Introducere

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Asurity by Diversitech CP-22LPT Low Profile Condensate Pump. This pump is designed to automatically evacuate condensate or water discharge from HVACR equipment, offering a vertical lift capability of up to 22 feet. Its low-profile design makes it suitable for installations in tight spaces.

Informații de siguranță

Citiți cu atenție toate instrucțiunile înainte de instalare și utilizare. Nerespectarea acestor instrucțiuni poate duce la daune materiale, vătămări corporale sau deces.

  • Pericol electric: Disconnect power before servicing. This unit operates on 110 Volts. Ensure all electrical connections comply with local codes.
  • Pericol de apă: This pump handles water. Ensure proper drainage and prevent water damage.
  • Instalare: Install the pump in a location where it is accessible for maintenance and inspection.
  • Utilizare prevăzută: Use this pump only for its intended purpose of evacuating condensate from HVACR equipment.
  • Listat UL: This product is UL listed, meeting electrical and mechanical safety standards for water pumps.

Conținutul pachetului

Verificați dacă toate elementele sunt prezente înainte de a începe instalarea:

  • Asurity by Diversitech CP-22LPT Condensate Pump
  • 20 ft Clear Vinyl Tubing
  • 4 ft Safety Switch Wire (pigtail)

Produs terminatview

The Asurity CP-22LPT condensate pump features a compact design with advanced functionalities for reliable condensate removal.

Asurity CP-22LPT Condensate Pump with Clear Tubing

Imaginea 1: The Asurity CP-22LPT low profile condensate pump shown with the included clear vinyl tubing. The pump features a red base and a black motor housing with ventilation slots and an outlet port.

Asurity CP-22LPT Condensate Pump with Tubing and Safety Switch Wire

Imaginea 2: Un de sus în jos view of the Asurity CP-22LPT condensate pump, accompanied by the coiled clear vinyl tubing and the yellow safety switch wire. This image highlights all primary components included with the unit.

Latura View of Asurity CP-22LPT Condensate Pump

Imaginea 3: A side perspective of the Asurity CP-22LPT condensate pump, illustrating its low-profile design. This view emphasizes the compact dimensions suitable for installation in confined spaces.

Caracteristici cheie:

  • LED Status Indicator Lights (Power, Run, Alarm)
  • Vibrația Dampening System for quiet operation
  • Integrated Safety Switch with 4 feet of wire for air-handler shutdown
  • Pro scăzutfile design for tight installations
  • Metal mounting tabs for secure installation
  • Four inlet holes (with 3 poly covers for unused ports)
  • Float switch and duckbill-style check valve

Configurare și instalare

Proper installation is crucial for the pump's performance and longevity. Ensure all local electrical and plumbing codes are followed.

  1. Plasare: Position the pump on a level surface near the HVACR unit. The low-profile design is ideal for tight spaces. Utilize the vibration dampening feet and metal mounting tabs for secure placement.
  2. Racord admisie condens: Connect the condensate drain line from the HVACR unit to one of the pump's inlet holes. The pump has four inlet holes; seal any unused inlets with the provided poly covers.
  3. Conectarea liniei de refulare: Connect the 20 ft clear vinyl tubing to the pump's discharge outlet. Route the tubing upwards, ensuring it does not exceed the pump's 22 ft vertical lift capability, and then to a suitable drain point. Avoid kinks or sharp bends in the tubing. The integrated duckbill-style check valve prevents backflow.
  4. Conexiune electrică: Connect the pump to a dedicated 110V power supply. Ensure the power source is off before making connections.
  5. Conectarea comutatorului de siguranță: Connect the 4 ft safety switch wire (pigtail) to the air-handler's shutdown circuit. This feature is designed to shut down the HVACR unit if the pump fails or the water level rises too high, preventing overflow. Refer to your HVACR unit's manual for specific wiring instructions for the safety switch.
  6. Testare: After installation, manually pour water into the pump's reservoir to verify proper operation. The pump should activate, discharge the water, and then shut off. Check for any leaks.

Instrucțiuni de operare

The Asurity CP-22LPT condensate pump operates automatically once properly installed and powered.

  • When condensate water enters the pump's reservoir and reaches a predetermined level, the internal float switch activates the pump.
  • The pump will then discharge the water through the connected vinyl tubing to the designated drain.
  • Once the water level drops, the float switch deactivates the pump.
  • Indicatoare LED:
    • Pwr (Power): Illuminates when the pump is receiving electrical power.
    • Run: Illuminates when the pump motor is actively discharging water.
    • Alrm (Alarm): Illuminates if the water level rises to the high-level alarm switch, indicating a potential issue and activating the safety shutdown circuit.

Întreţinere

Întreținerea regulată asigură o performanță optimă și prelungește durata de viață a pompei de condens.

  • Inspecție lunară: Check the pump reservoir for sludge, mold, or debris. Clean as necessary.
  • curatenie: Disconnect power before cleaning. Remove the pump cover and clean the reservoir with a mild detergent and water. Ensure the float switch moves freely.
  • Linie de refulare: Inspect the vinyl tubing for blockages, kinks, or leaks. Clear any obstructions.
  • Orificii de admisie: Ensure inlet ports are clear of debris.

Depanare

Consultați tabelul următor pentru problemele comune și soluțiile acestora.

Problemă Cauza posibila Soluţie
Pompa nu funcționează No power; Clogged inlet/outlet; Stuck float switch; Motor failure Check power supply; Clear blockages; Inspect/clean float switch; Contact support if motor fails
Pompa funcționează continuu Stuck float switch; Leak in discharge line; Pump undersized for flow rate Inspect/clean float switch; Check for leaks; Verify pump capacity meets demand
Water overflow / Alarm LED on Pump failure; Clogged discharge line; Safety switch activated Check pump operation; Clear discharge line; Investigate cause of high water level
Zgomot/vibrații excesive Debris in pump; Improper mounting; Worn motor bearings Clean pump; Ensure secure mounting; Contact support for motor issues

Specificații

Caracteristică Detaliu
Marca Diversitech (Asurity)
Numărul de model CP-22LPT
Voltage 110 volți
Sursa de alimentare Electric cu fir
Ridicare maximă 22 picioare
Debit maxim 1.6 galoane pe minut
Dimensiunile produsului 12 cm L x 6.75 cm l x 6 cm Î
Greutatea articolului 5.41 lire sterline
Material Plastic
Culoare Roșu Negru
Componente incluse Condensate Pump, 20ft clear vinyl tubing, 4ft safety switch wire (pigtail)
Certificari Listat UL

Garanție și suport

For warranty information or technical support, please contact Diversitech customer service. Keep your purchase receipt for warranty claims.

Producător: Diversitech

Website: www.diversitech.com

Contact: Consultați instrucțiunile producătorului website pentru informații de contact actuale.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.