Delta DVP28SS211R DVP28SS211T

Manual de instrucțiuni PLC seria Delta DVP-SS

Models: DVP28SS211R, DVP28SS211T

1. Introducere

This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the Delta DVP-SS Series Programmable Logic Controllers (PLCs), specifically models DVP28SS211R and DVP28SS211T. The DVP-SS series offers high-speed processing and a compact design, making it suitable for various industrial automation applications. Please read this manual thoroughly before using the product to ensure correct and safe operation.

Delta DVP-12SE PLC unit, front view with indicators and Ethernet port

Figura 1: Față view of a Delta DVP-SS Series PLC, showing indicators and connection ports.

2. Configurare și instalare

Proper installation is crucial for the reliable operation of your Delta DVP-SS Series PLC. Follow these guidelines carefully:

2.1 Considerații de mediu

  • Temperatură: Operate within the specified temperature range (typically 0°C to 55°C).
  • Umiditate: Mențineți umiditatea relativă între 5% și 95% (fără condens).
  • Vibrație: Avoid locations with excessive vibration or shock.
  • Dust and Corrosive Gases: Install in a clean environment free from excessive dust, oil mist, and corrosive gases.
  • Ventilare: Ensure adequate space around the PLC for proper heat dissipation.

2.2 Montare

The DVP-SS series PLCs are typically DIN rail mountable. Ensure the DIN rail is securely fastened to a stable surface. Snap the PLC onto the DIN rail until it clicks into place.

2.3 Cablare

All wiring should be performed by qualified personnel and in accordance with local electrical codes and safety standards.

  • Alimentare electrică: Connect the appropriate DC power supply (e.g., 24V DC) to the designated power terminals. Observe correct polarity.
  • Cablaj de intrare/ieșire: Connect input devices (sensors, switches) to the input terminals and output devices (relays, indicators) to the output terminals. Refer to the specific model's wiring diagram for terminal assignments.
  • Porturi de comunicare: Connect communication cables (e.g., Ethernet, RS-485) to the respective ports for programming or network integration.
Multiple Delta PLC units (DVP28SV, DVP-12SE, DVP-14SS2) showing different models and sizes

Figure 2: Various Delta PLC models, illustrating different form factors and terminal layouts.

3. Instrucțiuni de utilizare

Once installed and wired, the PLC can be programmed and operated.

3.1 Pornire

After verifying all wiring, apply power to the PLC. The 'POWER' indicator should illuminate.

3.2 Programare

Use Delta's WPLSoft or ISPSoft programming software to develop and download your control program to the PLC via the communication port (e.g., USB, RS-232, Ethernet). Ensure the PLC is in 'STOP' mode before downloading a new program.

3.3 Modul Run

After successfully downloading the program, switch the PLC to 'RUN' mode. The 'RUN' indicator should illuminate, and the PLC will begin executing the loaded program. Monitor the 'ERROR' indicator for any faults.

3.4 Monitoring and Debugging

The programming software allows for online monitoring of I/O status, data registers, and program execution. This is essential for debugging and verifying the control logic.

4. Întreținere

Regular maintenance helps ensure the longevity and reliable performance of your PLC.

  • curatenie: Periodically clean the PLC and its enclosure to prevent dust accumulation, which can lead to overheating or short circuits. Use a soft, dry cloth.
  • Verificări de conectare: Regularly inspect all wiring connections for tightness and signs of corrosion. Loose connections can cause intermittent faults.
  • Monitorizarea mediului: Ensure the operating environment remains within specified limits (temperature, humidity, etc.).
  • Actualizări firmware: Verifică-l pe cel al producătorului website for any available firmware updates that may improve performance or address known issues.
  • Înlocuire baterie: If your PLC model includes a battery for retaining data or the real-time clock, follow the manufacturer's instructions for periodic replacement.

5. Depanare

This section outlines common issues and potential solutions for the DVP-SS Series PLC.

5.1 Power Indicator Off

  • Verificați sursa de alimentare: Verificați dacă sursa de alimentare este conectată corect și furnizează voltajul specificat.tage (e.g., 24V DC).
  • Siguranță: Check for blown fuses in the power supply circuit.

5.2 ERROR Indicator On

  • Program Error: Connect to the PLC with programming software to identify the specific error code or message. This often indicates a programming logic error or a hardware fault.
  • Hardware Fault: Inspect for loose connections, damaged wiring, or faulty I/O modules.

