM. Select the appropriate DC current gear and measure in series with the circuit.
  • Testul diodei: Enter the diode gear, touch the positive and negative electrodes of the diode with the test leads.
  • Rezistență (Ω): Enter the resistance gear, measure the resistance value on both sides of the component.
ANENG AOS03 Capacitance and Buzzer Measurement
Figura 5.3: Examples of capacitance and buzzer continuity measurements.
  • Capacitate (F): Enter the capacitor gear and contact both ends of the capacitor. For safety reasons, it is necessary to short-circuit the capacitor before measurement.
  • Buzzer (Continuitate): Enter the buzzer gear, detect on and off, and issue a beep, indicating that the fuse line is unobstructed.

5.2 Funcția osciloscopului

The oscilloscope function allows for real-time waveform visualization and analysis. To switch to oscilloscope mode, press the dedicated oscilloscope/multimeter switch button (9).

5.2.1 Dual Channel Waveform Detection

The AOS03 supports dual-channel input (CH1 and CH2), enabling simultaneous display and comparison of two waveforms. This feature enhances problem diagnosis and signal detection accuracy.

ANENG AOS03 Dual Channel Input Ports
Figure 5.4: Dual channel input ports for oscilloscope function.

Set and connect to the dual-channel input port, select automatic or manual measurement, and press the SAVE button (8) for 2 seconds to save the waveform.

ANENG AOS03 Single Channel vs Dual Channel Comparison
Figure 5.5: Comparison illustrating the advantage of dual-channel measurement over single-channel.

5.2.2 XY Display Mode

To enter XY display mode, navigate to the fifth page of the extended function menu. Press F1 to select X-Y. This mode displays the frequency relationship between CH1 and CH2, producing Lissajous figures of various shapes.

ANENG AOS03 XY Display Mode Examples
Figura 5.6: Examples of Lissajous figures in XY display mode.

5.2.3 Computer View Formă de undă

The AOS03 allows you to view saved waveforms on a computer. Enter the menu on the third page, press F3 to enter the data saving mode. Connect the device to your computer using the USB data cable. The device will appear as a USB disk. Open the 'Pic' folder on the disk to view the saved waveform images.

ANENG AOS03 Computer View Formă de undă
Figure 5.7: Connecting the AOS03 to a computer to view forme de undă salvate.

5.3 Funcția generatorului de semnal

The built-in signal generator can output various waveforms for testing and calibration purposes.

5.3.1 Waveform Output

To output a signal waveform, enter the menu on the sixth page. Press F1 to enter the extended application, select 'signal output', and press the MENU key to confirm and start generating the waveform.

ANENG AOS03 Signal Waveform Output
Figure 5.8: The AOS03 configured for signal waveform output.

5.3.2 Available Waveforms

The signal generator supports the output of 7 different waveforms:

  • Unda sinusoidala
  • Val pătrată
  • Undă triunghiulară
  • Jumătate de val
  • Val plin
  • Val cu dinți de ferăstrău
ANENG AOS03 7 Signal Waveforms
Figure 5.9: Visual representation of the 7 signal waveforms generated by the AOS03.

6. Întreținere

6.1 Îngrijirea bateriei

The device uses a 3400mAh 3.7V 18650 lithium battery. To prolong battery life:

  • Charge the device regularly, especially when the low battery indicator is shown.
  • Evitați descărcarea completă frecventă a bateriei.
  • Depozitați dispozitivul într-un loc răcoros și uscat dacă nu îl utilizați pentru perioade lungi de timp.

6.2 Protecția siguranțelor

The AOS03 features double fuse protection (10A 250V / 600mA 250V) for enhanced safety during current measurements. If the device stops functioning during current measurement, check the fuses. Fuse replacement should only be performed by qualified personnel.

ANENG AOS03 Lithium Battery and Fuse Protection
Figura 6.1: Intern view highlighting the lithium battery and double fuse protection.

6.3 Curățare

Ștergeți dispozitivul cu o lavetă moale și uscată. Nu utilizați produse de curățare abrazive sau solvenți, deoarece acestea pot deteriora dispozitivul.asing sau ecran.

