1. Introducere

This manual provides detailed instructions for the installation, operation, and maintenance of your BHI 12,000 BTU 115-Volt, 17 SEER2, Wi-Fi Ductless Mini Split Air Conditioner with Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage or injury. Keep this manual for future reference.

The BHI mini-split system is designed to provide efficient cooling and heating for spaces up to 600 sq. ft., featuring Wi-Fi connectivity for convenient control and a heat pump for year-round comfort.

2. Informații de siguranță

Respectați întotdeauna următoarele măsuri de siguranță pentru a reduce riscul de incendiu, electrocutare sau vătămare corporală.

  • Instalare profesională necesară: Instalarea, întreținerea și repararea acestui aparat trebuie efectuate de către personal de service calificat. Instalarea necorespunzătoare poate duce la electrocutare, incendiu sau scurgeri de apă.
  • Siguranta electrica: Ensure the power supply matches the unit's specifications (115-Volt). Do not use extension cords. Always disconnect power before servicing.
  • Siguranța agentului frigorific: This unit contains R410A refrigerant. Handle with care and ensure proper ventilation during installation and servicing.
  • Autorizații: Mențineți distanțe adecvate în jurul unităților interioare și exterioare pentru o circulație a aerului corespunzătoare și acces la service.
  • Copii și animale de companie: Țineți copiii și animalele de companie departe de unitate în timpul funcționării și întreținerii.
  • Fără obstacole: Do not block the air inlet or outlet of either unit.
  • Drenarea apei: Ensure proper drainage for condensate to prevent water damage.

3. Conținutul pachetului

La despachetare, verificați dacă toate componentele sunt prezente și nedeteriorate. Dacă lipsesc sau sunt deteriorate articole, contactați imediat furnizorul.

BHI Mini Split Air Conditioner complete package including indoor unit, outdoor unit, remote control, and lineset.

Figure 3.1: Complete BHI Mini Split Air Conditioner System Components.

This image displays the full package contents, including the indoor air handler, the outdoor condenser unit, the wireless remote control, and the 16.4 ft. pre-charged lineset, along with other installation accessories.

  • Indoor Unit (Air Handler)
  • Unitate exterioară (condensator)
  • Telecomanda fara fir
  • 16.4 ft. Pre-charged Lineset
  • Furtun de scurgere
  • Cablaje electrice
  • Installation Accessories (e.g., wall sleeve, insulation tape)
  • Manual de utilizare (acest document)

4. Caracteristicile produsului

  • 4.1 Control Wi-Fi

    Illustration of Wi-Fi control for BHI mini split AC.

    The BHI mini split system features integrated Wi-Fi connectivity, allowing users to easily control the air conditioner from outside the home via a smart device. This provides convenient and intelligent life management of your indoor climate.

  • 4.2 Outdoor Unit Heating Belt

    BHI outdoor unit with heating belt component highlighted.

    The BHI Outdoor Unit is equipped with a "Heating Belt" that operates via a temperature sensor. If the ambient temperature drops below 32°F (0°C), the heating belt will automatically activate to prevent the outdoor unit from freezing. It will deactivate once the temperature rises above 32°F (0°C), ensuring reliable operation in cold climates.

  • 4.3 "I Set" Function

    Remote control with 'I Set' button and air conditioner.

    The "I Set" function allows the unit to automatically memorize your preferred settings. With just one button press, you can recall your customized comfort preferences, simplifying operation.

  • 4.4 "I Feel" Function and Louver Position Memory

    Diagram showing 'I Feel' function with remote sensor and Louver Position Memory.

    I Feel: This feature utilizes a built-in temperature sensor in the remote controller to monitor the surrounding temperature more accurately. This allows the air conditioner to adjust the room temperature precisely, providing enhanced comfort.

    Louver Position Memory: The unit remembers the last louver position. When the unit is restarted, the louvers will automatically return to their previously set position.

5. Configurare și instalare

Installation of this mini split system requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC professional to ensure safety, proper operation, and warranty validity.

Dimensiuni 5.1 unitate

Dimensions of BHI indoor and outdoor mini split units.

Figure 5.1: Indoor and Outdoor Unit Dimensions.

This image provides detailed measurements for both the indoor air handler and the outdoor condenser unit, crucial for planning installation space and clearances.

  • Unitate interioară:
    • Latime: 30.59 inchi
    • Înălțime: 11.91 inci
    • Adâncime: 9.84 inci
  • Unitate exterioară:
    • Latime: 30.59 inchi
    • Înălțime: 19.63 inci
    • Adâncime: 11.41 inci

5.2 General Installation Steps (Overview pentru profesioniști)

  1. Amplasarea unității interioare: Select a suitable location on an interior wall, ensuring adequate space for airflow and maintenance.
  2. Amplasarea unității exterioare: Choose a stable, level outdoor location with sufficient clearance for airflow and service access.
  3. Găurire gaură în perete: Create a hole through the wall for the refrigerant lines, drain hose, and electrical cables.
  4. Conexiune linie: Connect the pre-charged 16.4 ft. lineset between the indoor and outdoor units. Ensure proper flaring and torque.
  5. Cablaj electric: Connect the power supply and communication wiring according to the wiring diagram provided with the unit. Ensure proper grounding.
  6. Conexiune de drenaj: Connect the condensate drain hose from the indoor unit to an appropriate drainage point.
  7. Aspirare și test de scurgeri: Evacuate the refrigerant lines to remove air and moisture, then perform a leak test.
  8. Run test: After installation, perform a test run to verify proper operation in all modes.

