This manual provides instructions for the safe and effective use of the URIT Hb Test Meter (Model PH-01A). This device is designed for convenient and rapid measurement of hemoglobin levels. Please read this manual thoroughly before using the device.

Image: URIT Hb Test Meter PH-01A, showing the device with a digital display.
Conținutul pachetului
Verificați dacă toate articolele enumerate mai jos sunt prezente în colet:
- 1 x URIT Hb Test Meter (Model PH-01A)
- 25 x Hemoglobin Test Strips
- 25 x Lancete
- 1 x dispozitiv de incidere
- 1 x Geanta de depozitare
- 1 x Manual de utilizare (acest document)

Image: Visual representation of the URIT Hb Test Meter kit contents, including the meter, lancing device, test strips, lancets, and storage bag.
Produs terminatview
Familiarize yourself with the components of the URIT Hb Test Meter:

Image: Diagram illustrating the various parts of the PH-01A meter, including Test Strip Inlet, Test Hole, Test Strip Slot, Test Strip Bracket, Code Card Slot, LCD, M Button, On/Off Button, and S Button.
- Test Strip Inlet: Where the test strip is inserted.
- Test Hole: Area for blood sample aplicație.
- Test Strip Slot: Guides the test strip into position.
- Test Strip Bracket: Secures the test strip.
- Code Card Slot: For inserting the code card (if applicable for new strip batches).
- LCD: Liquid Crystal Display for showing results and messages.
- Butonul M: Memory button to review stored results.
- Buton Pornit/Oprit: Pornește sau oprește dispozitivul.
- Buton S: Setting button for time/date or other configurations.
Înființat
Before first use, ensure the meter is ready for operation.
- Instalare baterie: Open the battery compartment on the back of the meter and insert the alkaline batteries, ensuring correct polarity.
- Pornire inițială: Press and hold the On/Off button to power on the meter.
- Setare dată și oră: If prompted, use the M and S buttons to set the correct date and time. Refer to the full manual for detailed instructions on setting these parameters.
- Code Card Insertion: For each new batch of test strips, insert the corresponding code card into the Code Card Slot. The meter will display the code. Remove the code card after the code is read. (Note: The same bottle of test strips does not require repeated settings.)
Instrucțiuni de operare
Quickstart Guide for Hemoglobin Testing

Image: Step-by-step visual quickstart guide for using the URIT Hb Test Meter, showing power on, code card insertion, strip insertion, blood collection, sample application, and result reading.
- Pornire: Press and hold the On/Off button to turn on the meter.
- Insert Code Card (if needed): Insert the code card from the test strip vial, read the code, and then pull out the code card. (This step is not needed for subsequent tests from the same vial).
- Introduceți banda de testare: Turn on the hemoglobin meter and insert a test strip into the Test Strip Inlet.
- Pregătirea dispozitivului de înțepare: Draw a blood sample using the lancing device and lancet included in the package. (Refer to "Blood Collection Steps" below for detailed instructions).
- Aplicați sânge Samppe: When the flashing blood drop symbol appears on the screen, press the top of the test strip and place the blood sample close to the sample entry port of the test strip. The sample will automatically be drawn into the port.
- Citiți rezultatele: Read the test results within 20 seconds on the LCD screen.
Etape de recoltare a sângelui

Image: Visual guide for blood collection, showing hand washing, lancing device assembly, and depth adjustment.
- Spălați-vă pe mâini: Wash your hands thoroughly with soap and water, then dry them completely.
- Pregătirea dispozitivului de înțepare: Pull off the pen cap of the lancing device and insert a new lancet into the fixed frame.
- Secure Lancet: Screw down the blood collection needle cap onto the lancing device.
- Reglați adâncimea de înțepare: Put on the blood collection pen cover and adjust the appropriate gear for different lancing depths (1-5, with 1 being shallow and 5 being deep) to suit your skin type.
- Obțineți sânge Samppe: Press the lancing device firmly against the side of your fingertip and press the release button to prick your finger. Gently squeeze your finger to form a round drop of blood.
Important Considerations for Accurate Results

Image: Infographic detailing key points for accurate hemoglobin test results, including pre-use checks and during-use precautions.
Înainte de utilizare:
- Ensure the test strips are not contaminated, damp, or expired.
- Clean and dry your hands to ensure the blood won't be contaminated.
În timpul utilizării:
- Massage your finger for 10 seconds and lower your arm for 5 seconds before blood sample collection.
- Ensure the blood sample is sufficient each time (10uL micro-sample).
- Avoid touching the contact bar and absorbent hole of the test strip.
Nota:
Consecutive tests are unnecessary as each drop of blood differs, which may cause test results to vary.
Depanare
Why are the results of two consecutive measurements different?

Image: Table outlining factors that affect accuracy and their corresponding solutions for hemoglobin testing.
| Factors that affect accuracy | Soluții |
|---|---|
| Alcohol, dirt, or other substances on your skin | Wash (or use an alcohol pad); please dry your hands and the testing site thoroughly before pricking your skin. |
| Not enough blood was applied to the test strip | Make sure you have enough amount of blood (10uL) for a test. |
| Wipe off tissue contains in your blood | Wipe off the first drop of blood, and then collect a drop of blood on the test strip, making sure you have an adequate amount (10uL) for a reading. |
| Test strip problems | Store strips in their sealed container; keep them away from heat, moisture, and humidity. |
| Testing site location | If you think the value is incorrect in the first test, please change your finger for the second test. |
| Intervalul dintre 2 analize de sânge identice | If the 2 consecutive tests using the same blood are done within 5-10 seconds, there is a slightly different in readings (within 15%). If 2 readings are very different, please check the operation or the above factors, and then test again. |
Întreţinere
Proper maintenance ensures the longevity and accuracy of your URIT Hb Test Meter.
- curatenie: Ștergeți exteriorul contorului cu o lavetă moale șiamp Nu scufundați contorul în apă și nu folosiți agenți de curățare agresivi.
- Depozitare: Store the meter and test strips in the provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Înlocuire baterie: Înlocuiți bateriile când pe afișaj apare indicatorul de baterie descărcată.
- Manipularea benzilor de testare: Always keep test strips in their original sealed container and use them before their expiration date. Close the vial immediately after removing a strip.
Specificații
| Caracteristică | Detaliu |
|---|---|
| Model | PH-01A |
| Producător | URIT |
| Timp de testare | Aproximativ 20 secunde |
| Sample Volumul | 10uL micro-sample |
| Capacitate de memorie | Up to 1,000 test results with time and date records |
| Componente incluse | 1 Meter, 25 Test Strips, 25 Lancets, 1 Storage Bag, 1 Lancing Device |
| Tip baterie | Alcalin |
| Caracteristici speciale | Usor de folosit |
| Dimensiuni pachet | 1.97 x 1.57 x 1.18 inci; 12.35 uncii |
Videoclip oficial al produsului
Video: Official demonstration of the URIT Hemoglobin Test Kit, showing the testing process from preparation to result reading. Duration: 2 minutes, 4 seconds.
Garanție și suport
Specific warranty information for the URIT Hb Test Meter is not provided in the product details. For warranty claims or technical support, please refer to the contact information provided with your product packaging or visit the official URIT website-ul.