DX-SMART LR02

DX-Smart LR02 LoRa Module User Manual

Model: LR02

Manufacturer: DX-SMART

1. Introducere

The DX-Smart LR02 is a low-power LoRa module designed for wireless data transmission. It integrates an ASR6601 RF chip and supports UART serial communication, enabling transparent data transfer between devices. This module operates within the 433~475MHz frequency range and is suitable for various Internet of Things (IoT) applications requiring long-range and low-power connectivity.

Caracteristicile cheie includ:

  • ASR6601 SOC Chip with 32-bit ARM STAR Core.
  • Maximum Frequency: 48MHz.
  • UART Serial Communication with configurable baud rates (1200 to 128000).
  • Extensive AT command set for module configuration.
  • Support for 410~493MHz frequency range, ensuring global compatibility.
  • High power PA with +22dBm output.
  • Maximum Receiver Sensitivity: -138dBm.
  • Supports sleep mode and wake-on-air mode.
  • Line-of-sight distance up to 5km in open areas.
  • Vol. De operaretage: 3.3V-5.5V (typical: 5V).
  • Module Size: 36(L)x16.5(W)x4(H)mm.
  • CE, FCC, RoHS certified.

2. Setup and Hardware Connection

This section details the physical connection of the LR02 module, including pinout and wiring diagrams. Ensure correct polarity when connecting the module to an adapter board or development environment.

2.1 Module Pinout

The LR02 module features a standard pinout for easy integration. Refer to the diagram below for pin identification and function.

LR02 Module Pinout and Wiring Diagram

Figura 2.1: LR02 Module Pinout and Example Wiring Diagram. The diagram illustrates the pin assignments for the LR02 module and a typical connection to an adapter plate, showing connections for M0, M1, PXD, TXD, RXD, AUX, VCC, and GND.

  • M0, M1: Reserved, customizable IO ports.
  • PXD: Not explicitly defined in the diagram, but typically related to data transmission.
  • TXD: UART Transmit Data.
  • RXD: UART Receive Data.
  • AUX: Auxiliary pin (refer to detailed documentation for specific functions).
  • VCC: Power Supply (3.3V-5.5V).
  • GND: Sol.

2.2 Starea indicatorului

The module includes an indicator light to show its operational status:

  • Stare de lucru: Red light blinking.
  • Mod de hibernare: Light off when hibernating, red light flashing when waking up.

3. Operating Modes and AT Commands

The LR02 module supports various working modes and is configured using a comprehensive set of AT commands via its UART serial interface. This allows for flexible integration into different applications without requiring custom LoRa programming.

3.1 Supported Working Modes

The module can operate in three primary data transmission modes:

LR02 Module Working Modes and AT Command Set

Figura 3.1: Illustration of LR02 Module Working Modes (Transparent, Fixed-Point, Broadcast) and a partial AT Command Set. The diagram visually explains how data is transmitted in each mode and lists common AT commands for configuration.

  1. Module and Module Transparent Transmission: Requires the same channel for both sender and receiver to transmit data.
  2. Module and Module Fixed-Point Transmission: Communicates with modules using specified addresses and channels. Data format is hexadecimal: receiving address + receiving channel + data.
  3. Modules and Module Broadcast Transmission: Communicates with designated channel modules. Data format is hexadecimal: receiver channel + data.

3.2 AT Command Set

AT commands are used to configure and query the module's parameters. A serial port testing software can be used for this purpose.

Serial Port Testing Software and AT Command Examples

Figura 3.2: Screenshot of a UART Assistant Tools software demonstrating serial port testing and a table of common AT commands. This image shows how to interact with the module using AT commands and a software interface.

Comenzile AT comune includ:

  • LA: Test command (responds with OK).
  • +++: Enter/exit AT command mode.
  • AT+BAUD: Set/query baud rate.
  • AT+MODE: Set/query operating mode.
  • AT+SLEEP: Set/query power consumption mode.
  • AT+CHANNEL: Set/query working channels.
  • AT+MAC: Set/query device address.
  • AT+POWE: Set/query transmit power.
  • AT+IQ: Setting the IQ signal flip-flop.

For a complete list and detailed usage of AT commands, please consult the product information packages and technical documentation provided by DX-SMART.