7. Depanare

7.1 Current Measurement Precaution

IMPORTANT: When measuring current, the multimeter must always be connected in series with the circuit. Incorrect connection (e.g., in parallel) can damage the device and the circuit.

ANENG AOS03 Current Measurement Diagram
Figure 7.1: Diagram illustrating the correct method for current measurement in series.

When measuring electric current, pay close attention to the connection method. Do not mix current and voltage measurement modes. Use the multimeter's current file, choose an appropriate range. If the current value is unknown, start with a larger range. If the multimeter displays "1", it indicates an over-range condition. Insert the red pen into the mA hole, the black pen into the COM hole, then disconnect the circuit and connect the pens in series to measure.

7.2 General Malfunctions

If the product is not operating properly, please provide a detailed video of the issue to ANENG customer service. Their experts can quickly diagnose the problem and provide a solution. This brand product is technical and requires a certain degree of electrical knowledge. If you encounter operational problems or do not understand how to use the product, please contact ANENG customer service for assistance.

7.3 Produsul a fost deteriorat artificial

This device is primarily used to detect electrical and other measurement products. It requires careful use and adherence to operating procedures to prevent damage. If the device is used improperly and the use method is not equal, resulting in damage, it will be judged as man-made damage, which is not within the scope of after-sales service. However, you can still contact ANENG customer service to receive a certain amount of coupons to deduct the newly purchased ANENG products.

8. Specificații

8.1 General Technical Specifications for Multimeter

Parametru Valoare
Display (IPS) 25000 conturi
Gamă Automat / Manual
Material ABS+TPE
SampLing Rate 3 ori pe secundă
RMS adevărat
Reținere de date
Iluminare de fundal a ecranului
Indicator baterie descărcată
Oprire automată
Baterie inclusă Da
Baterie IS demontabilă Da
Lungimea înregistrării 128 kbyte
Canale digitale 2
Rezoluția afișajului 800*600 pixeli
Dimensiunea afișajului 3.0 - 4.9 Inches (3.5-inch)
Origine China continentală
Consumabile DIY Electric
ANENG AOS03 Multimeter Technical Indicators Table
Figure 8.1: Detailed multimeter technical indicators.

8.2 Oscilloscope Technical Indicators

Caracteristică Explica Caracteristică Explica
Lățimea de bandă 50MHz Sensibilitate 20mV/div-10V/div
Sampling Metoda În timp real sampling Interval de compensare 4 grile (pozitive și negative)
SampLing Rate 200M/280MSa/s Lățimea de bandă analogică 50MHz
Canal 2 Dual channel Frecventa joasa More than 10Hz
Cuplaj de intrare DC, AC Timp de ridicare Mai puțin de 10ns
Impedanța de intrare 1MΩ, la 16pf Precizia câștigului DC ±3%
Atenuare X1,X10 Măsurare automată Period/Frequency/Peak/Maximum/Minimum/RMS/Duty Cycle/Number of Pulses
Vol. Maxim de intraretage X1range<150V,X10range<300V(DC+AC peak) Moduri de declanșare Auto, normal, singur
Interval de rate 1.5Sa/s-280MSa/s Trigger Edges Marginea ascendentă, marginea descendentă
Interpolare (sinx)x Mod de operare Modul normal 200MSa/s, modul de mare viteză 280MSa/s
Interval de măturare 10ns/div-20s/div Modul de afișare YT / XY / Roll
Baza de timp 20 ppm Modul Afterglow Minim, 500 ms, 1S, 10S, Infinit
Lungimea înregistrării Up to 128kbyte Ieșire generator de semnal Sine wave/square wave/sawtooth wave/half wave/full wave
ANENG AOS03 Oscilloscope Technical Indicators Table
Figure 8.2: Detailed oscilloscope technical indicators.

