On-Q 36456902V1

Legrand On-Q Surge-Protected Duplex Power Kit (Model 36456902V1)

Manual de instructiuni

1.view

The Legrand On-Q Surge-Protected Duplex Power Kit (Model 36456902V1) provides a convenient and secure solution for delivering power and surge protection to equipment within structured wiring enclosures, wall installations, and other compatible setups. This kit is designed to safeguard sensitive electronics from voltage spikes while offering a tamper-resistant outlet for enhanced safety.

Legrand On-Q Surge-Protected Duplex Power Kit

Image 1.1: The Legrand On-Q Surge-Protected Duplex Power Kit, showing the complete product assembly.

2. Informații de siguranță

Please read and understand all instructions before installation and use. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • AVERTIZARE: Risk of electric shock. Disconnect power at the circuit breaker or fuse box before installing or servicing.
  • Instalarea trebuie efectuată de către un electrician calificat, în conformitate cu toate codurile electrice naționale și locale.
  • Do not install in wet locations or where excessive moisture may be present.
  • Asigurați-vă că toate conexiunile cablajului sunt sigure și izolate corespunzător.
  • Acest dispozitiv este destinat numai utilizării în interior.
  • Do not exceed the electrical ratings of the device (15 Amps, 125 volți).

3. Conținutul trusei

Verificați dacă toate componentele sunt prezente înainte de a începe instalarea:

  • Surge-Protected Duplex Outlet
  • Old-Work Electrical Box
  • Placă de perete
  • Șuruburi de montare
Kit Contents: Surge-Protected Outlet, Old-Work Electrical Box, Wall Plate

Image 3.1: This image shows the components included in the kit: a surge-protected outlet, an old-work electrical box, and a wall plate.

4. Caracteristici

  • Built-In Surge Protection: Safeguards connected devices with integrated surge protection, ideal for powering and protecting equipment in structured wiring enclosures. Provides 340 Joules of surge protection and 24kA Max Surge Capability.
  • Surge Protection Details: 340 Joules, 24kA Max Surge Capability

    Image 4.1: This image illustrates the surge protection capabilities, including 340 Joules of surge protection and 24kA Max Surge Capability.

  • Audible Alarm with ON/OFF: An integrated audible alarm alerts users to surge protection status. A switch allows the alarm to be turned on or off.
  • Audible Alarm with ON/OFF switch on outlet

    Image 4.2: This image highlights the audible alarm feature with an ON/OFF switch on the outlet.

  • Surge Protection LED Indicator: A visual LED indicator provides immediate status feedback:
    • Steady GREEN = Protected
    • Flashing RED = Not Protected
    • OFF = No Power to Unit
  • Surge Protection LED Indicator states

    Image 4.3: This image explains the Surge Protection LED Indicator: steady green for protected, flashing red for not protected, and off for no power.

  • TampDesign rezistent la erori: Ensures safety by preventing accidental insertion of foreign objects into the outlet slots.
  • Instalare versatilă: Compatible with On-Q and other enclosures featuring standard outlet knockouts, or can be used as a standard wall outlet.
  • Durabil și fiabil: Construit cu materiale de înaltă calitate pentru performanțe de lungă durată.
  • Additional Wiring Flexibility: Features 2 back wire holes for easier wiring.
  • Outlet features: Removable Ears, Child-Safe Tamper Resistant Shutters, 2 Back Wire holes

    Image 4.4: This image details the outlet's specifications, including removable ears, child-safe tamper-resistant shutters, 2 back wire holes, and 15A 125Volt 60Hz cULus listing.

5. Instalare

Follow these steps for proper installation of the Legrand On-Q Surge-Protected Duplex Power Kit:

5.1. Pregătire

  1. Deconectați alimentarea: Turn off power at the main circuit breaker or fuse box before starting any electrical work. Verify power is off using a voltage tester.
  2. Selectați locația: Choose a suitable location within your structured wiring enclosure or wall for the power kit.
  3. Remove Knockouts: If installing in an enclosure, use a utility knife and hammer to carefully remove the desired electrical knockouts for the power kit.