4. Întreținere

The DX-Smart LR02 module is designed for robust operation. To ensure its longevity and reliable performance, consider the following general maintenance guidelines:

  • Conditii de mediu: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, moisture, or corrosive environments.
  • Manipulare fizică: Handle the module with care to prevent physical damage to components or solder joints. Avoid excessive force when connecting or disconnecting antennas and cables.
  • Alimentare electrică: Ensure a stable and clean power supply within the specified voltage range (3.3V-5.5V). Unstable power can affect performance and module lifespan.
  • curatenie: Dacă este necesar, curățați ușor modulul cu o cârpă moale și uscată. Evitați utilizarea lichidelor sau a substanțelor chimice dure.
  • Actualizări firmware: Verificați periodic producătorul website for any available firmware updates that may improve performance or add new features. Follow the provided instructions carefully for any update procedures.

5. Depanare

If you encounter issues with your DX-Smart LR02 module, consider the following troubleshooting steps:

  • No Power/Indicator Off:
    • Verificați volumul sursei de alimentaretage este între 3.3V-5.5V.
    • Verificați toate conexiunile de alimentare pentru contactul și polaritatea corecte.
    • Ensure the module is not in hibernation mode (indicator light off).
  • Communication Failure (UART):
    • Confirm TXD and RXD lines are correctly connected (TX of one device to RX of the other).
    • Verify that the baud rate settings on both the module (via AT commands) and the host device match.
    • Verificați dacă există conexiuni slăbite sau fire deteriorate.
    • Ensure the module is not in sleep mode, which would prevent communication.
  • Poor Wireless Range/Connectivity:
    • Ensure the antenna is securely connected and appropriate for the operating frequency.
    • Check for obstructions between modules (e.g., thick walls, metal objects).
    • Verify that both modules are configured to the same frequency and channel.
    • Confirm transmit power settings using AT commands.
  • Module Not Responding to AT Commands:
    • Ensure you are sending the correct AT command prefix (e.g., '+++' to enter command mode).
    • Check serial port settings (baud rate, data bits, parity, stop bits).
    • Confirm the module is powered on and not in a deep sleep state.

If problems persist after following these steps, please refer to the technical support section for further assistance.

6. Specificații

Detailed technical specifications for the DX-Smart LR02 LoRa Module:

LR02 Module Key Features and Dimensions

Figura 6.1: Visual representation of the LR02 module highlighting key features and physical dimensions (35.6mm length, 18mm width, 2.54mm pin pitch).

ParametruDetaliu
Model de cipASR6601
Interfață de comunicarePort serial UART
Tip fără firRadio Frequency (LoRa)
Banda de frecventa433~475MHz (Supports 410~493MHz)
Puterea de transmisie+22dBm
Sensibilitatea receptorului-138 dBm
Distanța de comunicareUp to 5km (line-of-sight in open areas)
Suport rată baud1200, 2400, 9600, 19200, 38400, 57600, 115200, 128000
Vol. De operaretage3.3V-5.5V (Typical: 5V)
Temperatura de operare-40°C până la +85°C
Dimensiuni modul (L x l x H)36 mm x 16.5 mm x 4 mm
CertificariCE, FCC, RoHS
Drone Measured Communication Distance of LR02 Module

Figura 6.2: Image illustrating a drone-measured communication distance test, showing the LR02 module achieving a visible range of up to 5km in an open environment. Note: Actual performance may vary based on environmental factors.

7. Informații despre garanție

Specific warranty terms for the DX-Smart LR02 LoRa Module are typically provided at the point of purchase or within the product packaging. For detailed warranty information, including coverage period and conditions, please refer to the documentation supplied by your seller or contact DX-SMART directly.

8. Technical Support and Resources

DX-SMART provides comprehensive technical support and resources to assist with the integration and operation of the LR02 module. These resources include:

  • Documentatie tehnica: Detailed datasheets, user guides, and application notes.
  • AT Command Sets: Full documentation of all available AT commands for advanced configuration.
  • Module Footprints and Reference Design Schematics: For hardware integration.
  • Development/Test Tools: Software and hardware tools to aid in development and testing.

For further assistance or to access these resources, please contact DX-SMART customer service. You can typically find contact information through the 'User Guide', 'Product Information', or 'Service Support' sections on the manufacturer's official website-ul sau prin intermediul furnizorului produsului dumneavoastră.

© 2024 DX-SMART. All rights reserved.

Acest manual poate fi modificat fără notificare prealabilă.

Ask a question about this manual