8.3 Specificații de mediu

Parametru Valoare
Temperatura de operare 0~40℃
Umiditatea de funcționare sub 75%
Temperatura de depozitare -20~60℃
Umiditatea de depozitare sub 80%
Tip baterie 18650 battery*1

9. Sfaturi pentru utilizatori

  • Asigurați-vă întotdeauna că dispozitivul este complet încărcat înainte de măsurători critice pentru a evita întreruperile.
  • For precise oscilloscope readings, use the probe compensation screwdriver to calibrate your probes if necessary.
  • When saving waveforms to a computer, ensure the USB connection is stable to prevent data corruption.
  • Ia avanstage of the dual-channel feature for comparing signals, which can greatly assist in circuit analysis and troubleshooting.
  • Regularly check the test leads for any signs of wear or damage to ensure accurate and safe operation.

10. Garanție și asistență

ANENG is committed to providing excellent after-sales service. If you have any questions or issues regarding your AOS03 device, please refer to the following guidelines:

Informații de asistență post-vânzare ANENG
Figura 10.1: Pesteview of ANENG's after-sales support process.

10.1 Contact for After-Sales Questions

Dacă aveți întrebări în timpul utilizării produsului, vă rugăm să contactați serviciul clienți ANENG. Echipa noastră de asistență clienți vă va oferi soluții satisfăcătoare în timp util.

10.2 About Quality Issues

În cazul unor probleme de calitate, altele decât „daunele provocate de om”, în timpul utilizării acestui produs, se pot oferi servicii de înlocuire sau rambursări. Pentru daune specifice produsului, vă rugăm să contactați serviciul clienți ANENG pentru a confirma și a discuta soluțiile.

  • Metoda de înlocuire: a) Înlocuirea pieselor de schimb, b) Înlocuirea întregii mașini.
  • Metodă de rambursare: a) Rambursare parțială în funcție de piesele deteriorate, b) Rambursare integrală dacă întregul aparat este deteriorat.

10.3 Cerere de înlocuire sau rambursare

Pentru a iniția o cerere de înlocuire sau rambursare:

  1. Contact customer service and provide a product quality problem video for damage determination.
  2. Negociați o soluție.
  3. Distrugeți (spărgeți) produsele cu probleme de calitate pentru a evita deteriorarea secundară.
  4. Executați soluția.

© 2024 ANENG. Toate drepturile rezervate.


Documents - ANENG – AOS03
Aneng AOS03: 3-in-1 Digital Multimeter, Oscilloscope, and Signal Generator
The Aneng AOS03 is a versatile 3-in-1 electronic testing device featuring a digital multimeter, dual-channel oscilloscope, and signal generator with a 3.5" color display and rechargeable battery, ideal for electronics professionals.
scor: 41 filedimensiune: 1.47 M număr_de_pagini: 25 dată document: 2025-09-05
Manual de utilizare a generatorului de semnal multimetru cu osciloscop ANENG AOS03
Manual de utilizare complet pentru ANENG AOS03, un osciloscop cu 2 canale, multimetru și generator de semnal. Acoperă caracteristicile, funcționarea, siguranța și specificațiile tehnice.
scor: 32 filedimensiune: 1.04 M număr_de_pagini: 31 dată document: 2024-11-07
ANENG AOS03 Инструкция: Мультиметр осциллограф 2 канала, генератор сигнала
Руководство пользователя для мультиметра-осциллографа ANENG AOS03 с функцией генератора сигналографа. Описание функций, настроек, измерений и безопасности.
scor: 29 filedimensiune: 1.04 M număr_de_pagini: 31 dată document: 2024-11-07
Manual de utilizare ZOYI ZT-703S: Ghid pentru osciloscop, multimetru, generator de semnal
Ghid complet pentru ZOYI ZT-703S, un dispozitiv portabil 3 în 1, dotat cu un osciloscop cu două canale de 50 MHz, un multimetru digital cu 25,000 de puncte și un generator de semnal cu un ecran IPS de 3.5 inci pentru diverse nevoi de măsurare.
scor: 10 filedimensiune: 1.24 M număr_de_pagini: 40 dată document: 2024-07-27