AUTOOL LM 120

AUTOOL LM 120 Digital Manifold Gauge Meter User Manual

Model: LM 120

1. Introducere

The AUTOOL LM120+ Refrigeration Digital Manifold Gauge Meter is an intelligent electronic instrument designed for the installation, testing, and maintenance of refrigeration equipment such as air conditioners, refrigerators, and cold storage units. It offers multiple test modes, intelligent digital display, and a built-in refrigerant database for efficient operation, making it a versatile tool for professionals.

AUTOOL LM 120 Digital Manifold Gauge Meter with hoses and clamps

Figure 1: AUTOOL LM 120 Digital Manifold Gauge Meter and accessories.

2. Ghid de instalare

Follow these steps to properly set up your AUTOOL LM 120 Digital Manifold Gauge Meter:

  1. Stare initiala: Before operation, ensure both the low pressure (blue) and high pressure (red) valves on the manifold gauge are in the closed position.
  2. Connect Temperature Clamps: Connect the two temperature-test clamps to their respective sockets on the manifold gauge. These clamps are essential for accurate temperature readings during testing.
    Connecting temperature clamps to the manifold gauge

    Figure 2: Connecting the temperature clamps for high and low pressure temperature testing.

  3. Pornire: Press the power switch on the manifold gauge to turn on the device. The LCD display will illuminate, showing current readings and settings.
  4. Conectați tuburile: Connect the blue, yellow, and red tubes to the corresponding ports on the manifold gauge. Ensure connections are secure to prevent leaks.
  5. Connect Refrigerant Quick Connectors: Attach the refrigerant quick connectors to the appropriate service ports on the refrigeration system (e.g., vehicle AC system). The red connector typically goes to the high-pressure port, and the blue to the low-pressure port.

Video 1: Demonstrates the setup and connection process for the AUTOOL LM 120 Digital Manifold Gauge Meter, including connecting temperature clamps and refrigerant tubes to a vehicle's AC system.

3. Instrucțiuni de utilizare

The AUTOOL LM 120 offers various functions for comprehensive refrigeration system analysis:

3.1. Funcționare cu vid

To perform a vacuum operation, ensure all connections are secure. Open the necessary valves on the manifold gauge to initiate the vacuum process. The gauge will display the vacuum degree, allowing you to monitor the system's evacuation.

3.2. Refrigerant Filling

  1. Connect Refrigerant Container: After vacuuming, connect a new refrigerant container to the yellow service hose of the manifold gauge.
  2. Prepare Vehicle (if applicable): If working on a vehicle, start the engine and adjust the air conditioner to its lowest temperature setting to ensure the system is ready for refrigerant intake.
  3. Inlet Refrigerant: Slowly open the appropriate valves on the manifold gauge to allow the new refrigerant to enter the system. Monitor the pressure readings on the digital display to ensure proper filling.

3.3. Multiple Test Modes

The LM 120 supports various test modes:

  • Dual Pressure Measurement: Measures both high and low pressures simultaneously.
  • Dual Temperature Measurement: Measures high and low pipeline temperatures using the connected test clamps.
  • Vacuum Degree Measurement: Afișează procentultage of vacuum achieved.
  • Pressure Leakage Measurement: Calculates pressure difference over time to detect leaks.
  • Conversia unității: Easily switch between pressure units (Kpa, Mpa, bar, inHg, PSI) and temperature units (Celsius/Fahrenheit).
Evaporation Pressure and Temperature Test on AUTOOL LM 120

Figure 3: Display showing Evaporation Pressure & Temperature Test results.

Condensing Pressure and Temperature Test on AUTOOL LM 120

Figure 4: Display showing Condensing Pressure & Temperature Test results.

Pressure Leakage Test on AUTOOL LM 120

Figure 5: Display showing Pressure Leakage Test results.

3.4. Built-in Database

The LM 120 features a built-in database of 89 kinds of refrigerant pressure and evaporation temperatures. This allows the device to automatically calculate supercooling and superheating temperatures, providing convenient and direct access to critical operational data.

