Legrand 3414971882614

Legrand Double Pre-wired Socket 2x2P+T 16A 250V~ Waterproof Plexo Grey IP55 IK08 Instruction Manual

1. Introducere

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of your Legrand Double Pre-wired Socket. This product is designed for surface mounting and offers robust protection with an IP55 rating for dust and water resistance, and an IK08 rating for impact resistance, making it suitable for various environments.

2. Informații de siguranță

AVERTIZARE: Electrical installations must be carried out by a qualified electrician in accordance with national and local wiring regulations. Failure to follow these instructions can result in electric shock, fire, or serious injury.

  • Always disconnect power at the main circuit breaker before performing any work on the electrical system.
  • Ensure the product is suitable for the intended environment and load.
  • Nu modificați produsul în niciun fel.
  • Țineți copiii departe de instalațiile electrice.
  • Verificați ca toate conexiunile să fie sigure și corecte înainte de a restabili alimentarea cu energie electrică.
  • The IP55 rating ensures protection against dust and low-pressure water jets. The IK08 rating indicates protection against 5 joules of impact.

3. Produs terminatview

The Legrand Double Pre-wired Socket (Model: 3414971882614) is a robust electrical outlet designed for demanding applications. It features two 2P+T (2 Pole + Earth) sockets, pre-wired for convenience, and is rated for 16A at 250V~. Its grey Plexo design ensures durability and resistance to environmental factors.

3.1. Componente incluse

  • Plexo New FRUP Socket with protective contact (Double Pre-wired Socket)

3.2. Produs Views

Legrand Double Pre-wired Socket, top-down view with covers open
Figura 1: De sus în jos view of the Legrand Double Pre-wired Socket with protective covers open, showing the two 2P+T outlets. This view highlights the robust construction and the IP55 marking.
Legrand Double Pre-wired Socket, angled view with covers open
Figura 2: Înclinat view of the Legrand Double Pre-wired Socket with protective covers open. This perspective shows the side profile and the overall compact design suitable for surface mounting.

4. Configurare și instalare

This section details the steps for installing your Legrand Double Pre-wired Socket. Ensure all safety precautions are followed before beginning.

4.1. Instrumente necesare

  • Screwdriver (appropriate size for terminals and mounting screws)
  • Stripteuze sârmă
  • Drill (for mounting, if necessary)
  • Nivel de spirit
  • Creion

4.2. Mounting the Socket

  1. Deconectați alimentarea: Turn off the power supply at the main circuit breaker to the circuit where the socket will be installed. Verify with a voltage tester.
  2. Pozitionare: Choose a suitable location for surface mounting. Mark the drilling points for the mounting screws using the socket base as a template.
  3. Găuri: Drill pilot holes if required, ensuring they are appropriate for your mounting surface and screws.
  4. Bază sigură: Attach the socket base securely to the wall or surface using appropriate screws. Ensure it is level.

4.3. Conexiuni de cablare

The Legrand Double Socket is pre-wired, simplifying the connection process. You will connect the main power supply to the designated terminals.

  1. Pregătiți cablurile: Route the electrical cables to the socket location. Strip the outer sheath and insulation from the individual conductors (Phase, Neutral, Earth) to the length specified in the product documentation or by the terminal design. Note: Some users recommend a slightly longer stripping length for these terminals compared to standard Wago connectors.
  2. Conectează firele:
    • Connect the Phase (Live) wire to the 'L' terminal.
    • Conectați firul neutru la terminalul „N”.
    • Connect the Earth (Ground) wire to the 'PE' or Earth symbol terminal.
    Ensure all wires are fully inserted and securely clamped in their respective terminals.
  3. Puncte de intrare sigilate: Ensure cable entry points are properly sealed to maintain the IP55 rating.
  4. Închideți coperta: Carefully close the front cover of the socket, ensuring no wires are pinched. Secure it with the provided screws.
  5. Restabiliți puterea: După finalizarea și verificarea instalării, restabiliți alimentarea cu energie la întrerupătorul principal.

5. Instrucțiuni de utilizare

Operating the Legrand Double Pre-wired Socket is straightforward.

  1. Deschideți capacul: Lift the protective cover of the desired socket.
  2. Introduceți ștecherul: Insert the plug of your electrical appliance into the socket. Ensure it is fully seated.
  3. Close Cover (Optional): For continued IP55 protection, ensure the protective cover is closed when no plug is inserted or when the plug is inserted and the cover can still close around the cable (if designed for this). The "Schieber" (slider) mechanism helps maintain tightness when a plug is connected.
  4. Scoateți ștecherul: To disconnect, firmly pull the plug from the socket.

Nota: Always ensure the appliance connected does not exceed the socket's maximum rating of 16A, 250V~.

6. Întreținere

Regular maintenance ensures the longevity and safe operation of your Legrand socket.

  • curatenie: Clean the exterior of the socket with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the protective covers are free from dirt and debris to maintain proper sealing.
  • Inspecţie: Periodically inspect the socket for any signs of damage, such as cracks, discoloration, or loose components. Check the integrity of the seals and cable glands.
  • Verificarea conexiunii: If accessible and safe to do so (with power disconnected), periodically check the tightness of the terminal connections.
  • Protecția mediului: Ensure the protective covers are closed when the socket is not in use to maintain its IP55 rating against dust and water.

7. Depanare

If you encounter issues with your Legrand Double Pre-wired Socket, refer to the following common troubleshooting steps.

ProblemăCauza posibilaSoluţie
Fără alimentare de la priză.
  • Întrerupătorul s-a declanșat.
  • Conexiunea cablajului slab.
  • Aparat defect.
  • Verificați și resetați întrerupătorul.
  • With power disconnected: Verificați etanșeitatea tuturor conexiunilor cablajului.
  • Test the appliance in another known working socket.
Socket feels warm.
  • Circuit supraîncărcat.
  • Conexiune slabă.
  • Disconnect some appliances. Ensure total load does not exceed 16A.
  • With power disconnected: Check all wiring connections for tightness. If problem persists, consult a qualified electrician.
Protective cover does not close properly.
  • Obstrucţie.
  • Damage to hinge or latch.
  • Clear any debris or foreign objects.
  • Inspect for physical damage. If damaged, the IP55 rating may be compromised, and replacement may be necessary.

If the problem persists after attempting these solutions, contact a qualified electrician or Legrand customer support.

8. Specificații

CaracteristicăDetaliu
MarcaLegrand
Numărul de model3414971882614
TipDouble Pre-wired Socket 2x2P+T
Evaluare curentă16 A
Voltage Evaluare250 V~
MaterialPlastic
CuloareGri
Evaluare de protecție la pătrundere (IP).IP55 (Dust protected, protected against low-pressure water jets from any direction)
Clasificare de protecție la impact (IK)IK08 (Protected against 5 joules of impact)
Tip de montareMontare la suprafață
Greutate270 grame
Componente inclusePlexo New FRUP Socket with protective contact
Țara de origineGermania

9. Garanție și asistență

For warranty information and technical support, please refer to the official Legrand website-ul web sau contactați distribuitorul local Legrand. Păstrați bonul fiscal ca dovadă a achiziției.

Puteți vizita magazinul Legrand de pe Amazon pentru mai multe produse și informații: Magazinul Amazon Legrand