The AUTOOL LM110+ Digital Refrigeration Manifold Gauge is an advanced instrument designed for the installation, testing, and maintenance of refrigeration equipment, including air conditioners and cold storage units. This device offers digital readings, multi-unit switching, and a built-in database of 89 refrigerants for accurate measurements.

AUTOOL LM110+ Digital Refrigeration Manifold Gauge main unit

Figure 1: AUTOOL LM110+ Digital Refrigeration Manifold Gauge main unit. This image shows the front view of the digital manifold gauge, highlighting its display and control buttons.

Key functionalities include refrigerant filling and pressure inspection, vacuum testing, and pressure leakage testing. Its robust design features high-strength engineering plastics and flexible non-slip silicone for durability and comfortable handling.

2. Caracteristici

  • Ecran digital: Large LCD display with backlight for clear readings in various lighting conditions.
  • Construcție robustă: Made from high-strength engineering plastics and flexible non-slip silicone for durability. Features heavy-duty valve switches and 1/4-inch imports.
  • Multifuncțional: Supports refrigerant filling, pressure inspection, vacuum testing, and pressure leakage testing with time record.
  • Tehnologie avansată: Incorporates a 32-bit digital processing unit and high-precision data acquisition unit for efficient and stable performance.
  • Refrigerant Database: Built-in database of 89 refrigerants (NIST) for accurate pressure condensation and evaporation temperature readings.
  • Monitorizare în timp real: Detects and displays original pressure, current pressure, leakage pressure, and test time during leak tests. Shows current vacuum pressure and vacuum percentage during vacuum operations.
  • Fereastra de observare: A visual window allows observation of the refrigerant filling status.

3. Specificații

AUTOOL LM110+ Digital Refrigeration Manifold Gauge specifications

Figure 2: Detailed specifications of the AUTOOL LM110+ Digital Refrigeration Manifold Gauge. This image provides a visual summary of the technical data.

ParametruValoare
Pressure Test TypePresiune manometrică
Pressure Test UnitsKPa, MPa, Bar, inHg, PSI
Interval de testare a presiunii0 KPa – 6000 KPa
Rezoluția testului de presiune1 KPa
Precizia testului de presiune+/- 0.5 %(FS) + 5dgt
Limită de suprasarcină a presiunii10000 KPa (10 MPa; 100 bar)
Vacuum Test TypeVid relativ
Vacuum Test UnitsKPa, MPa, Bar, inHg, PSI
Interval de testare în vid-101 KPa – 0 KPa
Rezoluția testului de vid1 KPa
Built-in Refrigerants89 types (NIST)
Alimentare electrică3 x 1.5V (SIZE.AA / LR6)
Dimensiuni (L x l x H)200 x 150 x 130 mm (7.87 x 5.91 x 5.12 țoli)
Weight (excludes battery)1.046 kg (2.31 lb)
MaterialSilicone, Engineering Plastics

4. Configurare

Before using the AUTOOL LM110+ Digital Refrigeration Manifold Gauge, ensure proper setup:

  1. Instalare baterie: Open the battery compartment and insert three 1.5V AA/LR6 batteries, ensuring correct polarity.
  2. Racord pentru furtun: Connect the test pipes (hoses) to the appropriate ports on the manifold gauge and to the refrigeration system being serviced. Ensure all connections are secure to prevent leaks.
  3. Pornire: Press the power button to turn on the device. The LCD display should illuminate.
  4. Refrigerant Selection: Use the device's controls to select the specific refrigerant type (e.g., R134a, R410a) relevant to your application from the built-in database.
AUTOOL LM110+ Digital Refrigeration Manifold Gauge applicable scenes

Figura 3: Examples of applicable scenes for the AUTOOL LM110+ Digital Refrigeration Manifold Gauge, including automobile air conditioning, household air conditioning, cold storage, and general refrigeration equipment.

5. Instrucțiuni de utilizare

5.1 Refrigerant Filling and Pressure Inspection

This function is used for refrigeration system repair, maintenance, refrigerant filling, and operation inspection. The built-in refrigerant database provides pressure condensation and evaporation temperature readings.

  1. Connect the gauge to the refrigeration system according to standard procedures for refrigerant charging.
  2. Select the correct refrigerant type on the device.
  3. Monitor the pressure readings and corresponding condensation/evaporation temperatures on the display during the filling process.
AUTOOL LM110+ Digital Refrigeration Manifold Gauge refrigerant filling and testing display

Figure 4: Display showing refrigerant filling and testing. This image illustrates how the gauge displays refrigerant type, condensation/evaporation temperature, measuring unit, and pressure during operation.

5.2 Vacuum Operation and Testing

The vacuum operation mode tests the vacuum pressure value and calculates the vacuum degree of the refrigeration system.

