WINGONEER 4r

WINGONEER 50Kg Body Load Cell Weighing Sensor Instruction Manual

Model: 4r

1. Introducere

This manual provides essential information for the proper installation, operation, and maintenance of the WINGONEER 50Kg Body Load Cell Weighing Sensor. This half-bridge strain gauge sensor is designed for various weighing applications, particularly suitable for DIY projects involving microcontrollers like Arduino. Please read this manual thoroughly before use to ensure safe and effective operation.

2. Produs terminatview

The WINGONEER 50Kg Body Load Cell is a compact and robust weighing sensor. It operates on the principle of resistance strain, where the electrical resistance changes in proportion to the applied mechanical stress. This sensor is configured as a half-bridge, requiring an external full-bridge circuit or two such sensors to form a full bridge for accurate measurement.

De sus în jos view of the WINGONEER 50Kg Body Load Cell with attached wires.

Figura 1: De sus în jos view of the WINGONEER 50Kg Body Load Cell with attached wires. The sensor features a central load-bearing element and four color-coded wires for connection.

Fund view of the WINGONEER 50Kg Body Load Cell, showing the mounting points.

Figura 2: De jos view of the WINGONEER 50Kg Body Load Cell, illustrating the structural design and mounting points for secure installation.

Înclinat view of the WINGONEER 50Kg Body Load Cell, highlighting its compact design.

Figura 3: Înclinat view of the WINGONEER 50Kg Body Load Cell, showcasing its overall form factor and wire connections.

3. Specificații

ParametruValoare
Capacitate50 kg
TipHalf-Bridge Strain Gauge
Sensibilitatea la ieșire1.0 ± 0.1 mV/V
Neliniaritate0.05% FS
histerezis0.05% FS
Repetabilitate0.05% FS
Creep (30 min)0.05% FS
Temperature Effect on Zero0.05% F.S./10°C
Temperature Effect on Span0.05% F.S./10°C
Rezistență de intrare1000 ± 10 Ohm
Rezistența la ieșire1000 ± 10 Ohm
Rezistenta de izolare≥ 2000 MΩ (100VDC)
Temperatura de operare-10°C până la +50°C
Recommended Excitation Voltage5-10 VDC
Maximum Excitation Voltage15 VDC
MaterialAliaj de aluminiu
CablajRed (E+), Black (E-), White (O-), Green (O+)

4. Configurare

4.1 Mounting the Load Cell

Securely mount the load cell to a stable, rigid surface using appropriate fasteners. Ensure that the load is applied directly to the designated sensing area of the load cell. Avoid applying off-center or twisting forces, as this can lead to inaccurate readings and potential damage.

4.2 Instrucțiuni de cablare

The 50Kg Body Load Cell is a half-bridge sensor. To form a complete Wheatstone bridge for measurement, you will typically need two such half-bridge sensors or one half-bridge sensor combined with two fixed resistors. An HX711 ADC (Analog-to-Digital Converter) module is commonly used with these sensors for signal amplification and digital conversion.

The sensor has four color-coded wires:

  • Roşu: Excitation+ (E+)
  • Negru: Excitation- (E-)
  • Alb: Output- (O-)
  • Verde: Output+ (O+)

When connecting to an HX711 module:

  • Conectați-vă Roşu wire to E+ on HX711.
  • Conectați-vă Negru wire to E- on HX711.
  • Conectați-vă Alb wire to A- on HX711.
  • Conectați-vă Verde wire to A+ on HX711.

For a full-bridge configuration using two half-bridge sensors:

  1. Connect Red wires of both sensors together to the positive excitation voltage.
  2. Connect Black wires of both sensors together to the negative excitation voltage (ground).
  3. Connect the Green wire of the first sensor to the White wire of the second sensor. This connection point will be one of your differential outputs (e.g., A+ on HX711).
  4. Connect the White wire of the first sensor to the Green wire of the second sensor. This connection point will be your other differential output (e.g., A- on HX711).

Nota: Always refer to the specific documentation of your ADC module (e.g., HX711) for precise wiring diagrams and calibration procedures.

5. Instrucțiuni de utilizare

5.1 Calibrare

After wiring, calibration is crucial for accurate measurements. This typically involves:

  1. Calibrare zero: With no load on the sensor, take a reading. This establishes the baseline or 'tare' value.
  2. Calibrare span: Apply a known weight (calibration weight) to the sensor and take a reading. Use this reading and the known weight to calculate the sensor's conversion factor (e.g., grams per ADC unit).

Most microcontroller libraries for HX711 or similar ADCs provide functions for these calibration steps.

5.2 Preluarea măsurătorilor

Once calibrated, the sensor will output a raw analog signal proportional to the applied load. The ADC module converts this into a digital value. Your microcontroller code will then apply the calibration factor to convert this digital value into a meaningful unit of weight (e.g., grams, kilograms).

Ensure the load is applied smoothly and centrally to the load cell for consistent readings. Avoid sudden impacts or vibrations during measurement.

6. Întreținere

The WINGONEER 50Kg Body Load Cell is designed for durability and requires minimal maintenance. Follow these guidelines:

  • Păstra curat: Regularly clean the sensor surface to prevent accumulation of dust or debris that could interfere with its operation. Use a soft, dry cloth.
  • Evitați supraîncărcarea: Do not exceed the rated capacity of 50 kg. Overloading can permanently damage the strain gauges.
  • Protejați de mediu: While robust, protect the sensor from excessive moisture, extreme temperatures, and corrosive substances unless specifically designed for such environments.
  • Inspectați cablarea: Periodically check the wiring for any signs of wear, fraying, or loose connections.

7. Depanare

  • Citiri inexacte:
    • Cauza posibila: Calibrare necorespunzătoare. Soluţie: Re-calibrate the sensor following the steps in Section 5.1.
    • Cauza posibila: Unstable mounting or off-center load. Soluţie: Ensure the load cell is securely mounted and the load is applied centrally.
    • Cauza posibila: Electrical noise. Soluţie: Use shielded cables, keep signal wires away from power lines, and ensure stable power supply to the ADC and microcontroller.
  • No Readings/Sensor Not Responding:
    • Cauza posibila: Cablare incorectă. Soluţie: Double-check all wire connections against the diagram in Section 4.2.
    • Cauza posibila: Faulty ADC module or microcontroller. Soluţie: Test the ADC module and microcontroller with a known working setup if possible.
    • Cauza posibila: Celula de sarcină deteriorată. Soluţie: Inspect the load cell for physical damage. If damaged, replacement may be necessary.
  • Readings Drift Over Time:
    • Cauza posibila: Fluctuații de temperatură. Soluţie: Ensure the operating environment is stable. Some drift is inherent in strain gauges, but significant drift may indicate an issue.
    • Cauza posibila: Creep. Soluţie: For long-term measurements, allow the sensor to stabilize under load before taking final readings.

8. Garanție și asistență

No specific warranty information is provided for this product. For technical support or inquiries, please refer to the vendor or manufacturer's contact information available at the point of purchase.

© 2023 WINGONEER. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.