5.2. Cablare și montare

  1. Install Electrical Box: Insert the provided old-work electrical box into the prepared opening. Use the provided screws to affix the box securely to the enclosure or wall stud.
  2. Cablajul traseului: Route the AC cabling (hot, neutral, ground) into the electrical box.
  3. Terminate AC Cabling: Connect the AC wires to the surge-protected duplex receptacle. Ensure proper polarity (hot to brass screw, neutral to silver screw, ground to green screw). Tighten all terminal screws firmly.
  4. Priză de montare: Carefully push the wired receptacle into the electrical box. Screw the receptacle into the box using the provided mounting screws.
  5. Instalați placa de perete: Attach the wall plate over the receptacle and secure it with the provided screws.

Video 5.1: This video demonstrates the installation process for the On-Q power kit, showing how to remove knockouts, install the electrical box, wire the receptacle, and secure the cover plate.

Diagram showing compatibility with standard knockouts in enclosures

Image 5.2: This image shows a diagram illustrating how the power kit is compatible with standard knockouts on both metal and plastic media enclosures.

Installed power kit inside an enclosure providing power and surge protection

Image 5.3: This image shows the installed power kit inside an enclosure, providing power and surge protection to networking equipment.

6. Funcționare

Once installed and power is restored, the Legrand On-Q Surge-Protected Duplex Power Kit operates automatically to provide power and surge protection.

6.1. Surge Protection Indicator

Observe the LED indicator on the outlet for its status:

  • Steady GREEN: Indicates that the surge protection is active and functioning correctly.
  • ROȘU intermitent: Indicates that the surge protection has been compromised or is no longer providing protection. The outlet will still provide power, but connected devices are no longer protected from surges. Replacement of the unit is recommended.
  • OPRIT: Indicates no power is supplied to the unit. Check the circuit breaker or wiring connections.

6.2. Alarmă sonoră

The audible alarm will sound if the surge protection is compromised (flashing RED LED). Use the ON/OFF switch located on the outlet to silence or activate the alarm as needed.

7. Întreținere

The Legrand On-Q Surge-Protected Duplex Power Kit requires minimal maintenance. Regular checks are recommended to ensure continued protection.

  • Inspecție vizuală: Periodically inspect the outlet and wiring for any signs of damage, wear, or loose connections.
  • Verificare indicator LED: Regularly check the LED indicator to ensure it is steady green, indicating active surge protection. If it is flashing red, the surge protection has been expended, and the unit should be replaced.
  • curatenie: Clean the surface of the outlet and wall plate with a soft, dry cloth. Do not use abrasive cleaners or solvents.

8. Depanare

If you encounter issues with your Legrand On-Q Surge-Protected Duplex Power Kit, refer to the following troubleshooting guide:

ProblemăCauza posibilaSoluţie
No power to outlet (LED OFF)Circuit breaker tripped; Loose wiring connection; No power to circuit.Check and reset circuit breaker. Verify all wiring connections are secure. Ensure power is supplied to the circuit.
LED is flashing RED (Audible alarm may sound)Surge protection has been expended due to a power surge.The surge protection components are no longer functional. The outlet will still provide power, but it no longer protects against surges. Replace the entire unit to restore surge protection.
Audible alarm sounds continuouslySurge protection is compromised.Check the LED indicator. If flashing RED, the unit needs replacement. You can temporarily silence the alarm using the ON/OFF switch.
Outlet does not fit flush in boxObstruction in box; Improperly seated wires.Ensure wires are neatly folded into the box. Check for any debris or obstructions. Ensure mounting ears are properly aligned.

9. Specificații

AtributDetaliu
MarcaPe-Q
Model36456902V1
CuloareAlb
MaterialMetal
Dimensiuni produs (L x l)7.3 cm x 3.4 cm
Prize de putere totală2
Voltage125 volți
Ampepoca15 Amps
Tehnologia de conectivitateCablat
Protecție la supratensiune340 Jouli
Max Surge Capability24kA
Greutatea articolului1.2 lire sterline
CertificaricULus listat
Detailed dimensions of the surge-protected duplex outlet

Image 9.1: This image provides detailed dimensions of the surge-protected duplex outlet, including its length, width, and depth behind the strap.

10. Garanție și asistență

10.1. Informații despre garanție

This Legrand On-Q product is covered by a warranty for 12 luni de la data cumpararii. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the official warranty documentation provided with your product or contact Legrand On-Q customer service.

10.2. Asistență pentru clienți

For technical assistance, troubleshooting, or warranty claims, please contact Legrand On-Q customer support. Contact information can typically be found on the product packaging or the official Legrand On-Q website-ul.

When contacting support, please have your product model number (36456902V1) and date of purchase readily available.

© 2023 Legrand On-Q. All rights reserved.