  1. Connect the gauge to the system for vacuuming.
  2. Activate the vacuum test function on the device.
  3. Observe the real-time display of current vacuum pressure and the percentage of vacuum level.
AUTOOL LM110+ Digital Refrigeration Manifold Gauge vacuuming operation and testing display

Figure 5: Display showing vacuuming operation and testing. This image demonstrates the gauge's ability to show vacuum degree, measuring unit, and pressure during vacuum tests.

5.3 Test de scurgere de presiune

The pressure leak test function is used to inspect how much pressure changes over a specific time after a refrigeration system has been filled with refrigerant or vacuumed.

  1. After charging or vacuuming, initiate the pressure leak test.
  2. The device will display the original pressure, current pressure, leakage pressure (difference), and the elapsed test time.
  3. Monitor these values to determine if there is a leak in the system.
AUTOOL LM110+ Digital Refrigeration Manifold Gauge leak testing of pressure display

Figure 6: Display showing leak testing of pressure. This image illustrates how the gauge displays leak pressure, measuring unit, measuring pressure, original pressure, and testing time.

5.4 Comutarea unităților

The LM110+ supports various pressure and temperature unit displays for user convenience.

  • Unități de presiune: KPa, MPa, Bar, PSI, inHg.
  • Unități de temperatură: °C, °F.

Refer to the device's buttons for switching between units as needed during operation.

AUTOOL LM110+ Digital Refrigeration Manifold Gauge unit switching display

Figure 7: Display showing support for various unit switching. This image highlights the multiple pressure units (KPa, MPa, Bar, PSI, inHg) and temperature units (°C, °F) available on the gauge.

5.5 Refrigerant Observation Window

The manifold gauge includes a visual window to observe the refrigerant filling status, allowing for better control and monitoring during charging.

AUTOOL LM110+ Digital Refrigeration Manifold Gauge refrigerant observation window

Figure 8: Close-up of the refrigerant observation window. This image shows the transparent window on the gauge, allowing users to visually inspect the refrigerant flow and status.

6. Întreținere

To ensure the longevity and accuracy of your AUTOOL LM110+ Digital Refrigeration Manifold Gauge, follow these maintenance guidelines:

  • curatenie: Ștergeți dispozitivul cu o lavetă moale și uscată. Nu utilizați substanțe de curățare abrazive sau solvenți.
  • Depozitare: Store the gauge in a clean, dry place away from extreme temperatures and direct sunlight. Use the provided package box for protection when not in use.
  • Înlocuire baterie: Replace batteries promptly when the low battery indicator appears to prevent data loss or device malfunction. Remove batteries if the device will not be used for an extended period.
  • Inspecția furtunului: Regularly inspect test pipes for cracks, wear, or damage. Replace damaged hoses immediately to ensure accurate readings and prevent refrigerant leaks.
  • Calibrare: While the device is factory calibrated, periodic checks against known standards are recommended for professional use to maintain accuracy.

7. Depanare

If you encounter issues with your AUTOOL LM110+ Digital Refrigeration Manifold Gauge, consider the following common troubleshooting steps:

  • Dispozitivul nu pornește:
    • Verificați dacă bateriile sunt instalate corect și au o încărcare suficientă. Înlocuiți-le cu baterii noi, dacă este necesar.
    • Asigurați-vă că compartimentul bateriei este bine închis.
  • Citiri inexacte:
    • Verify that the correct refrigerant type is selected on the device.
    • Check all hose connections for leaks. Even small leaks can affect pressure readings.
    • Ensure the system is properly purged of air before taking measurements.
    • If persistent, consider professional calibration.
  • Probleme de afișare:
    • If the backlight is not working, check battery levels.
    • If the display is frozen or showing erratic characters, try turning the device off and on again.
  • Leak Test Fails/Indicates Leak:
    • Double-check all connections on the refrigeration system and the gauge itself.
    • Perform a visual inspection for obvious signs of refrigerant leakage (e.g., oil residue).
    • If a leak is confirmed, locate and repair it before retesting.

Pentru problemele care nu sunt rezolvate prin acești pași, vă rugăm să contactați serviciul de asistență pentru clienți.

8. Garanție și asistență

AUTOOL provides a warranty for the LM110+ Digital Refrigeration Manifold Gauge. For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years from the date of purchase.

For any technical assistance, warranty claims, or product inquiries, please contact AUTOOL customer support. We aim to respond to all inquiries within 24 hours.

Informații de contact: Refer to the product packaging or the official AUTOOL website pentru cele mai recente date de contact.

© 2026 AUTOOL. Toate drepturile rezervate.

Acest manual poate fi modificat fără notificare prealabilă.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.