CONTIA DH48J-11A

CONTIA DH48J-11A Digital Counter Relay User Manual

Model: DH48J-11A

1. Introducere

This manual provides detailed instructions for the installation, operation, and maintenance of the CONTIA DH48J-11A Digital Counter Relay. Please read this manual thoroughly before using the device to ensure proper function and safety.

2. Produs terminatview

The DH48J-11A is an 11-pin digital counter relay designed for industrial applications requiring precise event counting. It features a digital display, various input signal options, and a reset function.

Faţă view of the CONTIA DH48J-11A Digital Counter Relay

Figura 2.1: Față view of the DH48J-11A Digital Counter Relay, showing the 4-digit display and dial switches for setting.

3. Caracteristici

  • Digital 4-digit display for clear count indication.
  • Supports various input signals: contact, level, and NPN type sensors.
  • Multiple supply voltage options: 110V, 220V, 380V AC; 12V, 24V AC/DC; 24-240V AC/DC.
  • Up and down counting modes with magnification settings (x1, x10, x100).
  • Built-in reset function.
  • No-power memory for up to 10 years (for DH48J-11A model).
  • SPDT control form with high contact rating.
  • Compact external dimensions (48x48x97 mm).

4. Variații ale modelului

The DH48J series includes several models with specific input signal capabilities:

  • DH48J-8: Designed for input from relays, limit switches, etc. Includes a reset function.
  • DH48JA: Optimized for proximity sensors, photoelectric sensors, etc.
  • DH48J-11A: Versatile model accepting input from relays, limit switches, and various sensors. Includes a reset function and 10-year no-power memory.

5. Specificații

Parametru Caietul de sarcini
Numărul de model DH48J series (DH48J-11A)
Volumul aprovizionăriitage 110, 220, 380 Vac (50/60 Hz); 12Vac/Vdc, 24Vac/Vdc; 24-240VAC/DC
Mod de operare Up Counting, Down Counting
Gama de numărare 1-9999 (with magnification up to x100, total 1-999900 events)
Semnal de intrare Contact, Level, Sensor (NPN type)
Viteză maximă de numărare 30 cps (counts per second)
Min. Counting Pulse 15 ms
No-power Memory 10 years (for DH48J-11A)
Control Form SPDT (Single Pole Double Throw)
Evaluarea contactului 5A@250Vac, 7A@24Vdc
Viața mecanică 1 x 107 operațiuni
Viața electrică 1 x 105 operațiuni
Consumul de energie 5 W max
Metoda de setare Comutator de apelare
Indication Method 8-segment 4-digital display
Dimensiuni exterioare 48 x 48 x 97 mm (lățime x înălțime x adâncime)
Perforate Dimensions 46 x 46 mm
Eroare de numărare 1 cifre
Reset Time anii 0.05
Resetare alimentare 1s
Rezistenta dielectrica 2000Vac, 50/60Hz for 1 minute
Manual sheet showing dimensions and sequence diagram for DH48J-11A

Figure 5.1: Diagram illustrating external and perforate dimensions, and a sequence diagram for the DH48J-11A.

6. Instalare și cablare

The DH48J-11A counter relay is designed for panel mounting. A compatible 11-pin relay socket (e.g., PF113A) is recommended for installation.

Configurație cu 6.1 pini

Spate view of the DH48J-11A showing 11 pins

Figura 6.1: Spate view of the DH48J-11A, illustrating the 11-pin base for socket connection.

6.2 Schema electrică

Refer to the diagram below for correct wiring connections. Ensure power is disconnected before performing any wiring.

Wiring diagram for DH48J-A timer

Figure 6.2: Wiring diagram for the DH48J-A series, applicable to DH48J-11A. This diagram shows connections for power source, input signal (CP), reset, and relay contacts.

Conexiuni cheie:

  • Sursa de alimentare: Connect the appropriate AC or DC voltage to the designated pins (e.g., pins 2 and 7 for 220VAC, or as indicated on the unit for other voltages).
  • Input Signal (CP): Connect your counting signal source (contact, level, or NPN sensor) to the CP input pin (e.g., pin 10).
  • Resetați: Connect a momentary switch to the Reset pin (e.g., pin 9) to clear the current count.
  • Ieșire releu: The SPDT relay contacts are typically available on pins 1, 3, 4, 5, 6, 8. Refer to the diagram for specific Normally Open (NO) and Normally Closed (NC) configurations.
  • +12V / 0V: These pins (e.g., pins 8 and 11) may provide auxiliary power for external sensors if applicable to your model.

Caution: Incorrect wiring can damage the device or lead to unsafe conditions. Always verify connections against the diagram and local electrical codes.

7. Funcționare

7.1 Setting the Count Value and Magnification

The DH48J-11A uses dial switches on the front panel to set the target count value and magnification factor (x1, x10, x100). Adjust these dials to your desired settings. The 4-digit display will show the current count.

  • Magnification (x1, x10, x100): This setting determines how many input events are required for the display to increment by one unit. For example, if set to x10, the display will increment by 1 after 10 input signals.
  • Interval de numărare: The counter can display values from 1 to 9999. With magnification, the total countable events can reach 999900.

7.2 Moduri de numărare

  • Up Counting: The display increments with each detected input signal, based on the set magnification.
  • Down Counting: The display decrements with each detected input signal, based on the set magnification.

7.3 Funcția de resetare

To reset the counter to zero, press the 'RESET' button on the front panel or activate the external reset input (pin 9). The reset time is approximately 0.05 seconds.

7.4 Power Reset

Upon power-up, the counter performs a power reset, which takes approximately 1 second before normal operation resumes.

8. Întreținere

The DH48J-11A Digital Counter Relay is designed for reliable operation with minimal maintenance. Follow these guidelines:

  • Păstrați dispozitivul curat și ferit de praf și umezeală.
  • Asigurați o ventilație adecvată pentru a preveni supraîncălzirea.
  • Regularly inspect wiring connections for tightness and signs of wear.
  • Avoid exposing the device to strong vibrations or corrosive environments.

9. Depanare

If the counter is not functioning as expected, consider the following common issues:

  • Fără afișaj/Fără alimentare: Verificați volumul sursei de alimentaretage and wiring connections. Ensure the correct voltage variant of the counter is being used.
  • Not Counting: Verify the input signal source and its connection to the CP pin. Ensure the input signal type (contact, level, NPN sensor) is compatible with the DH48J-11A. Check the minimum counting pulse duration (15ms).
  • Incorrect Count: Review the magnification setting on the dial switches. Ensure the input signal is clean and free from noise that could cause false counts.
  • Reset Not Working: Check the connection to the reset pin or the functionality of the front panel reset button.
  • Ieșirea releului nu se activează: Confirm that the count has reached the set target value. Check the relay output wiring and the load connected to it.

For persistent issues, consult a qualified technician or contact customer support.

10. Garanție și asistență

For information regarding warranty coverage, technical support, or service, please refer to the product packaging or contact your vendor. Keep your purchase receipt for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.