1. Produs terminatview
The LYCEBELL 535G is a professional ammonia (NH3) gas detector designed for monitoring ammonia levels in various environments, including households, farms, and industrial facilities. It features an advanced electrochemical sensor for accurate readings, a dual alarm system, and real-time display of temperature and humidity. This portable device is built for reliability and ease of use, ensuring timely detection of ammonia leaks to protect personnel and the environment.
Caracteristici cheie:
- Senzor de înaltă precizie: Utilizes an electrochemical sensor for accurate NH3 detection from 0-100ppm with 0.1ppm resolution and a fast response time of less than 120 seconds.
- Sistem de alarma dublu: Configurable alarm thresholds (AL1 and AL2) with an 80 dB audible alarm and flashing light for immediate alerts.
- Monitorizare în timp real: Displays NH3 concentration, temperature (-10°C to 50°C), and relative humidity (0-95%RH) simultaneously on a large LCD backlight display.
- Portabil și durabil: Equipped with a rechargeable lithium battery providing over 8 hours of continuous operation, APO auto shut-off, and IP54 dust/water protection.
- Ușor de utilizat: One-touch control for alarm settings, unit conversion (°C/°F), and backlight.

2. Conținutul pachetului
Despachetați cu grijă cutia și asigurați-vă că toate articolele sunt prezente și în stare bună. Dacă lipsesc sau sunt deteriorate articole, contactați imediat distribuitorul.
- 1 x LYCEBELL 535G Ammonia Gas Detector
- 1 x cablu de încărcare USB
- 1 x Manual de utilizare
- 1 x Probe Protective Cover

3. Aspectul dispozitivului și comenzile
Familiarize yourself with the device's components and control buttons.

- Ammonia chemical formula (NH3)
- Ammonia concentration display area
- Ammonia gas unit (PPM)
- Level 1 alarm indication (AL1)
- Level 2 alarm indication (AL2)
- Afișaj luminos de fundal
- Indicator de alimentare a bateriei
- Unitate de temperatură (°C/°F)
- Zona de afișare a valorii temperaturii
- Humidity unit (%RH)
- Humidity value display area
- Buton de pornire
- Alarm and backlight button
- Mode and up button
- °C/°F conversion and down button
4. Configurare și utilizare inițială
4.1 Instalarea bateriei (dacă este cazul)
Before first use, ensure the internal rechargeable battery is properly connected. Refer to Figure 2 for an illustration:
- Unscrew the screws of the battery compartment cover.
- Connect the battery, ensuring correct polarity.
- Replace the battery compartment cover and secure with screws.
4.2 Încărcarea dispozitivului
Connect the provided USB charging cable to the Type-C port on the device and to a standard USB power adapter (not included) or computer USB port. The battery indicator on the display will show charging status. A full charge provides over 8 hours of continuous operation.
4.3 Pornire/Oprire
- Pentru pornire: Apăsați și mențineți apăsat butonul Buton de pornire (12) until the display illuminates.
- Pentru a opri: Apăsați și mențineți apăsat butonul Buton de pornire (12) until the display turns off. The device features an Automatic Power Off (APO) function to conserve battery.
4.4 Plasarea dispozitivului
The detector can be placed on a flat surface using its integrated stand or mounted on a wall using the hanging hole on the back.

5. Instrucțiuni de utilizare
5.1 Monitorizare în timp real
Upon powering on, the device will begin real-time monitoring of ammonia concentration (PPM), temperature (°C or °F), and relative humidity (%RH). These values are displayed prominently on the LCD screen.