6. Instrucțiuni de utilizare

Your BHI mini split system is controlled primarily by the wireless remote control. Familiarize yourself with the remote's functions for optimal use.

BHI Mini Split Air Conditioner remote control.

Figura 6.1: Telecomandă fără fir.

This image shows the layout of the wireless remote control, which is used to operate the BHI mini split air conditioner.

6.1 Funcții de control de la distanță

ButonFuncţie
Putere (⏻)Pornește sau oprește unitatea.
MODComută între modurile de funcționare: Auto, Răcire, Uscare, Încălzire, Ventilator.
TEMP (▲/▼)Reglează temperatura setată.
FANReglează viteza ventilatorului (Auto, Mică, Medie, Mare).
SWING (↕/↔)Controls vertical (up/down) and horizontal (left/right) louver swing.
TIMERSets the ON/OFF timer for automatic operation.
TURBOActivează răcirea sau încălzirea rapidă pentru schimbări bruște de temperatură.
ECOActivează modul de economisire a energiei.
MUTESilences beeps or sounds from the unit.
DORMIOptimizează temperatura și viteza ventilatorului pentru un somn confortabil.
AFIŞATurns the indoor unit's display ON or OFF.
SIMTActivates the remote's temperature sensor for more accurate room temperature sensing.
AM SETATRecalls previously saved preferred settings.

6.2 Controlul aplicației Wi-Fi

For Wi-Fi control, download the dedicated BHI smart app from your device's app store. Follow the in-app instructions to connect your mini split unit to your home Wi-Fi network. Once connected, you can control the unit's functions remotely, set schedules, and monitor its status.

7. Întreținere

Regular maintenance ensures the longevity and efficiency of your BHI mini split system. Always disconnect power to the unit before performing any maintenance.

7.1 Curățarea filtrului de aer

The indoor unit's air filters should be cleaned every two weeks or more frequently depending on usage and air quality.

  1. Deschideți panoul frontal al unității interioare.
  2. Scoateți filtrele de aer.
  3. Clean the filters using a vacuum cleaner or wash them with lukewarm water and mild detergent.
  4. Lăsați filtrele să se usuce complet într-o zonă umbrită înainte de a le reinstala.
  5. Reinstalați filtrele și închideți panoul frontal.

7.2 Curățarea unității exterioare

Periodically inspect the outdoor unit for debris, leaves, or dirt that may obstruct airflow. Gently clean the coils with a soft brush or water hose. Do not use high-pressure water directly on electrical components.

7.3 Servicii profesionale

It is recommended to have a qualified HVAC technician perform annual professional maintenance, including checking refrigerant levels, electrical connections, and overall system performance.

8. Depanare

Înainte de a contacta serviciul de asistență, repetațiview următoarele probleme comune și potențialele lor soluții.

ProblemăCauza posibilaSoluţie
Unitatea nu pornește.Fără alimentare cu energie electrică; Bateriile telecomenzii sunt descărcate; Întrerupătorul de circuit s-a declanșat.Verificați conexiunea la alimentare; Înlocuiți bateriile telecomenzii; Resetați întrerupătorul de circuit.
Răcire/încălzire insuficientă.Dirty air filters; Blocked outdoor unit; Incorrect mode setting; Low refrigerant.Clean air filters; Clear obstructions from outdoor unit; Select correct mode; Contact professional for refrigerant check.
Scurgeri de apă din unitatea interioară.Furtun de scurgere înfundat; Instalare necorespunzătoare.Clear drain hose; Contact professional for inspection.
Zgomot neobișnuit.Loose parts; Fan obstruction; Compressor issue.Check for loose parts; Clear obstructions; Contact professional.
Probleme cu conexiunea Wi-Fi.Parolă Wi-Fi incorectă; Router prea departe; Probleme cu aplicația.Verify password; Move router closer or use extender; Reinstall app.

If the problem persists after attempting these solutions, please contact BHI customer support or a qualified service technician.

9. Specificații

AtributDetaliu
Numărul de modelBHI-T17-12K115V-US-C
Capacitatea de racire12,000 BTU
Voltage115-Volți
Evaluare SEER217 SEER2
Zona de acoperirePână la 600 sq. ft.
Tipul de agent frigorificR410A
Lungimea setului de linii16.4 ft. (Pre-charged)
Dimensiuni produs (unitate interioară)30.59 x 11.91 x 9.84 inchi (L x A x A)
Dimensiuni produs (unitate exterioară)30.59 x 19.63 x 11.41 inchi (L x A x A)
Greutatea articolului68.33 de livre (greutate totală a sistemului)
ProducătorBHI

10. Garanție și asistență

For specific warranty terms and conditions, please refer to the warranty card included with your product packaging or visit the official BHI webPăstrați dovada achiziției pentru reclamații în garanție.

If you require technical assistance, have questions about operation, or need to report an issue, please contact BHI customer support. Contact information can typically be found on the manufacturer's website-ul sau în ambalajul produsului.

© 2024 BHI. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.