Refrigerant Type Setting and Observation Window on AUTOOL LM 120

Figure 6: Setting refrigerant type and observing filling status through the viewable window.

4. Întreținere

Proper maintenance ensures the longevity and accuracy of your AUTOOL LM 120 Digital Manifold Gauge Meter:

  • curatenie: Regularly wipe the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • Depozitare: After each use, carefully uninstall all quick connectors and tubes. Turn off the manifold gauge. Pack the equipment securely in its carrying case to protect it from dust, moisture, and physical damage.
  • Verificarea componentelor: Periodically inspect the hoses, connectors, and temperature clamps for any signs of wear, cracks, or damage. Replace any worn components to maintain optimal performance and prevent refrigerant leaks.
  • Durabilitate: The LM 120 is constructed with high-strength engineering plastic, flexible non-slip silicone, and copper interfaces, designed for industrial-grade durability. Proper handling and storage will further extend its service life.

5. Depanare

If you encounter issues with your AUTOOL LM 120, consider the following:

  • Citiri inexacte: Ensure all connections are tight and free of leaks. Verify that the correct refrigerant type is selected in the device settings. If persistent, contact customer support for potential calibration needs.
  • Temperature Sensor Issues: Check the connection of the temperature clamps. Ensure they are securely attached to the pipes for accurate readings. If clamps are damaged, they may need replacement.
  • Fără afișaj/alimentare: Check battery levels. Ensure the power button is pressed firmly.
  • Hose Leaks: Inspect hoses and their connections for any visible damage or loose fittings. Tighten connections or replace hoses if necessary.
  • Funcția de vid: Note that the LM 120 measures relative vacuum degree and does not display micron readings. If micron-level vacuum measurement is required, a different model may be necessary.

For issues not covered here, please refer to the detailed product manual or contact AUTOOL customer support.

6. Specificații

ParametruValoare
Numărul de model al articoluluiLM 120
ProducătorAUTOOL
MaterialCrystal, Silicone
Dimensiunile articolului L x l x H0.01 inci
Greutatea articolului950 grame
Dimensiunea ecranului12 inchi
Pressure Test TypePresiunea de suprafață
Pressure Test UnitsKpa; Mpa; bar; inHg; PSI
Interval de testare a presiunii0 Kpa - 6000 Kpa
Rezoluția testului de presiune1 Kpa
Precizia testului de presiune+/- 0.5%(FS)+ 5dgt
Limită de suprasarcină a presiunii10000 Kpa (10 Mpa; 100 bar;)
Vacuum Test TypeRelative vacuum
Vacuum Test UnitsKpa; Mpa; bar; inHg; PSI
Interval de testare în vid-101 Kpa ~ 0 Kpa
Rezoluția testului de vid1 Kpa
Temperature Test Units°C (Celsius), °F (Fahrenheit)
Interval de testare a temperaturii-40°C ~ 150°C (-40°F ~ 302°F)
Rezoluția testului de temperatură0.1°C (-40°C ~ 99.9°C), 1°C (100°C ~ 150°C), 0.1°F (-40°F ~ 99.9°F), 1°F (100°F ~ 302°F)
Precizia testului de temperatură+/- 0.5°C + 2dgt, +/- 0.9°F + 2dgt
Technical Parameters table for AUTOOL LM 120

Figure 7: Detailed technical parameters of the AUTOOL LM 120.

7. Garanție și asistență

AUTOOL stands behind the quality of its products:

  • Garanție de trei ani: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years.
  • Lifelong Maintenance: The product is supported with lifelong maintenance.
  • Asistență clienți: For any inquiries or support needs, AUTOOL offers 24/7 customer support. You can contact them for assistance with product operation, troubleshooting, or warranty claims.
24/7 Customer Support iconPictogramă 3 ani garanție

Figure 8: AUTOOL's commitment to customer support and warranty.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.