5.2 Setting Alarm Thresholds
The device features two adjustable alarm levels, AL1 (warning) and AL2 (emergency). When the ammonia concentration exceeds these thresholds, the device will trigger an 80 dB audible alarm and a flashing light.
- Apăsați tasta Buton de alarma (13) to enter alarm setting mode.
- Utilizați Mode (Up) button (14) și °C/°F (Down) button (15) to adjust the AL1 value.
- Apăsați tasta Buton de alarma (13) again to switch to AL2 setting and adjust its value.
- Apăsați tasta Buton de alarma (13) a third time to save settings and exit.
Recommended Alarm Levels:
- AL1 (Warning): e.g., 20 ppm (for early detection)
- AL2 (Emergency): e.g., 250 ppm (for critical exposure levels)

5.3 Conversia unităților de măsură (°C/°F)
To switch between Celsius (°C) and Fahrenheit (°F) for temperature display, briefly press the °C/°F (Down) button (15).
5.4 Control iluminare de fundal
To toggle the display backlight, briefly press the Buton de alarma (13).
6. Întreținere
6.1 Curățare
Ștergeți dispozitivul cu o lavetă moale și uscată. Nu utilizați produse de curățare abrazive sau solvenți, deoarece acestea pot deteriora dispozitivul.asing or sensor. Ensure the device is powered off before cleaning.
6.2 Îngrijirea bateriei
Recharge the device when the battery indicator shows low power. Avoid fully discharging the battery frequently to prolong its lifespan. If storing the device for an extended period, charge it periodically to maintain battery health.
6.3 Sensor Protection
Always use the provided probe protective cover when the device is not in use to shield the sensor from dust and physical damage.
6.4 Depozitare
Depozitați dispozitivul într-un loc răcoros și uscat, ferit de lumina directă a soarelui și de temperaturi extreme. A nu se lăsa la îndemâna copiilor.
7. Depanare
If you encounter issues with your LYCEBELL 535G Ammonia Gas Detector, refer to the following common problems and solutions:
| Problemă | Cauza posibila | Soluţie |
|---|---|---|
| Dispozitivul nu pornește. | Low battery or battery not connected. | Charge the device using the USB cable. Ensure the internal battery is correctly connected (refer to Section 4.1). |
| Citiri inexacte. | Sensor contamination or device not calibrated. | Ensure the sensor area is clean and free from obstructions. Avoid exposing the sensor to extreme conditions. If issues persist, contact customer support for potential recalibration. |
| Alarm not sounding/flashing. | Alarm thresholds set too high or alarm function disabled. | Check and adjust alarm thresholds (AL1, AL2) as described in Section 5.2. Ensure the ammonia concentration exceeds the set thresholds. |
| Afișajul este slab iluminat sau ilizibil. | Backlight off or low battery. | Press the Alarm button (13) to toggle the backlight. Charge the device if the battery is low. |
If the problem persists after attempting these solutions, please contact LYCEBELL customer support or your retailer for further assistance.
8. Specificații
Technical specifications for the LYCEBELL 535G Ammonia Gas Detector:
| Parametru | Valoare |
|---|---|
| Numărul de model | LC-535G |
| Detectarea gazului | amoniac (NH3) |
| Tip senzor | electrochimică |
| Domeniul de măsurare | 0-100 ppm |
| Rezoluţie | 0.1 ppm |
| Eroare de bază | ±5% (F.S) |
| Timp de răspuns | <120 de secunde |
| Repetabilitate | <1% |
| Interval de temperatură | -10°C to 50°C (±2°C accuracy) |
| Intervalul de umiditate | 0-95% RH (fără condensare) |
| Tip alarmă | Audible (80 dB) and Visual (flashing light) |
| Baterie | Baterie reîncărcabilă cu litiu |
| Durata de viață a bateriei | >8 hours (continuous use) |
| Port de încărcare | Tip-C USB |
| Evaluare de protecție | IP54 (Dust and splash protected) |
| Dimensiuni (L x l x H) | 12.8 x 0.9 x 3.7 cm (5.03 x 0.35 x 1.46 țoli) |
| Greutate | 320 de grame |
9. Garanție și asistență
9.1 Informații despre garanție
For detailed warranty information regarding your LYCEBELL 535G Ammonia Gas Detector, please refer to the warranty card included with your purchase or contact the retailer from whom you purchased the product. Warranty terms and conditions may vary by region and retailer.
9.2 Asistență pentru clienți
If you have any questions, require technical assistance, or need to report an issue that cannot be resolved using the troubleshooting guide, please contact LYCEBELL customer support or your authorized retailer. Please have your product model number (LC-535G) and purchase details ready when contacting support.