5.3 PLC Not Responding to Program Download

  • Setări de comunicare: Verify that the communication settings (port, baud rate) in the software match the PLC's settings.
  • Conexiune prin cablu: Ensure the communication cable is securely connected and not damaged.
  • PLC Mode: Confirm the PLC is in 'STOP' mode before attempting to download.

5.4 I/O Not Functioning Correctly

  • Cablaj: Double-check the wiring of the specific input/output device.
  • Funcționalitatea dispozitivului: Test the input/output device independently to ensure it is working correctly.
  • Program Logic: Review the PLC program to ensure the logic controlling the I/O is correct.

6. Specificații

The following table outlines key specifications for the Delta DVP-SS Series PLCs, including models DVP28SS211R and DVP28SS211T. Specific details may vary slightly between models.

CaracteristicăCaietul de sarcini
Numerele de modelDVP28SS211R, DVP28SS211T
TipStandard Programmable Logic Controller
Consumabile DIYElectric
OrigineChina continentală
Ieșire VoltageStandard
Substanță chimică extrem de îngrijorătoareNici unul

6.1 Produs terminatview Video

Videoclipul 1: Terminatview of various industrial automation products, including PLCs, in their packaging.

7. Sfaturi pentru utilizatori

  • Programe de rezervă: Always back up your PLC programs regularly to prevent data loss.
  • Documentare: Keep detailed documentation of your PLC programs, wiring diagrams, and system configurations.
  • Începeți simplu: When learning or developing new applications, start with simple programs and gradually increase complexity.
  • Siguranța pe primul loc: Always disconnect power before performing any wiring or maintenance to prevent electrical shock.

8. Garanție și asistență

For technical support, warranty claims, or further assistance with your Delta DVP-SS Series PLC, please contact your supplier or the manufacturer directly. Ensure you have your product model and serial number ready when contacting support.

For inquiries related to products purchased from Augety Automation Store, you may use the following contact information:

Contact information for Augety Automation Store, including WhatsApp, WeChat, and Email

Figure 3: Contact details for Augety Automation Store.

Documente conexe - DVP28SS211R DVP28SS211T

Preview Controlere logice programabile (PLC) din seria Delta DVP - Catalog de produse
Explorați gama completă de controlere logice programabile (PLC-uri) din seria Delta DVP, inclusiv modele de control al mișcării, de rețea, standard și I/O analogice. Găsiți specificații detaliate, caracteristici și informații despre comenzi pentru soluții de automatizare industrială.
Preview Delta DVP Series Programmable Logic Controllers: Industrial Automation Solutions
Explore the Delta DVP Series Programmable Logic Controllers (PLCs) for industrial automation. Discover a wide range of high-performance, flexible, and cost-effective solutions designed to meet diverse application needs.
Preview Controlere logice programabile (PLC) din seria Delta DVP - Catalog de produse
Explorați controlerele logice programabile (PLC-uri) din seria Delta DVP, o gamă completă de soluții de automatizare industrială care oferă performanțe ridicate, modele diverse și capacități avansate de control al mișcării. Acest catalog detaliază specificațiile, caracteristicile și informațiile de comandă pentru diverse serii de PLC-uri DVP.
Preview Controlere logice programabile din seria Delta DVP: Soluții de automatizare de înaltă performanță
Explorați seria Delta DVP de controlere logice programabile (PLC-uri), care oferă performanțe ridicate, modele diverse și posibilitatea de extindere pentru aplicații de automatizare industrială. Găsiți specificații detaliate și informații despre produs.
Preview PLC Delta DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP 操作手冊
Delta DVP系列PLC操作手冊,提供ES2、EX2、EC5、SS2、SA2、SX2、SE&TP等型号的详细操作指南、编程方法、通讯设置及故障排除,是工业自动化应用的重要参考文档。
Preview Controlere logice programabile din seria Delta DVP: Ghidul dumneavoastră pentru automatizare digitalizată
Explorați seria Delta DVP de controlere logice programabile (PLC-uri), concepute pentru automatizare digitalizată. Acest catalog cuprinzător detaliază diverse modele, inclusiv seriile DVP-E, DVP-S, DVP-PM și DVP-MC, evidențiind caracteristicile, specificațiile și aplicațiile acestora în automatizarea industrială.